3Com 3C16075 manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of 3Com 3C16075, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of 3Com 3C16075 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of 3Com 3C16075. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of 3Com 3C16075 should contain:
- informations concerning technical data of 3Com 3C16075
- name of the manufacturer and a year of construction of the 3Com 3C16075 item
- rules of operation, control and maintenance of the 3Com 3C16075 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of 3Com 3C16075 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of 3Com 3C16075, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the 3Com service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of 3Com 3C16075.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the 3Com 3C16075 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    S UPER S TACK ® 3 A DVA NCED RPS T YPE 3 P OWER M ODULE (3C 1 6075 ) I NSTALLATION G UIDE CAUTION: All insta lled T ype 3 Power M odules must ha ve a DC c able or a protect ive cover fitted on completion of installation. The T y pe 3 Powe r Mod ule is a UL lis ted acc e s sory for use only with the U L li sted A dvan ced RPS Chas sis. Thi s gu ide[...]

  • Page 2

    2 S UP E R S TACK ® 3 A D VANC ED RP S T YPE 3 P OWER M ODUL E (3C160 75) I NSTALLATI ON G UI DE Introduction The T ype 3 Power Modul e fi ts into the SuperStack 3 Advanced RPS Cha ssis (3C16071, 3 C16 071A, or 3C16071B ). The mod ule p rov ide s r edundant pow er from the Advanc ed RPS chassis to the SuperStack 3 Switch 4 900 Series. Y ou c an us[...]

  • Page 3

    S upe rSta ck 3 Ad vanc ed RP S Cha ssis Lo adi n g Limi tat ions 3 Supe r Stack 3 Adva nced R PS Ch as sis Loading Lim itation s WARNING : Do not ov erload the chassi s — refer to T able 1 “ Max imum Number of Advanc ed RPS Po wer Modul es per C hassi s ” to determine loadi ng limitati ons. It is import ant that the loadi ng limita ti o ns a[...]

  • Page 4

    4 S UP E R S TACK ® 3 A D VANC ED RP S T YPE 3 P OWER M ODUL E (3C160 75) I NSTALLATI ON G UI DE Figu r e 1 sh ows the r ear vi ew of a n Adva nced RPS c hassi s an d t he pow er module slot numbers to help you determin e which slots to u se for your T ype 3 M odules to mee t the permitted configurations detailed in T able 1. Fi gur e 1 A dvance d[...]

  • Page 5

    S upe rSta ck 3 Ad vanc ed RP S Cha ssis Lo adi n g Limi tat ions 5 Ta b l e 1 Maxim um Num be r of Adv ance d RP S Po we r Mo dule s pe r C hass is Con fig ur at ion T ype 1 60 W Mod ule ( 3C1 607 2) T ype 1 1 00 W Modu le ( 3C16073 ), Ty pe 2 (1 00 W) Module (3C16074), o r Ty pe 2A ( 100 W) Mod ule (3C1607 4A) Typ e 3 Module (325 W) (3C 16075) A [...]

  • Page 6

    6 S UP E R S TACK ® 3 A D V ANC E D RP S T YPE 3 P OWE R M O DULE (3C160 75) I NSTALLATI ON G UIDE S afety I nform atio n Y ou must r ead the foll owing safety informa tion befor e carry i ng out any installation o r removal of co m ponents, or any maintenance pr oce dures on the S uperStack 3 Advance d RPS. WAR NING: Warnings co nta i n d ire cti[...]

  • Page 7

    S afety Info rmation 7 ■ When you connect DC cabl es to a T y pe 3 Powe r Mo dule you must tighten the s cr e ws on al l D C cable c onn ectors w ith a sui table tool. ■ W hen c onnec ting a D C c able to the po wer m odul e, you m ust take of f the D-ty pe connector pr otective c ov er by r emoving the fixin gs w ith a suit able tool. Keep the[...]

  • Page 8

    8 S UP E R S TACK ® 3 A D V ANC E D RP S T YPE 3 P OWE R M O DULE (3C160 75) I NSTALLATI ON G UIDE CAUTION: Un d é faut f u gitif d ’ alimentation peut exister a u niveau du conne ctor su Powe r Module de T ype 3 lorsque ce module e st dans le ch assis RPS avanc é . Wic htige S ic herhe itsi nfo rmati onen Der Ein- und A usba u d er Anlage i s[...]

  • Page 9

    Installi n g the Power Mo dule 9 CAUTION: Wenn s ich das T yp e 3 P o wer M od ule i m A dvance d R PS Chassi s b efinde t ka nn es zu ein er E n e rgiege fahr am DC St ecker ko mme n . I nst al lin g t he Po we r M od ule CAUTION: Ne ver plug a ho t powe r module into the Adv a n ced RPS . Y ou m ay damage the powe r module. All ow sufficient time[...]

  • Page 10

    10 S UP E R S TACK ® 3 A D V ANC E D RP S T YPE 3 P OWE R M O DULE (3C160 75) I NSTALLATI ON G UIDE Con necting t he D C C ables St anda r d T y pe 3 Modu le DC Cabl e T o con nect a standa r d T yp e 3 Module DC cable (supplied with t h is module) to pr ovide red undancy to y our Sup erStack 3 u nit: 1 Ensure the T y pe 3 Power M odule is in the [...]

  • Page 11

    T echnical Info rmation 11 CAUTION: Do no t attempt to use a ‘ Y ’ cable to pow er t w o separa te SuperStac k 3 un its . The equipme nt m ay not ope rate. CAUTION: All DC cable screw s must be t i ghte ned with a sui table tool. T ech nic al In fo r ma t ion T r ou blesho oting If the LE Ds on the S u perStack 3 Advanced RPS Chassi s indica te[...]

  • Page 12

    12 S UP E R S TACK ® 3 A D V ANC E D RP S T YPE 3 P OWE R M O DULE (3C160 75) I NSTALLATI ON G UIDE Should you be unable to r ectify the p r oblem, consult your supplier with the fol lowing information: ■ Product numbe r and po we r modul e se rial num be r ■ Brief des cri ption of the fault Copy r ight © 20 00, 3Com T ec hno l ogie s. All ri[...]