Warning: mysql_fetch_array() expects parameter 1 to be resource, boolean given in /home/newdedyk/domains/bkmanuals.com/public_html/includes/pages/manual_inc.php on line 26
Tripp Lite Extended-Run Single-Phase Battery Cabinet manuale d’uso - BKManuals

Tripp Lite Extended-Run Single-Phase Battery Cabinet manuale d’uso

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Vai alla pagina of

Un buon manuale d’uso

Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Tripp Lite Extended-Run Single-Phase Battery Cabinet. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Tripp Lite Extended-Run Single-Phase Battery Cabinet o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.

Che cosa è il manuale d’uso?

La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Tripp Lite Extended-Run Single-Phase Battery Cabinet descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.

Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.

Quindi cosa dovrebbe contenere il manuale perfetto?

Innanzitutto, il manuale d’uso Tripp Lite Extended-Run Single-Phase Battery Cabinet dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Tripp Lite Extended-Run Single-Phase Battery Cabinet
- nome del fabbricante e anno di fabbricazione Tripp Lite Extended-Run Single-Phase Battery Cabinet
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Tripp Lite Extended-Run Single-Phase Battery Cabinet
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti

Perché non leggiamo i manuali d’uso?

Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Tripp Lite Extended-Run Single-Phase Battery Cabinet non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Tripp Lite Extended-Run Single-Phase Battery Cabinet e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Tripp Lite in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Tripp Lite Extended-Run Single-Phase Battery Cabinet, come nel caso della versione cartacea.

Perché leggere il manuale d’uso?

Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Tripp Lite Extended-Run Single-Phase Battery Cabinet, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.

Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Tripp Lite Extended-Run Single-Phase Battery Cabinet. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.

Sommario del manuale d’uso

  • Pagina 1

    1. Introduction 2 2. Important Safety Instructions 3 3. Battery Cabinet Installation 5 3.1 Preparation 5 3.2 T ranspor tation 5 3.3 Mechanical Check 5 3.4 Internal Wiring (T ypical) 6 3.5 Preliminary Electrical Check 6 3.6 Battery Cabinet Placement 6 3.7 Electrical Connection 7 3.8 Battery Charger Electrical Connection (Select Models) 7 3.9 Final E[...]

  • Pagina 2

    2 1. Introduction T ripp Lite’ s Extended-Run Single-Phase Battery Cabinets connect to SmartOnline 3-Phase UPS Systems to provide long-lasting battery backup for data centers, telecommunications, networks, industrial facilities, security , emergency systems and other mission- critical applications that require high capacity , high availability an[...]

  • Pagina 3

    3 2. Important Safety Instructions SA VE THESE INSTRUCTIONS All sections of this manual contain instructions and warnings that must be followed during the installation and operation of the battery cabinet described in this manual. Read ALL instructions thoroughly before attempting to move, install or connect your battery cabinet. Failure to comply [...]

  • Pagina 4

    4 2. Important Safety Instructions ( continued ) Battery W arnings The battery cabinet does not require routine maintenance by the user . There are no user-serviceable parts inside. Only • qualied, knowledgeable service personnel familiar with all required precautions should open the access panels for any reason. Keep unauthorized personnel[...]

  • Pagina 5

    5 3.1 Preparation 3.2 T ransportation 3.3 Mechanical Check 3. Battery Cabinet Installation Read Section 2 – Important Safety Instructions Before Installation At your site, prepare to off-load the battery cabinet from the delivery truck and transport it to the nal installation location. • Consider both the packaged weight and dimensions. A[...]

  • Pagina 6

    6 3.4 Internal Wiring (T ypical) 3.5 Preliminary Electrical Check 3.6 Battery Cabinet Placement 3. Battery Cabinet Installation ( continued ) Battery cabinets use multiple 12 VDC batteries connected in series to provide nominal DC voltages ranging from 192 VDC • to 240 VDC. Internal cabling is sized for specic application load currents. The[...]

  • Pagina 7

    7 3.7 Electrical Connection 3.8 Battery Charger Electrical Connection (Select Models) 3.9 Final Electrical Check 3. Battery Cabinet Installation ( continued ) The battery cabinet should be connected to the load through a DC disconnect switch or a DC circuit breaker . This allows the • battery to be disconnected from the load and charger for ma[...]

  • Pagina 8

    8 Additional battery strings can be daisy-chained to the UPS internal battery system via a unique connector inside the UPS battery compartment (Figure 3.10a). A 15-ft. BP240EXTNDR15DL cable is required to connect the rst battery cabinet to the UPS system (Figure 3.10b). Cabling for all additional built-to-order cabinet installations is the sole [...]

  • Pagina 9

    9 4. Operation and Charging 4.1 Determine Charging V oltages 4.2 Initial Charge 4.3 Operational Check 4.4 Acceptance T est (Optional) T o determine the appropriate equalization (freshening) charge voltage and oat char ge voltage, multiply the number of batteries connected in series in the battery cabinet by the recommended charging voltage per u[...]

  • Pagina 10

    10 5. Maintenance 5.1 Maintenance Schedule 5.2 Fuse Replacement Quarterly Check Measure individual battery unit temperature. (Measure with a digital thermometer by placing the surface thermocouple on 1. the at surface of the negative terminal—not the “L” connection surface. An infrared temperature monitor can also be used. T emperatures be[...]

  • Pagina 11

    11 6.1 Battery Cabinet Diagram (3 Shelves) 6. Diagrams Note : All dimensions are in inches. 28.80 6.00 32.4 6.00 3.25 4.50 4.50 4.00 3.50 10.58 13.50 2.25 15.75 60.00 13.50 13.50 15.40 8.25 11.00 16.00 AC Input for Battery Charger Breaker Mounting Plate 14.50 29.00 Battery Charger Battery Charger Battery Charger[...]

  • Pagina 12

    12                     Shelf 2 Shelf 3 Shelf 1 (Bottom ) To Fuse or [...]

  • Pagina 13

    13 6.3 Integrated Battery Charger (Select Models) 6. Diagrams ( continued ) 6.25 MAX 0.5 12.5 13.5 Notes : • All dimensions are in inches. • AC input is preset with fuses for 120V 30 A, but can be rewired for 208 and 240 V AC, 60 Hz by a qualied electrician. • Constant voltage output. • Electronic current limiting and high voltage shutdo[...]

  • Pagina 14

    14 7.1 Dimensions and Floor Loading 7.2 Recommended T orque 7. Specifications Battery Cabinet Model Shelves Dimensions (Width x Depth x Height) Weight Floor Loading BP240V557C-1PH 3 32.4 x 28.8 x 60 inches (82.3 x 73.2 x 152.4 cm) 1250 lb (567.5 kg) 193 lb/ft 2 (943 kg/m 2 ) BP240V787C-1PH 3 32.4 x 28.8 x 60 inches (82.3 x 73.2 x 152.4 cm) 1850 lb[...]

  • Pagina 15

    15 9. W arranty 8. Storage and Service Storage The battery cabinet must be stored in a clean, secure environment with a temperature less than 40° C (104° F) and a relative humidity less than 90% (non-condensing). Store the battery cabinet in its original shipping container if possible. Charge the batteries for at least 24 hours prior to use. Do n[...]

  • Pagina 16

    200809068 93-2847 1 1 1 1 W . 35th Street, Chicago, IL 60609 USA +1.773.869.1234 • www .tripplite.com[...]