Warning: mysql_fetch_array() expects parameter 1 to be resource, boolean given in /home/newdedyk/domains/bkmanuals.com/public_html/includes/pages/manual_inc.php on line 26
Lantronix 900-371 manuale d’uso - BKManuals

Lantronix 900-371 manuale d’uso

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109

Vai alla pagina of

Un buon manuale d’uso

Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Lantronix 900-371. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Lantronix 900-371 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.

Che cosa è il manuale d’uso?

La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Lantronix 900-371 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.

Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.

Quindi cosa dovrebbe contenere il manuale perfetto?

Innanzitutto, il manuale d’uso Lantronix 900-371 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Lantronix 900-371
- nome del fabbricante e anno di fabbricazione Lantronix 900-371
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Lantronix 900-371
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti

Perché non leggiamo i manuali d’uso?

Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Lantronix 900-371 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Lantronix 900-371 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Lantronix in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Lantronix 900-371, come nel caso della versione cartacea.

Perché leggere il manuale d’uso?

Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Lantronix 900-371, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.

Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Lantronix 900-371. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.

Sommario del manuale d’uso

  • Pagina 1

    Part Number 900-371 Revision C January 2009 SecureLinx TM SLP Remote Power Manager User Guide[...]

  • Pagina 2

    [...]

  • Pagina 3

    Copyright & Trademark © 2004, 2006 Lantronix. All rights reserved. No part of the content s of this book may be transmitted or reproduc ed in any form or by any means without the written permission of Lantronix. Printed in the United States of America. Ethernet is a trademark of XEROX Corporati on. UNIX is a registered trademark of The Open Gr[...]

  • Pagina 4

    Life-Support Policy As a general policy, Lantronix does not recom mend the use of any of its products in the following situations:  Life-support applications where failure or malfunction of the Lantronix product can be reasonably expected to cause f ailure of the life-support device or to significantly a ffect its sa fety or effectiveness.  D[...]

  • Pagina 5

    Contents 1: Introduction 7 Features and Benefits ________________________________________________ 7 Communication A ccess Modes _____________________________________________ 7 Power Distribution _______________________________________________________ 7 Load and Environment Measu rement ________________________________________ 7 Power-up Sequencing [...]

  • Pagina 6

    Contents Command Line Interface _____________________________________________ 33 Logging In _____________________________________________________________ 33 Operations Commands ___________________________________________________ 36 Administration Commands ________________________________________________ 42 4: Advanced Operations 65 SSL ____________[...]

  • Pagina 7

    Contents List of Figures Figure 2-1. SLP Hardware View________________________________________ 10 Figure 2-2. Retention Bracket Assembly _________________________________ 11 Figure 3-1. Web Browser Interface _____________________________________ 15 List of Tables Table 3-1. Outlet State/C ontrol State Field Values _________________________ 16 Table[...]

  • Pagina 8

    1: Introduction The Lantronix SLP Remote Power Ma nager family of products provides easy, practical, and secure soluti ons for pow er distribution, power management and load- measurement for remote equipment and bran ch AC circuits. The SLP Remote Power Manager sup ports the elimination of unnece ssary trips to remote locations by allowing rem ote [...]

  • Pagina 9

    1: Introduction When powered on, each of the power o utl ets power sequentially with a two-second delay between each outlet. Power sequenc ing staggers the individual loa ds, eliminating the potential of a blown fuse or circuit breaker due to exce ssive in-rush current and allows circuit support for operating lo ad capacities of 80% to 90%. Outlet [...]

  • Pagina 10

    2: Installation Prior to installation, refer to the following lists to ensure that you have all the items shipped with the unit as wel l as all other items required for prop er installation. Standard Accessories  Mounting bracket hardware: Vertical (SLP-V, SLPY* models) – two re movable flanges with four M4 screws and two mounting L-brackets w[...]

  • Pagina 11

    2: Installation Figure 2-1. SLP Hardw are View Output Power Status LED RS-232 Serial (RJ45) Outlet Input Current LED RJ12 Link Connectors for Optional Temperature/Humidity Sensor 10/100Base-T Ethernet (RJ45) Connectors for Optional Temperature/Humidity Sensor RS-232 Serial (RJ45) ) AC Power Inlet Outlet Input Current LED 10/100Base-T Ethernet (RJ45[...]

  • Pagina 12

    2: Installation Always disconnect the power suppl y cord before opening to avoid e lectrical shock. Warning! High leakage current ! Earth connection is essential before connectin g supply! Warning: 208-240/230V mod els only: Outlets are not fused. Outlet circuit protection is provided by the building i nstallation, which s hall not exceed 30A branc[...]

  • Pagina 13

    2: Installation Connecting to the Power Source Attach the power cord to the unit before con necting the unit to the power source. Each outlet powers up sequentially, with a two-second delay between each outlet, eliminating a potential blown primary fuse or circuit breaker from exce ssive in-rush current. To attach a power cord to the unit: 1. Plug [...]

  • Pagina 14

    2: Installation The following network defaults allow unit configuration out-of-the-box through either Telnet/SSH or via a web browser: IP address: 192.168.1.254 Subnet Mask: 255.255.255.0 Gateway: 192.168.1.1 The local PC network conn ection must be configured as Noted below: Note: Contact your system adm inistrator fo r instructions in reconfiguri[...]

  • Pagina 15

    3: Operations User Interfaces Two user interfaces are available: t he web browse r interface accessed via the HTTP/SSL enabled Ethernet connections and the co mmand line for serial and Telnet/SSH connections. Outlet Naming and Grouping For commands requiring a n outlet name, you may specify it in one of two ways: a predefined absolute name or a des[...]

  • Pagina 16

    3: Operations used to display current data and allow changes to out let states or system configuration. Figure 3-1. Web Brow ser Interface The following sections d escribe each interface section/page and th eir use. Logging In Logging in via a web browser requires directing the web client to the configure d IP address of the unit. To log in by web [...]

  • Pagina 17

    3: Operations Available outlet and group power states may be set to on, off or reboot; the reboot operation turns the outlet(s) off, delays fo r a period of 15 sec onds and then turns the outlet(s) on. Individual The Individual outlet control page displays all outle ts assigne d to the current user. The user may apply on, off or reboot actions to i[...]

  • Pagina 18

    3: Operations Outlet State Control State Description of outlet status required On/Error varies Error State – Outlet should be off but current is sensed at the outlet Off/Error varies Error State – Outlet should be on but no current is sensed at the outlet Off/Fuse On Outlet should be on but a blown fuse has been detected. No Comm varies Communi[...]

  • Pagina 19

    3: Operations 1. Select Normal or Inverted from the drop-down menu and press Apply . Enabling or disabling strong password requirements : 1. The SLP supports enforcement of strong passwords for enhanced security. When enabled, all new passwords mu st be a minimum of 8 characters in length with at least one uppercase letter, one lowerca se letter, o[...]

  • Pagina 20

    3: Operations Creating a descriptive outlet nam e: 1. Click on the Outlet Names link which will open the Outlets configuration page . See Outlets on page 22 for additional informatio n on creating descriptive outlet names. Creating a descriptive serial port nam e: 1. Click on the Serial Port Names link which will open the Serial Port configuratio n[...]

  • Pagina 21

    3: Operations Telnet/SSH The Telnet/SSH configuration page is used to enable or disable Telnet and SSH support and configure the port number that the Telnet or SSH server wat ches. For more information on SSH see Advanced Operations on page 66 . Enabling or disabling Telnet or SSH support: 1. Select Enabled or Disabled from the appro priate Server [...]

  • Pagina 22

    3: Operations Note: The default port number for HTT P is 80. Setting the HTTP authentication method : The HTTP server supports two authe nticat ion methods for security and validation of the username-passwo rd – Basic and MD5 digest. The Basic method utilizes Base6 4 encoding to encode and delive r the username- password over the network to the H[...]

  • Pagina 23

    3: Operations 2. On the subsequent Serial Port Edit page, enter the descriptive name. Up to 24 alphanumeric and other typeable chara cters (ASCII 33 to 126 decimal, spaces and colon characters are not allowed) are allowe d. Press Apply . Note: Port names ‘ 1’ thru ‘64’ and ‘CONSOLE’ are re served system nam es and may not be used. Enabl[...]

  • Pagina 24

    3: Operations 1. Enter a descriptive group name in the Group Name field. Up to 24 alphanumeric and other typeable characters (ASCII 33 to 126 decimal, spaces and colo n characters are not allowed) are allowed. Press Apply . Removing a group: 1. Click on the Remove link in the Action colum n for the group to be removed and press Yes on the subsequ e[...]

  • Pagina 25

    3: Operations assigned outlets, groups and se rial/Pass-Thru port s.  On-Only: Partial-acces s for contro l (On) , status and Pass-Thru of assigned outlets, groups and se rial/Pass-Thru port s.  View-Only: Partial-access for status and Pass-Thru of assigned outlets, groups and serial/Pass-Thru ports. The administrator may also grant administr[...]

  • Pagina 26

    3: Operations 1. Enter the FTP server username in the Username field, and pre ss Apply . Setting the FTP password: 1. Enter the FTP server password in the Password field, and press Apply . Setting the file path: 1. Enter the path of the file to be upl oaded in the Directory field, and press Apply . Setting the filename for upload: 1. Enter the file[...]

  • Pagina 27

    3: Operations 1. Enter the IP address or hostname in the Primary and/or Secondary Host field and press Apply . Setting the Local GMT offset: 1. Select the local offset from GMT value from the drop-down menu and press Apply . Setting the Syslog server address: 1. Enter the IP address or hostname in the Primary and/or Secondary Host field and press A[...]

  • Pagina 28

    3: Operations 1. In the appropriate field, enter the SysN ame, SysLocation or SysContact objects and press Apply . Enabling or disabling tower (unit) tra ps: 1. Click on the Tow er Traps link. 2. On the subsequent page, select or deselect the desired traps and press Apply . Configuring input feed traps: 1. Click on the Input Feed Traps link. 2. On [...]

  • Pagina 29

    3: Operations Changing the LDAP server port: 1. Enter the port number in the LDAP Port field and press Apply . Setting the LDAP server address: 1. Enter the IP address or hostname in the Primary and/or Secondary Host field and press Apply . Note: If LDAP over TLS/SSL is enabl ed , MD5 binding is disabled. Enabling or disabling LDAP over TLS/SSL: 1.[...]

  • Pagina 30

    3: Operations Configuring LDAP groups: 1. Click on the LDAP Groups at the bottom of the page. Creating an LDAP group : 1. Enter a descriptive group name in the LDAP Group Name field. Up to 24 alphanumeric and other typeable chara cters (ASCII 33 to 126 decimal) are allowed; spaces are not allowed. Press Apply . Removing an LDAP group: 1. Click on t[...]

  • Pagina 31

    3: Operations 1. Select Enabled or Disabled from the T ACACS+ drop-down menu and press Apply . Setting the TACACS+ serv er address: 1. Enter the IP address or hostname in the Primary and/or Secondary Host field and press Apply . Changing the TACACS+ serv er port: 1. Enter the port number in the Port field and press Ap ply . Configuring the authenti[...]

  • Pagina 32

    3: Operations 4. On the subsequent LDAP Group-Outlets page, sele ct or deselect outlets to be accessed by the TACACS+ Privilege Level and press Apply . Adding and Deleting outlet group a cc ess: 3. Click on the Outlets link in the Action column for the associated T ACACS+ Privilege Level. 4. On the subsequent LDAP Group-Groups page, select or desel[...]

  • Pagina 33

    3: Operations Ping The Ping feature may be used to test the SL P’s ability to contac t another Ethernet enabled device’s IP address. Fo r LDAP support, it may also be used to test the configuration of the Domain Name se rver IP address by testing for proper name resolution. Change Password The Change Password feat ure allo ws users to change th[...]

  • Pagina 34

    3: Operations Select the Restart and generate a ne w X.509 certificate from the Action drop-down menu and press Apply . Computing new SSH security keys: 1. Select the Restart and compute new SSH key s from the Action drop-down menu and press Apply . Command Line Interface Logging In Logging in through Telnet/SSH require s directing the Telnet/SSH c[...]

  • Pagina 35

    3: Operations You may enter commands in any combination of uppercase and lo wercase. You must enter all command characters correct ly; there are no comm and abbreviations. There are two types of commands: operati ons and administ ration. A user must have administrative privileges to use the ad minis tration commands. The following tables list and b[...]

  • Pagina 36

    3: Operations Command Description Set FTP Autoupdate Hour Set the automatic FTP udate hour Set FTP Directory Specifies the directory for the file to be upload ed Set FTP Filename Specifies the file to be uploaded via F TP Set FTP Filepath Specifi es the file path for the file to be uploaded Set FTP Host Sets the FTP Host IP address Set FTP Password[...]

  • Pagina 37

    3: Operations Command Description Show Network Display network configur ation information Show Outlets Displays configuration information for all outlets Show Ports Displays the serial port configuration information Show System Displa ys system configuration information Show Towers Displays unit configuration informatio n Version Displays the firmw[...]

  • Pagina 38

    3: Operations Examples The following command turns the second outlet on, using the o utlet’s absolute name: SLP: on .a2<Enter> The following command turns on all the outlets in the group named ServerGrou p_1: SLP: on ServerGroup_1<Enter> Turning outlets off The Off command turns off one or more outlets. When the command completes, a d[...]

  • Pagina 39

    3: Operations Displaying outlet status The Status command displays the on/off status of one or more out lets. The command displays the status of only tho s e outlets for which the current username has power control access. This display includes the outlet absol ut e and descriptive names, the Outlet State reported to the unit by the outlet and the [...]

  • Pagina 40

    3: Operations SLP: status ServerGroup_1<Enter> Group: ServerGroup_1 Outlet Outlet Outlet Control ID Name State State .A1 DataServer_1 On On .A2 WebServer_1 On On .A3 FileServer_1 On On Displaying accessible outlets The List Outlets command display s accessible outlets for the current user. The display includes the absol ute and descript ive n[...]

  • Pagina 41

    3: Operations ID Name .A1 DataServer_1 .A2 WebServer_1 .A3 FileServer_1 Displaying accessible serial ports The list ports command di splays accessible serial ports for the current use r. To display accessible serial ports: 1. At the SLP prompt, type list ports and press Enter . Example The following command display s all accessible serial ports for[...]

  • Pagina 42

    3: Operations Displaying the status of the Environmental Moni tor: The Envmon command displays the stat us of the integrated Environmental Monitor. By default, only administrative user acco unts are allowed acce ss to the Envmon command. An administrator may user t he Set User Envmon command to enab le and disable access for other user a ccounts. T[...]

  • Pagina 43

    3: Operations Administration Commands Administration commands may only be issued by a u ser with administrative privileges, such as the predefined a dminist rative account or another user who h as been granted administrative privileges with the Set User Admnp riv command. User Administration Creating a user account The Create User command creates a[...]

  • Pagina 44

    3: Operations 3. At the Verify Password prompt, retype the new password and press Enter . Examples The following command ch anges the password for the use r JohnDoe: SLP: set user password johndoe<Enter> Password: <Enter> Verify Password: <Enter> Setting user access level privileges The Set User Access command sets the access leve[...]

  • Pagina 45

    3: Operations The following command di splays all users with their access privilege level: SLP: list users<Enter> User Privilege Environmental Name Level Monitoring JOHNDOE Admin Allowed JILLDOE Power-User Allowed JANEDOE User Allowed JAKEDOE Reboot-Only Not Allowed JOSEYDOE On-Only Not Allowed JOEDOE View-Only Not Allowed Adding outlet acces[...]

  • Pagina 46

    3: Operations SLP: add GroupToUser ServerGroup_1 janedoe<Enter> SLP: add GroupToUser ServerGroup_2 janedoe<Enter> Deleting group access fo r a user The Delete GroupFromUse r command removes a user’s a ccess to a group. You cannot remove access to any group fo r an administrative level user. To delete group access for a user: 1. At the[...]

  • Pagina 47

    3: Operations JaneDoe may access the following outlets and g roups: outlet A1 which has a descriptive name of DataServer_1, outle t A2 which has a descriptive name of WebServer_1, group ServerGroup_1, group ServerGr oup_2, and Console serial port. Outlet Administration Setting the sequencing interval The Set Outlet SeqInterval command sets the powe[...]

  • Pagina 48

    3: Operations Example The following command se ts the wakeup state for outlet .a1 to off: SLP: set outlet wakeup off .a1<Enter> Setting the outlet Post-On delay The Set Outlet PostOnDelay command sets the Po st-On delay for an outlet. This feature allows and administrator to ma nage boot dependencies d uring power-on sequencing or gro up comm[...]

  • Pagina 49

    3: Operations G r o SLP: show outlets<Enter> Outlet Outlet Wakeup Post-On ID Name State Delay seconds) u p .A1 TowerA_Outlet1 On 0 .A2 TowerA_Outlet2 On 0 .A3 TowerA_Outlet3 On 0 A .A4 TowerA_Outlet4 On 0 d .A5 TowerA_Outlet5 On 90 m .A6 TowerA_Outlet6 On 0 .A7 TowerA_Outlet7 On 0 i .A8 TowerA_Outlet8 On 0 n .A9 TowerA_Outlet9 On 0 .A10 Tower[...]

  • Pagina 50

    3: Operations Adding an outlet to a group The Add OutletToGroup command add s an outlet to a group. To add more than one outlet, but not all outlets, you must use multiple Add OutletToGroup commands. To add an outlet to a group: 1. At the command prompt, type add outlettogroup , optionally followed by an outlet name and group name. Press Enter , or[...]

  • Pagina 51

    3: Operations Example The following command ad ds the descript ive name DataServer_1 to outlet .a1: SLP: set outlet name .a1 DataServer_1<Enter> Setting the outlet wakeup state The Set Outlet Wakeup command set the defaul t wakeup state fo r that outlet. In the event of a system-wid e power loss, this state will be a pplied to the outlet when[...]

  • Pagina 52

    3: Operations .A16 on More (Y/es N/o): Serial Port Administration Creating a descriptive serial port nam e The Set Port Name command assi gns a descriptive name to a serial port. You may use this name in commands that re quire a port name as an alternative to using the port’s absolute name. To create a port name: 1. At the command prompt, type se[...]

  • Pagina 53

    3: Operations Setting the serial port timeout value The Set Port Speed Timeout command is used to set the seri al port inactivity timeout period. The timeout period defines the maximum perio d of inactivity before automatically closing the session. The va lid range for the period parameter is 0 to 5 (in minutes). The default period is 5. Note: Sett[...]

  • Pagina 54

    3: Operations 2. At the command prompt, type set banner and press Enter . Type the desired pre-login banner text and whe n finished type Ctrl-z. Creating a location description The Set Location command specifie s text that appears in the web browser control screen’s Location field. The text is also appended to a “Welcome to” ban ner that appe[...]

  • Pagina 55

    3: Operations H/W Rev Code: 0 Flash Size: 1 MB Uptime: 0 days 6 hours 14 minutes 1 second Location: Florida HQ Setting the LED display orientation The Set Option Display command is used to configure the Current LED(s) di splay orientation. To set the LED display orientation: 1. At the command prompt, type set option display , followed by normal or [...]

  • Pagina 56

    3: Operations 1. At the command prompt, type set option more , followed by enable d or disabled and press Enter . Setting the temperature scale The Set Option TempScale command sets the tempe rature scale that the SLP will report in. To set the temperature scale: 1. At the command prompt, type set option tempscale , followed by Celsius or Fahrenhei[...]

  • Pagina 57

    3: Operations 1. At the command prompt, type show units and press Enter . Example SLP: show units<Enter> Unit Unit ID Name .A Florida_HQ_1 Creating a descriptive infeed name The Set Infeed Name command assi gns a descriptive name to an infeed. This descriptive name is displayed when the Show Traps comm and is issued. See Displaying trap confi[...]

  • Pagina 58

    3: Operations Example The following command ad ds the descriptive name Florida__ HQ_1 to tower .a: SLP: set tower name .a Florida_HQ_1<Enter> Displaying Tower information The Show Towers command displays informat ion about the SLP. This information includes the absolute and descriptive SLP names. To display unit information: 1. At the command[...]

  • Pagina 59

    3: Operations 1. At the command prompt, type set ipaddress , followed by the IP address and press Enter . Example The following command sets the IP address to 12.34. 56.78: SLP: set ipaddress 12.34.56.78<Enter> Setting the subnet mask The Set Subnet command sets the subnet mask for the network in which the unit will be attached. To set the su[...]

  • Pagina 60

    3: Operations To enable or disable automatic updates: 1. At the command prompt, type set ftp autoupdate , followed by enabled or disabled and press Enter . Setting the automatic update sched uled day The Set FTP Autoupdate Day command is used to set the day when automatic updates occur. To set the automatic update day : 1. At the command prompt, ty[...]

  • Pagina 61

    3: Operations SLP: set sntp primary 204.152.184.72<Enter> The following command se ts the secondary SNTP server add ress to cuckoo.nevada.edu: SLP: set sntp secondary cuckoo.nevada.edu<Enter> Setting the local GMT offset The Set SNTP GMT offset command is used to set the offset from GMT for the date/time returned by SNTP. The offset can[...]

  • Pagina 62

    3: Operations 2. At the command prompt, type show network and press Enter . Example The following command display s the network configuration information: SLP: show network<Enter> Network Configuration IP Address: 12.34.56.78 Subnet Mask: 255.0.0.0 Gateway: 12.34.56.1 Telnet: Enabled Port: 23 SSH: Enabled Port: 65535 HTTP: Enabled Port: 80 Se[...]

  • Pagina 63

    3: Operations 1. At the command prompt, type set http security , followed by basic or md5 and press Enter . Telnet Administration Note: A restart of the unit is required after setting or changing ANY Telnet/Web configurations. See Performing a warm boot on page 57 for m ore inform ation . Enabling and disabling Telnet support The Set Telnet command[...]

  • Pagina 64

    3: Operations Setting the FTP username The FTP Username command sets the username as required by the FTP Ho st. To set the FTP username: 1. At the command prompt, type set ftp username , followed by the FTP username and press Enter . Example The following command sets the FTP userna me to Guest: SLP: set ftp username guest<Enter> Setting the [...]

  • Pagina 65

    3: Operations Displaying FTP configuration information The Show FTP command displays all FTP configu ration information. FTP Host IP address FTP Host username and password Firmware file path and filename To display FTP configuration information: 1. At the command prompt, type show ftp and press Enter . Example The following command display s the FT[...]

  • Pagina 66

    4: Advanced Operations SSL Secure Socket Layers (SSL) version 3 enables secure web bro wser sessions between a Remote Power Manager and a remote user. SSL provides two chi ef features designed to make TCP/IP (Int ernet) tran smitted data more secure:  Authentication – The connecting client i s assured of the identity of the server.  Encrypt[...]

  • Pagina 67

    4: Advanced Operations To change the access lev el: 1. At the command prompt, type set ssl access , followed by optional or required , and press Enter . Example The following change s the access level to required: SLP: set ssl access required<Enter> SSL Technical Specifications Secure Socket Layer (SSL) version 3 Transport Layer Security (TLS[...]

  • Pagina 68

    4: Advanced Operations Enabling and Setting up SSH Support Note: A restart of the unit is required after setting or changing ANY SSH configurations. See Performing a warm boot on page 57 for m ore inform ation . Enabling or disabling SSH support The Set SSH command is used to enable or disable S SH support. To enable or disable SSH support: 1. At t[...]

  • Pagina 69

    4: Advanced Operations SNMP The SLP family of products supports t he Simple Netw ork Management Protocol (SNMP). This allows network mana gement systems to use SNMP requests to retrieve information and control power for the individ ual outlets. The SNMP implementation includes an SNMP v1 agent supporting standard MIB I and MIB II objects. A private[...]

  • Pagina 70

    4: Advanced Operations SLP: set snmp trapdest1 64.42.31.208<Enter> The following sets the trap destination 2 to snmp.lantronix.com: SLP: set snmp trapdest2 snmp.lantronix.com <Enter> To reset the trap destinat ion: 1. At the command prompt, type set snmp , trapdest1 or trapdest2 , 0.0.0.0 and press Enter . Setting the trap timer The Set[...]

  • Pagina 71

    4: Advanced Operations Setting SNMP IP Restrictions The Set SNMP IP Restrictions comm and supports SNMP Mana ger GET and SET requests to only be allowed from the IP addresses of the defined traps destinations. To set SNMP IP Restrictions: 1. At the command prompt, type set snmp iprestrict trapdests and press Enter . To remove SNMP IP Restrictions: [...]

  • Pagina 72

    4: Advanced Operations SNMP suppor t status SNMP communit y strings Trap timer value Trap destinations To display SNMP configuration information: 1. At the command prompt, type show snmp and press Enter . Example The following command di splays the SNMP configuration information: SLP: show snmp<Enter> SNMP Configuration SNMP: Enabled SET Comm[...]

  • Pagina 73

    4: Advanced Operations Status trap A Status trap is generated when an error condition o ccurs on a unit, infeed or outlet. Status traps include the reported Status, the Location of the unit, and identifier and name of the affected unit, infeed or outlet. Any Trap Status generates a Status trap and triggers the trap timer. A new trap is generated at[...]

  • Pagina 74

    4: Advanced Operations Load Trap The Load trap is generated whenever t he total input load on an infeed exceeds a preset threshold. Load traps in clude the r eported input load, load status, Locat ion of the unit, and identifier and name of the affected infeed. Any error state generate s a Load trap and triggers the trap timer. A new trap is genera[...]

  • Pagina 75

    4: Advanced Operations The following command enable s the Status trap using the unit’s absolute name: SLP: set trap unit status .a on<Enter> The following command enable s the Status trap for the unit named Florida_HQ_1: SLP: set trap unit status Florida_HQ_1 on<Enter> Note: Enabling lower hierarchical trap s autom atically enables tr[...]

  • Pagina 76

    4: Advanced Operations To Enable or Disable a Change trap: 4. At the command prompt, type set trap outlet change , followed by the outlet name and on or off . Press Enter , or 5. Type set trap outlet change all , followed by on or off and press Enter . SecureLinx SLP Remote Power Man ager 75[...]

  • Pagina 77

    4: Advanced Operations Example The following command en ables the Change trap for the third outlet using the ou tlet’s absolute name: SLP: set trap outlet change .a3 on<Enter> Displaying trap configuration information The Show Traps command displ ays information about all traps. To display trap information: 1. At the command prompt, type sh[...]

  • Pagina 78

    4: Advanced Operations SLP LDAP support has been tested in the followin g environments: • Microsoft Active Directory (MSAD) • Novell eDirectory (eDi r) • OpenLDAP LDAP Command Summary Command Description Set Authororder Specifies the authentic ation order for each ne w session attempt Set LDAP Enables/disables LDAP support Set LDAP Host Sets [...]

  • Pagina 79

    4: Advanced Operations Add PorttoLDAP Grants an LDAP group a ccess to one or more serial ports Delete GroupfromLDAP Removes access to one or more groups for an LDAP group Delete OutlettoLDAP Removes access to one or more outlets for an LDAP group Delete PortfromLDAP Removes access to one or more serial ports for a n LDAP group Set LDAPGroup Access [...]

  • Pagina 80

    4: Advanced Operations 1. At the command prompt, type set ldap , followed by host1 or host2 and the Directory Services server’s IP address or hostname. Press Enter . Examples The following command sets the prima ry Directory Services server IP addres s to 98.76.54.32: SLP: set ldap host1 98.76.54.32<Enter> The following command di sables th[...]

  • Pagina 81

    4: Advanced Operations Note: Windows 2000 i s known only to support Simple bindin g. Windows 2003 supports both Simple and MD5 bin ding. To set the bind pass word ty pe: 1. At the command prompt, type ldap bind , followed by simple or md5 and press Enter . Note: If MD5 binding is enabled, LDAP over TLS/SSL is disable d. Setting the search bind Dist[...]

  • Pagina 82

    4: Advanced Operations Memberof<Enter> Setting the group membership value type: The Set LDAP GroupType comma nd is used to specify whether the values of group Membership Attribute represent the Dist ingui shed Name (DN) of a group or just the name of the group. To set the group membership value type: 2. At the command prompt, type ldap groupt[...]

  • Pagina 83

    4: Advanced Operations Displaying the LDAP configuration information: • The Show LDAP command displays LDA P configuration information • Enabled-disabled status of LDAP sup port • Directory Services server IP addres s and port • Bind request password type and remote authentication orde r • Search bind distinguished name and pa ssword • [...]

  • Pagina 84

    4: Advanced Operations SLP: set dns1 98.76.54.254<Enter> Verifying the DNS configuration: The Ping command may be used to verify the configuration of the DNS IP address. To verify the DNS configuration: 1. At the command prompt, type ping followed by the domain component of the Directory Services server previously configured and press Enter. [...]

  • Pagina 85

    4: Advanced Operations View—Only. For more information on user access levels, se e Changing a user’s access privilege level : on page 17. To set the access level privilege for a n LDAP group: 1. At the command prompt, type set ldapgroup access, followed by admin, user, ononly or viewonl y , optionally followed by a LDAP a group name. Press Ente[...]

  • Pagina 86

    4: Advanced Operations The Add OutletToLDAP command grant s an LDAP group access to one or all outlets. To grant access for more than one outlet, but not all outlets, you must use m ultiple Add OutletToLDAP commands. To grant outlet access to an LDAP gro up: 1. At the command prompt, type add outlettoldap, optionally followed by an outlet name and [...]

  • Pagina 87

    4: Advanced Operations The Add PortToLDAP command g rants an LDAP group access to the seri al port. To grant serial port access to an LDAP group: 1. At the command prompt, type add porttoldap console and a group name . Press Enter. Deleting serial port access for an L DAP group The Delete PortFromLDAP command removes an LD AP group’s access to th[...]

  • Pagina 88

    4: Advanced Operations TACACS+ Command Summar y Command Description Set Authorder Specifies the authentication order for each new session attempt Set TACACS Enables/disables SSL support Set TACACS Host Sets the IP address or hostname of the TACACS server Set TACACS Key Sets the TACACS encryption key Set TACACS Port Sets the TACACS server port numbe[...]

  • Pagina 89

    4: Advanced Operations The following command se ts the secondary TACACS+ se rver address to tacacs.lant ronix.com: SLP: set tacacs host2 tacacs.lantronix.com<Enter> Setting the TACACS+ encry ption key : The Set TACACS Key command sets the encryption key used to encrypt all data packets between the SLP and the TACACS+ server. This key must mat[...]

  • Pagina 90

    4: Advanced Operations The Remote Only method attempts authent icatio n only with the TACACS+ serve r and if unsuccessful, access is denied. Note: With the Remote On ly method, if authentication fails due to a communication failure with the TACACS + server aut omatic authentication fallback will occur to authenticate with the local user data base o[...]

  • Pagina 91

    4: Advanced Operations SLP: set tacpriv access admin 14<Enter> The following command sets the TACACS+ accou nt access level for account 5 to User: SLP: set tacpriv access user 5<Enter>Gr anting and removing input status viewing privileges: Granting and removing input status viewing privileges: The Set TacPriv Envmon command grants or re[...]

  • Pagina 92

    4: Advanced Operations Examples The following command s grant a TACACS+ account 5 access to outlets A1 and Webserve r_1: SLP:add outlettotacacs .a1 5<Enter> SLP:add outlettotacacs WebServer_1 5<Enter> Deleting outlet access for a TACACS+ accou nt: The Delete OutletFromTACACS comm and removes a TACACS+ account’s access to one or all ou[...]

  • Pagina 93

    4: Advanced Operations Deleting serial port access for a TACACS+ account: The Delete PortFromTACACS command re moves a TACACS+ account’s access to the serial port. You cannot remove a ccess to the serial port for an administrative level account. To delete serial port access for a T A CACS+ a ccount: At the SLP: prompt, type delete portfromtacacs [...]

  • Pagina 94

    4: Advanced Operations TACACS+ Technical Specifications Authentication START Packet includes: action = 1 (TAC_PLUS_AUTHEN_LOGIN) priv_lvl = 0 (TAC_PLUS_PRIV_LVL_MIN) authen_type = 1 (TAC_PLUS_AUTHEN_TYPE_ASCII) service = 1 (TAC_PLUS_AUTHEN_S VC_LOGIN) user = (entered username) port = (access path into the SLP) rem_addr = ‘SLP3_xxxxxx’ (xxxxxx i[...]

  • Pagina 95

    4: Advanced Operations The SLP’s Syslog support is RFC31 64-compliant and enables off-SLP viewing and storage of log messages. The SLP supports external logging to up to two Syslog servers. Syslog Command Summary Command Description Set Syslog HostIP Sets the IP address of the Syslog server Set Syslog Port Sets the Syslog server port number Show [...]

  • Pagina 96

    4: Advanced Operations Email Email Command Summary Command Description Set Email Enables or disables Email notification support Set Email SMTP Host Sets the SMTP Host IP address or hostname Set Email SMTP Port Sets the SMTP server port number Set Email From Sets the email ‘From’ address Set Email PrimaryTo Sets the primary recipient email addre[...]

  • Pagina 97

    4: Advanced Operations SLP: set email smtp port 5555<Enter> Setting the ‘From’ email address: The Set Email From command sets the ‘from’ em ail address. By default, this is set to ‘SLP3_’ plus the last three octets of the unit’s MAC address. Example: ‘SLP3_510c90@’ To set the ‘From’ email address: At the SLP: prompt, typ[...]

  • Pagina 98

    4: Advanced Operations Displaying Email configuration inform ation: The Show Email command displays Email config uration information. To display the Email configuration information: At the SLP: prompt, type show email and press Enter . Example The following command display s the Email configuration information: SLP: show email Email Configuration E[...]

  • Pagina 99

    5: Troubleshooting and Technical Support 5: T roubleshooting and T echnical Support Technical Support If you are experiencing an error that is not described in this user gu ide, or if you are unable to fix the error, you may: Check our online kn owledge base at www.lantronix.com/supp ort . Contact Technical Support in the US: Phone: 800-422-7044 (U[...]

  • Pagina 100

    A: Resetting to Factory Defaults You may reset the non-volatile RAM that stores all configurable opt ions. This clears all administrator-editable fi elds and resets all comma nd line configurable options to their default values, including all user accounts. You may reset the unit to factory defaults from the command line or the web bro wser interfa[...]

  • Pagina 101

    B: Uploading Firmware B: Uploading Firmware You may upload new versions of firm ware usi ng File Transfer Prot ocol (FTP). This allows access to new firmware releases for firmware improvements and n ew features additions. Note: To begin an FTP upload sessio n, you m ust first configure the FTP Host address, username/password, filename and file path[...]

  • Pagina 102

    C: Technical Specifications C: T echnical Specifications Models Table C-5-1. Vertical Installation Model Vo ltage Inlet Outlets SLPV1611E-02 100-120V, 50/60Hz IEC 60320/C20 16 - NEMA 5-20R SLPV1612E-02 208-230V, 50/60Hz IEC 60320/C20 16 - IEC 60320/C13 SLPV1614G-02* 208-230, 50/60Hz NEMA L6-30P, 30A locking 16 - IEC 60320/C13 Table C-5-2. Vertica l[...]

  • Pagina 103

    C: Technical Specifications SLPX08x2E-02 *SLPV16x2E - 02 *SLPY16x2E - 02 50/60 Hz SLPH0814G- 02 SLPV1614G- 02 208-230V 50/60 Hz 24 12 24 1 Current ratings are in a mperes. *Expansion model SecureLinx SLP Remote Power Man ager 102[...]

  • Pagina 104

    C: Technical Specifications Table C-5-6. Physical Specifications SLP-V16xxx-02 SLP-H08xxx-02 Size 65.0 x 1.75 x 2.25 in. 1.75 x 17.0 x 7.0 in. Physical Weight 13.2 lbs 8.2 lbs Operating 0° to 50° C (32° to 122° F) Temperature Storage -40° to 85° C (-40° to 185° F) Operating 10 to 90%, non-condensing Relative Humidit y Storage 10 to 90%, non[...]

  • Pagina 105

    C: Technical Specifications Table C-5-8. RJ45 to DB9 Serial Port A dapter Pin 1 2 3 4 5 6 7 8 9 DCE Signal Name Input/Output 1 2 Receive Data RD Output 3 Transmit Data TD Input 4 Data Terminal Ready DTR Input 5 Signal Ground 6 Data Set Ready DSR Output 7 Request to Send RTS Input 8 Clear to Send CTS Output Ethernet LED Indicators Table C-5-9. LED D[...]

  • Pagina 106

    C: Technical Specifications Temperature/Humidity Probe (Accessory ) The SecureLinx SLP Temperature and Humidity Probe monitors dat a center environmental conditions to ensu re they do not exceed recommended thresholds. The temperature and humi dity probe is a combination probe that suppo rts both temperature and humidity and plugs into either T/H1 [...]

  • Pagina 107

    D: Compliance Information (according to ISO/IEC Guide 22 and EN 45014) Manufacturer’s Name & Address : Lantronix 15353 Barranca Parkway, Irvine, CA 9261 8 USA Declares that the following product: Product Name Model: SecureLinx SLP Remote Power Manager Conforms to the following standards or other no rmative documents: USA and Canada FCC Class [...]

  • Pagina 108

    D: Compliance Information RoHS Notice: All Lantronix products in the following families are China RoHS -compliant and free of the follo wing h azardous substances and elements: • Lead (Pb) • Mercury (Hg) • Polybrominated bip henyls (PBB) • Cadmium (Cd) • Hexavalent Chromium (Cr ( VI)) • Polybrominated diphenyl ethers (PBDE) • Toxic or[...]

  • Pagina 109

    D: Compliance Information refund of buyer's purchase price fo r such affected products (without interest) repair or replacem ent of such products, provided that the buyer follows the above procedures. There are no understandings, agreem ents, repr esentations or warranties, expre ss or implied, including warranties of merchantab ility or fitne[...]