Warning: mysql_fetch_array() expects parameter 1 to be resource, boolean given in /home/newdedyk/domains/bkmanuals.com/public_html/includes/pages/manual_inc.php on line 26
GarrettCom 6K32FR manuale d’uso - BKManuals

GarrettCom 6K32FR manuale d’uso

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75

Vai alla pagina of

Un buon manuale d’uso

Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso GarrettCom 6K32FR. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica GarrettCom 6K32FR o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.

Che cosa è il manuale d’uso?

La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso GarrettCom 6K32FR descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.

Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.

Quindi cosa dovrebbe contenere il manuale perfetto?

Innanzitutto, il manuale d’uso GarrettCom 6K32FR dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo GarrettCom 6K32FR
- nome del fabbricante e anno di fabbricazione GarrettCom 6K32FR
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature GarrettCom 6K32FR
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti

Perché non leggiamo i manuali d’uso?

Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio GarrettCom 6K32FR non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti GarrettCom 6K32FR e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio GarrettCom in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche GarrettCom 6K32FR, come nel caso della versione cartacea.

Perché leggere il manuale d’uso?

Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo GarrettCom 6K32FR, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.

Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso GarrettCom 6K32FR. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.

Sommario del manuale d’uso

  • Pagina 1

    www Garre t t C om c om .. www Garre t t C om c om .. Corporate Headquarters GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com email support@garrettcom.c om Magnum 6K32F, 6K32FR, 6K32FC & 6K32FRC Industrial Managed Switch Installation and User Guide Hardware[...]

  • Pagina 2

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) i www Garre t t C om c om .. Magnum  6K32F, 6K32FR, 6K32FC & 6K32FRC Managed Switch Hardw are Installation and User Guide Part #: 84-00103Z (Rev. A) Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registere[...]

  • Pagina 3

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) ii www Garre t t C om c om .. Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom[...]

  • Pagina 4

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) iii www Garre t t C om c om .. TABLE OF CONTEN TS .......................................................................... Page 1.0 SPECIFICATIONS ................................................................................ 1 1.1 Technical Specifications ..............[...]

  • Pagina 5

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) iv www Garre t t C om c om .. 4.4 Flow-control, IEEE 802.3x standard .................................................. 46 5.0 6K32F SERIES MANAGED SWITCH PORT MODULES............. 47 5.1 Inspecting the Package and Product ................................................... [...]

  • Pagina 6

    Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) www Garr et t C om c om .. The Magnum Line INDUSTRIAL NETWORKING PRODUCTS "DESIGNED AND M ANUFACTURED IN THE US A" OVERVIEW GarrettCom, Inc. offers the premium-quality Magnum  line of INDUSTRIAL connectivity products with industry-standard functionality and built[...]

  • Pagina 7

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 1 www Garr e t t C om com .. 1.0 SPECIFICATIONS 1.1 Technical Specifications Performance Filtering / Forwarding Rate: Ethernet:14,880 pps Fast Ethernet: 148,800 pps Gigabit Ethernet: 1,488,000 pps Switching Processing Ty pe: Store and Forward with IEEE 802.3x full- duplex fl[...]

  • Pagina 8

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 2 www Garr e t t C om com .. Maximum Standard Gigabit Eth ernet Segment Lengths: 1000BASE-T (CAT5E or higher is recommended) - 100 m 1000BASE-SX, full-duplex, multi-mode(62.5  m cable) - 220m 1000BASE-SX, full-duplex, multi-mode(50  m cable) - 550m 1000BASE-LX, full-du[...]

  • Pagina 9

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 3 www Garr e t t C om com .. Fuse Required – 3 Amps 125VDC and 100VDC Input Voltage : 88 to 300VDC Fuse Required – 1 Amp Std. Terminal Block : “ -, GND, + ” Power Consumption: same as for AC models, see above Warning - All the fuse replacement must be replaced with s[...]

  • Pagina 10

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 4 www Garr e t t C om com .. 1.2 Ordering Information Magnum Managed Switch MODEL DESCRIPTION Magnum 6K32F or 6K32FR (Reverse model) 32-10/100 RJ-45 ports or 8 Gigabit ports managed switch with four modular slots whic h may be configured with a selection of 10/100/1000Mb fib[...]

  • Pagina 11

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 5 www Garr e t t C om com .. 6KP8-MTRJ SFF Fiber module, w/eight 100M b mm FX MT-RJ connectors 6KP8-MLC SFF Fiber module, w/eight 100M bps mm FX LC connectors 6KP8-SLC SFF Fiber module, w/eight 100Mbps sgl-m FX LC connectors 6KP8-45MT “4+4” module, w/four RJ-45 ports and[...]

  • Pagina 12

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 6 www Garr e t t C om com .. GBIC-TP GBIC transceiver module for use in GBPM-xOTX. One 802.3ab 1000BASE-T port with RJ-45 connector Modules with Gb, not using GBICs (all modules inc lude fr ont pane l) 6KP5-1CU4RJ “G+4” module, with one GBIC c opper (Auto-negotiating) tr[...]

  • Pagina 13

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 7 www Garr e t t C om com .. 6K32F Series PoE Modules with 48VDC Pass-Through Configuration options: All module slots of 6K32F Series switch with 48VDC pow er input may be configured w ith a PoE Module (typical configuration has slot A loaded first with PoE module) P6KP8-RJ4[...]

  • Pagina 14

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 8 www Garr e t t C om com .. 6K32F Series PoE Modules with 48VDC Power Inside NOTE: For configuring in 6K Swit c hes having AC /125VDC pow er input Configuration options: only one A, B, C or D (left to right) module slot of 6K32F Series switc h w ith 48VDC power input may be[...]

  • Pagina 15

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 9 www Garr e t t C om com .. 2.0 Introduction 2.1 Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during shipment or delivery. Inspect the conten[...]

  • Pagina 16

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 2.2 Product Description – Magnum 6K32FC / FRC (Convection cooled - No-fans) Managed Switch All of the Magnum 6K32F Series of Ethernet Switches comply with IEC61850 and IEEE1613 Utility Automation and other industry standards. The Magnum 6K32FC/FRC Managed Switc hes are spe[...]

  • Pagina 17

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 11 www Garr e t t C om com .. switching services for both “smooth” streami ng and “bursty” data traffic. For redundant LANs it offers S-ring, RS-Ring, Link-Loss-Learn, STP and RSTP. Optional Security features include SNMPv3, SSL/SSH, 802.1X , TACACS+, Port Security, [...]

  • Pagina 18

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) AC, and –48VDC power input options are de signed for Telco environments, while the 24VDC is designed for Industrial/Contro l Room applications. The 125 & 250VDC versions are for power s ub stations applications. Designed primarily for use in harsh, un-controlled temper[...]

  • Pagina 19

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) designed to meet the future demand of Ethern et requirements with cost-effective s ecure solutions. The Magnum 6K32F is also available in a Reve rse model option, where the LEDs are on the front and the available por ts along with the power supply area found on the rear side[...]

  • Pagina 20

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) when ON (half-duplex when OFF), and the blinking ACT LED indicates receiving Activity on the port. A fiber c able must be c onne c t e d into a SFF port a nd the L ink (L K) indicator for that port must be ON (indicating there is a powered-up device at the other end of the c[...]

  • Pagina 21

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 2.2.3a PoE(Power Inside), model PI 6KP8-45RJ (MDIX), 8-port 10/100Mb The New PoE RJ-45 ports act similar to regular RJ-45 ports, except they have capability of providing power on each port to power up the PD devices, per the IEEE802.3af PoE standard. Only 4 x RJ-45 (10/100) [...]

  • Pagina 22

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) modules. Please check the orde ring information Sec.1.2 for all the various P6K PoE modules option. The LEDs on 6KP8-RJ45- PoE module are slightly different compared to regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the PoE LED is ON when con[...]

  • Pagina 23

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 2.2.5 Four-Port 10 Mb mm Fiber ST Modules The 4port @10Mb ST fiber modules be have the same as the 8@100Mb ST fiber modules except for the 10Mb speed. For port numbering, ports 1, 2, 5, 6 are present, ports 3, 4, 7, 8 are not present. The de fault setup on the 10Mb fiber mod[...]

  • Pagina 24

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 18 www Garr e t t C om com .. The 1000Mb Gigabit fiber-port modul es on the Magnum 6K32F Series switches are normally set (factory default) to operate at AUTO mode for best fiber distance and performance. The 1000Mbps SC fi ber-optic module on the Gigabit -SX and s LEDs that[...]

  • Pagina 25

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 19 www Garr e t t C om com .. When the Magnum 6K32F Series Switch detects that its free buffer queue space is low, the Switch sends industry standard (full-duplex only) PAUSE packets ou the devices sending packets to cause “flow c ontrol”. This tells the sending devices [...]

  • Pagina 26

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 20 www Garr e t t C om com .. 2.3 Features and Benefits  Managed switching for high performan ce Ethernet LANs Magnum 6K32F Series Switches provide non-bl ocking (all ports can run at full speed at once) performance with standard Manage d Networks Software (MNS-6K) includ[...]

  • Pagina 27

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 21 www Garr e t t C om com .. client for IP configuring, Radius X, TACACS+ etc.  MDI-MDIX Auto-negotiating on RJ-45 ports for con venient cascading usin g straight RJ-45 cable.  Supports PoE module to provide pow e r via RJ-45 c a ble on the modular slots. 2.4 Applicat[...]

  • Pagina 28

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) The modularity of the 6K32F Series Managed Switch makes it an attractive choice for use in applications with LAN conn ections to an organization’s multiple site offices. The different offices can be easily connected together with the Fiber ports supported by the Magnum 6K3[...]

  • Pagina 29

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 23 www Garr e t t C om com .. managed to provide easy, detectable, unint errupted support through a viewable SNMP onitor. ure other security features to provide a ser e the bandwidth for high speed to upport the peak traffic and minimize congestion. DC 25s has been . data mi[...]

  • Pagina 30

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 6K32F Series in a Redundant application Example 4: In a “ (video+data)” application where a network being designed to catered the need of multicast streaming and broadcast tra ffic of higher bandwidth to provide a video conferencing and video in demand channel option to [...]

  • Pagina 31

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) Equipped with IGMP-L2 mode enhanced features allow the Magnum 6K32F Series to meet the fastest growing applica tion of video monitoring or video surveillance demand of industry and provide an economical and effective solution to meet that expectation. Figure 4: A multicast t[...]

  • Pagina 32

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 26 www Garr e t t C om com .. 3.0 Installation Before installing the equipment, it is necessary to take the following precautions: 1.) If the equipment is mounted in an enclosed or multiple rack assembly, the environmental temperature around the equipment must be less than o[...]

  • Pagina 33

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 27 www Garr e t t C om com .. 3.2 Connecting Ethernet Media The Magnum 6K32F Series Switc hes are specifically designed to support all standard Ethernet media types within a single Switch unit. This is accomplished by using a family of different port Modules which can be ind[...]

  • Pagina 34

    Magn m 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) u 28 www Garr e t t C om com .. 4. Connect the Receive (RX) port (dark colored post on the PM) to the Transmit (TX) port of the remote device. Use the non-color coded fiber strand for this. 5. The LINK LED on the front of the PM w ill illuminate when a proper connection has [...]

  • Pagina 35

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 29 www Garr e t t C om com .. shielded, either unshielded or shielded cables and wiring may be used. 2. Connect the other end of the cable to the corresponding device 3. Use the LINK LED to ensure proper connectivity by noting that t he LED will be illuminated when the unit [...]

  • Pagina 36

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 3.2.6 Gigabit SFP (Small Form-factor Pluggable ) Optical Transceivers The small form-factor pluggable (SFP) is a co mpact optical transceiver used in optical communications for both telecommunication a nd data communications applications. Due to its compact, hot pluggable ch[...]

  • Pagina 37

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) The various SFPs transceivers supported by GarrettCom 6KQs D slot are- Module Model# Gigabit Gb Modules, fixed ports--SFP (Small Form Factor) 6KP2-2GSFP 2 SFP 6KP2-1GSFP1CU 1SFP 31 www Garr e t t C om com .. 1 CU 6KP1-1SFP 1SFP 6KP1-1GCU 1 CU Gb SFP fiber optic transceivers [...]

  • Pagina 38

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 32 www Garr e t t C om com .. and the “Cable Loss” for 9/125 (Single-mode) i s 0.25 dB/km(LXSC40) and the “Cable Loss” for 9/125 (Single-mode) i s 0.2 dB/km (LXSC70) The following data has been collected from component manufacturer’s (Agilent’s and Lucent’) web[...]

  • Pagina 39

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 3.3 Table-Top or Shelf Mounting The Magnum 6K32F Series Managed Switc hes can be easily mounted on a table-top or any suitable horizontal surface. They have four rubber feet to provide stability without scratching finished surfaces. 3.3.1 Rack-mounting (for 19” RETMA racks[...]

  • Pagina 40

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) The optional 23” brackets and the ETSI (21”) brackets each come as a pair in a package, along with the necessary screws for attaching the brackets to the sides of the Magnum Switch unit. They must be ordered as separate line items. 3.3.2 Rack-mounting, Reverse version of[...]

  • Pagina 41

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 35 www Garr e t t C om com .. The 32-port units will consume over 30 watts of power typically. When connecting the Ethernet cabling, there is no need to power down the unit. Individual segments can be connected or disconnected without concern fo r AC power-related problems o[...]

  • Pagina 42

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 3.5 6K32F Series Port Module (6KPM) Installation The Magnum 6K32F Series Switches are received from the factory with the customers required 6KPM modules installed. There may be situati ons where 6KPM cards need to be added or replaced. In cases wh ere a 6KPM module needs to [...]

  • Pagina 43

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) Step 2. Remove Chassis Cover The Magnum 6K32F chassis are combined with top, bottom and module panel parts and assembled together with the help of 34 Philips-head screws. First Remove the side panel (2 screws located on the right side of chassis). Second, remove the module p[...]

  • Pagina 44

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) Looking down into the Magnum 6K32F Series un it, notice that there are individual PM installation spaces and female latch (white) c onnectors provided on the far right side of the main board along with four stand-off’s for 6KPM card position. (See Figure 3.5.1c). Figure 3.[...]

  • Pagina 45

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) Step 3. The figure here illustrates the basic lay out of an individual PM card. 6KPM card fits into the space provided on the main board over the grand-daughter Bd. a nd the ( as shown in below fig. with arrow mark). male latched cream color connectors ig 3.5.2b: Daughter Bo[...]

  • Pagina 46

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) NOTE: . When leaving 6KPM slots empty, always use a face plate (Magnum 6KM- BLNK) to cover the slot opening in the fr ont panel. This will ma intain proper cooling air flow, safety, and operation as requir ed by FCC, CE, and other regulations. Step 6. Now screw down the daug[...]

  • Pagina 47

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) Step 2. Remove retaining screws placed on top for the 6KPM On the top of the daughter module there are seven retaining screws for each 6KPM card. These screws are used to secure a 6KPM card in pos ition (see Figure 3.5.3a). Remove the three standoffs holding the Granddaughte[...]

  • Pagina 48

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 3.6 Connecting the Console Terminal to Magnum 6K32F Series Management) ( Use a DB-9 “null modem” cable to connect the Magnum 6K32F Series Console Port (the RS-232 port on the 6K32F Switch) to the your PC, so that your PC becomes the 6K32F ’s Console Terminal. Note: The[...]

  • Pagina 49

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 43 www Garr e t t C om com .. connect directly to the switch using a straight through cable. Note : For using Console port to configure the managed switch, a serial (Null-modem) female to female cable is required to communicate properly. The Null-Modem (DB-9) er fro m the fa[...]

  • Pagina 50

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 44 www Garr e t t C om com .. 4.0 OPERATION This chapter describes the functions and operation of the Magnum 6K32F Series Switch. 4.1 Switching Functionality A Magnum 6K32F Series provides switche d connectivity at Ethernet wire- speed among all of its ports . The Magnum 6K3[...]

  • Pagina 51

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 45 www Garr e t t C om com .. 4.2 Status LEDs For all Magnum 6K32F Series models : PWR: Power LED, ON when external power is applied to the unit. LK: Steady ON, Link status for 10 Mbps and 100Mbps operation. ACT: ON with port activity for 10 Mbps and 100Mbps operation. F/H: [...]

  • Pagina 52

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) When Magnum 6K32F Series RJ-45 coppe r ports are set for auto-negotiation and are connected to another auto-negotiating device, there are 4 different speed and F/H modes possible depending on what the other device supports. These are: (1) 100Mb full- duplex, (2) 100Mb half-d[...]

  • Pagina 53

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 47 www Garr e t t C om com .. blocking) on Full-Duplex ports, which provide s for a “PAUSE” packet to be transmitted to the sender when the packet buffer is nearly filled and there is danger of lost packets. The transmitting device is commanded to stop transmitting into [...]

  • Pagina 54

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) modular slot. Since the Magnum 6K32F Series Switches have dual-speed capability for copper ports, the 6 or 8-por t interfaces are designed to support all standard Ethernet media types at 10 or 100Mps speed. E ach 6K32F PM can provide two, four, six or eight ports for connect[...]

  • Pagina 55

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) connector functions as a fiber optic tr ansceiver to support 10BASE-FX network segments. When installed in a Magnum 6K32F Series Managed Switch, the copper port supports the standard distance 100m on each port and the fiber port supports fiber optic cable distances up to the[...]

  • Pagina 56

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) provide a convenient way for the half duplex hub to connect to the switch through 10Mb fiber ports. Whereas the 100Mb ST module a llows it to connect the 100Mb demand of the Switch devices. It supports distances according to the 10Base-FL standard i.e, 2Km distance for mu lt[...]

  • Pagina 57

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 51 www Garr e t t C om com .. functions in one module of the 6K32F Se ries Switch supporting four Copper and two single-m s -mode and cable lengths can be as much as a The e 6KP6-RJMSC, the label Sgl. M.” is at the top of the faceplate of the 6KP6-RJS SC. 5.2.4 per port an[...]

  • Pagina 58

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) indicating proper connectivity with the re mote device when lit, and a FDX/HDX L indicating full-duplex mode when lit (or half-duplex when off). The 10/100 LED indicates the speed for the co ED pper port, wh ich is 10Mbps when the LED is ON and 10 Mb when the LED is OFF. .2.[...]

  • Pagina 59

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) the same as the ST and SC-types. It has the same LEDs per port indicating port activity ACT), Link (LK), and FDX or HDX operation ( 5.2.6 6KP8-45MT, 4@ 10/100Mbps RJ-45 and 4@100Mb multi-mode FX , MTRJ Small-Form-Factor The Magnum 6KP (Small Form Factor) MTRJ type ports. The[...]

  • Pagina 60

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) the remote device when lit, and a FDX/HDX LED indicating full-duplex mode when lit (or half-duplex when off). 5.2.8 -LC small-form 6KP8-45LC, Combo 4@ 100Mbps multi-mode factor and 4@ 10/100 Mbps RJ-45 Connector The Magnum 6KP8-45LC Module is a combo module with a combinatio[...]

  • Pagina 61

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) Each port has an Activity (ACT) LED indicating packets being received, a Link (LK) LED that indicates proper connec tivity with the remote device when lit, a FDX/HDX LED to indicate full-duplex mode wh en lit (or half-duplex when off), and a and “10/100” LED indicating 1[...]

  • Pagina 62

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 56 www Garr e t t C om com .. informati the roperly to an 803.af compliant PD device on that port. When no PoE ED on Sec.1.2 for all the various P6K PoE modules option. The LEDs on 6KP8-RJ45- PoE modules ar e slightly different compared to regular (non-PoE) RJ-45 modules as [...]

  • Pagina 63

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) traffic is not affected by PoE. LINK and ACTIVITY LEDS are combined hat is marked as LINK/ACT, as shown in the diagram PoE ED on the PoE modules into one LED . t L s Summary For P  oE devices, each RJ-45 PoE port supports only 802.3af complaint devices. The PoE LED is ON [...]

  • Pagina 64

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 5.2.11a 6KP8-45-2LC, 6@ 10/100Mbps RJ-45 and 2@100Mb single-mode FX , LC Small-Form-Factor The Magnum 6KP8- 45SLC eight port Module is a combo module with copper and fiber (Small Form Factor) LC type fiber ports. The small size of LC connectors give an advantage of placing m[...]

  • Pagina 65

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 5.2.12a GBPM-2OTX (Two Gigabit option) The Magnum 6K32-Series offered a wide selection of Gigabit speed with multiple choice of copper or Fiber or mix for the modular slot via GBPM-2OTX (2 x Giga module). While up to two Gigabit modules (max.) can be configured in the modula[...]

  • Pagina 66

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) The two Giga port has been offered as GBPM-2OTX (fiber or RJ-45), whereas the single Gigabit module comes in flavor of G+4(10/100 RJ-45 ports) or G+2 (100Mb fiber ports) as shown below in the above figure. Each port has an Activity (ACT) LED indicating packets being received[...]

  • Pagina 67

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 61 www Garr e t t C om com .. 6.1 Befo re Ca lling for Assistance 1. If difficulty is encountered when insta lling or operating the unit, refer back to the Installation Section of the applicable chapter of this manual. Also check to make sure that the various compone nts of [...]

  • Pagina 68

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 62 www Garr e t t C om com .. 2. An accurate list of GarrettCom product model(s) involved, with serial number(s). Include the date(s) that you purchased the products from your supplier. 3. It is useful to include other networ k equipment models and related hardware, includin[...]

  • Pagina 69

    Magnum 6K32F/FR/FC/FRC Managed Switch In tallat s ion and User Guide (05/08) 63 www Garr e t t C om com .. 6.4 Shipping and Packaging Information Should you need to ship the unit b ack to GarrettCom, please follow these instructions: 1. Package the unit carefully. It is r ecommended that you use the original container if available. Units should be [...]

  • Pagina 70

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) APPENDIX B : Internal DC Power Supply Options B1.0 SPECIFICATIONS FOR MAG NUM 6K32F SERIES SWITCHES, DC POWER Power Supply (Inte rnal -48VDC Option) DC Power Connector: 3 terminals: “ - “, “GND”, “+” Input Voltage: 36 - 70 VDC Power Consumption: Same as for AC mo[...]

  • Pagina 71

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) B3.0 APPLICATIONS FOR DC POWERED SWITCHES Magnum 6K32F Series Fiber Switches ar e easily installed in a variety of applications where -48VDC, 24VDC and 125VDC power is used as the primary power source. The- 48VDC, 24VDC and 125VDC power configuration provides an Ethernet net[...]

  • Pagina 72

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 66 www Garr e t t C om com .. Note: The GND should be hooked up first. The 6K32F unit has a floating ground, so the user may elect to Grou nd either + or - ter minal to suit the customer ’s use. Before connecting hot lin es to the Terminal Bl ock of –48VDC, 24VDC or 125V[...]

  • Pagina 73

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) APPENDIX C: Internal DC Dual-Source Power Option C1.0 SPECIFICATIONS - FOR MAG NUM 6K32F SERIES FIBER SWITCH Power Supply (Internal, -48VDC Dual -Source, model # Dual-Src-48V) DC Power Connector: First Source: “A+”, “A -“ , 2nd Source “B - “, “B+” GND: Termin[...]

  • Pagina 74

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) C3.0 DUAL-SOURCE OPTION, THEORY OF OPERATION The Dual-Source DC power option is designed using diodes inside of the chassis on each DC power input line. A diode is placed in each of the four input lines (behind the four external power connection te rminals) so that power fro[...]

  • Pagina 75

    Magnum 6K32F/FR/FC/FRC Managed Switch In stallation and User Guide (05/08) 69 www Garr e t t C om com .. Note: The GND should be hooked up first. The 6K32F Series units have a floating ground, so th e user may elect to Ground eith er + or - terminal to suit th e customer’s use. Before connecting hot lin es to the Terminal Bl ock of –48VDC, 24VD[...]