Warning: mysql_fetch_array() expects parameter 1 to be resource, boolean given in /home/newdedyk/domains/bkmanuals.com/public_html/includes/pages/manual_inc.php on line 26
Dell 53-1002116-01 manuale d’uso - BKManuals

Dell 53-1002116-01 manuale d’uso

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168

Vai alla pagina of

Un buon manuale d’uso

Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Dell 53-1002116-01. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Dell 53-1002116-01 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.

Che cosa è il manuale d’uso?

La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Dell 53-1002116-01 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.

Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.

Quindi cosa dovrebbe contenere il manuale perfetto?

Innanzitutto, il manuale d’uso Dell 53-1002116-01 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Dell 53-1002116-01
- nome del fabbricante e anno di fabbricazione Dell 53-1002116-01
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Dell 53-1002116-01
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti

Perché non leggiamo i manuali d’uso?

Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Dell 53-1002116-01 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Dell 53-1002116-01 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Dell in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Dell 53-1002116-01, come nel caso della versione cartacea.

Perché leggere il manuale d’uso?

Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Dell 53-1002116-01, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.

Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Dell 53-1002116-01. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.

Sommario del manuale d’uso

  • Pagina 1

    53-1002 11 6-0 1 07 D e c e m b e r 2 010 Dell Con v erged Enhanced Etherne t Administrat or’s Guide[...]

  • Pagina 2

    Information in this document is subject to change without notice. © 20 10 Dell Inc. All rights reser v ed. Repr o duction of these ma terials in any manner whatsoever withou t the written permission of Dell Inc. is strictly forbidden. T rademarks used in this text: Dell , the DELL logo, Inspiron , Dell Precision , Dimension , Opt iPlex , Latitude,[...]

  • Pagina 3

    Dell Converged Enhanced Ethernet Administrator ’s Guide iii 53-1002116-01 Contents About This Document In this chapt er . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv Suppor ted har dware and software . . . . . . . .[...]

  • Pagina 4

    iv Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Chapter 2 Using the CEE CLI In this chapt er . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Management T ools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 CEE Command Line Inte r face . . . . . . .[...]

  • Pagina 5

    Dell Converged Enhanced Ethernet Administrator ’s Guide v 53-1002116-01 VLAN configuration and management . . . . . . . . . . . . . . . . . . . . . . . . 34 Enabling and disabl ing an int er face por t . . . . . . . . . . . . . . . . . . 34 Configuring the MTU on an int er face por t . . . . . . . . . . . . . . . . . 34 Creating a VLAN int er fac[...]

  • Pagina 6

    vi Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 STP , RS TP , and MS TP configuration and management . . . . . . . . . . 5 1 Enabling STP , RS TP , or MS TP . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1 Disabling STP , RS TP , or MSTP . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1 Shutting down S TP[...]

  • Pagina 7

    Dell Converged Enhanced Ethernet Administrator ’s Guide vii 53-1002116-01 LA CP configuration and management . . . . . . . . . . . . . . . . . . . . . . . . 69 Enabling LA CP on a CEE interface . . . . . . . . . . . . . . . . . . . . . . . 69 Configuring the LA CP system priority . . . . . . . . . . . . . . . . . . . . . 70 Configuring the LACP t[...]

  • Pagina 8

    viii Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Chapter 10 Configuring QoS using the CEE CLI In this chapt er . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 QoS ov er view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 3 Re writing . . [...]

  • Pagina 9

    Dell Converged Enhanced Ethernet Administrator ’s Guide ix 53-1002116-01 Chapter 13 Configuring Port Mirroring using the CEE CLI In this chapt er . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 Port Mirroring pr otocol ov erview . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 Port Mirroring limita[...]

  • Pagina 10

    x Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Managing and displaying the F CoE lo gin configuration . . . . . . . . . 133 Enabling or disabling FC oE login configuration management . . . . . . . . . . . . . . . . . . . . . . . . . . . .133 Displaying or abortin g the current configuration transaction . . . . . . . . . .[...]

  • Pagina 11

    Dell Converged Enhanced Ethernet Administrator ’s Guide xi 53-1002116-01 Figures Figure 1 Multiple switch fabric configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Figure 2 CEE CLI command mode hie rarchy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Figure 3 Ingress VLAN filte ring [...]

  • Pagina 12

    xii Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01[...]

  • Pagina 13

    Dell Converged Enhanced Ethernet Administrator ’s Guide xiii 53-1002116-01 Tables Ta b l e 1 FCoE terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Ta b l e 2 CEE RBAC permissions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Ta b l [...]

  • Pagina 14

    xiv Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01[...]

  • Pagina 15

    Dell Converged Enhanced Ethernet Administrator ’s Guide xv 53-1002116-01 About This Document In this chapter • How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv • Suppor ted har dware and software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi • Document conv entions [...]

  • Pagina 16

    xvi Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 • Chapter 13, “Configuring Port Mirroring using the CEE CLI,” describes how t o configure Por t Mirror ing. • Chapter 1 4, “Configuring RMON using the CEE CLI,” describes how t o configure remote monitoring (RMON). • Chapter 15 , “Configuring IGMP ,” descr[...]

  • Pagina 17

    Dell Converged Enhanced Ethernet Administrator ’s Guide xvii 53-1002116-01 For readability , comma nd names in the narrative por tions of this guide are presented in mixed letter case: for ex ample, switchShow . In actual examples, command lett ercase is of ten all lower case. Other wise, this manual specif ically notes those cases in which a com[...]

  • Pagina 18

    xviii Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Notice to the reader This document may contain ref erences to the tr ademarks of the f ollowing corporations. These trademarks are the properties of their respective companies and corporations. These ref erences are made f or informational purposes only . Getting technica[...]

  • Pagina 19

    Dell Converged Enhanced Ethernet Administrator ’s Guide 1 53-1002116-01 Chapter 1 Introducing FCoE In this chapter • FCoE terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 • FCoE ov er view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [...]

  • Pagina 20

    2 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 FCoE overview 1 The motiv ation behind usi ng CEE networ ks as a tr anspor t mechanism f or FC arises from the desire to simplify host pr otocol stacks and consolidat e network inter faces in data cent er environme nts. FC standards allow f or building highly reliable, high -[...]

  • Pagina 21

    Dell Converged Enhanced Ethernet Administrator ’s Guide 3 53-1002116-01 Layer 2 Ethernet overview 1 Layer 2 Ethernet overview The Dell FCoE hardw are contain CE E por ts that su ppor t FCoE forwarding. T he CEE por ts are also backwar ds compatible and suppor t clas sic Lay er 2 Ethernet networks (see Figu re 1 ). In Layer 2 Ethernet operation, a[...]

  • Pagina 22

    4 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Layer 2 Ethernet overview 1 The Dell FCoE hardware handles Ethernet frames as follo ws: • When the destination MA C address is not in the lookup table, the frame is flooded on all ports ex cept the ingress por t . • When the destination MA C address is present in th e loo[...]

  • Pagina 23

    Dell Converged Enhanced Ethernet Administrator ’s Guide 5 53-1002116-01 Layer 2 Ethernet overview 1 Loop-free network environment The Dell FCoE hardw are uses the follo wing prot ocols to maintain a loop-free netw ork envir onment: • 8 0 2 .1D S p a n n i n g Tr e e P r o t o c o l ( ST P ) — S T P i s r e q u i r e d t o c r e a te a l o o p[...]

  • Pagina 24

    6 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Layer 2 Ethernet overview 1 Congestion control and queuing The Dell FCoE har dware supports several co ngestion control and q ueuing strategies. As an output queue appr oaches congestion, Random Early Detect ion (RED) is used to selectively and proactively dro p frames to mai[...]

  • Pagina 25

    Dell Converged Enhanced Ethernet Administrator ’s Guide 7 53-1002116-01 Layer 2 Ethernet overview 1 - Multicast output queuing— A typical multicast output queuing example is where sev eral por ts carr y multicas t inbound traf fic. Each por t has a dif ferent priority setting. T raf fic from all port s is switched to the same outbound port. If [...]

  • Pagina 26

    8 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 FCoE Initialization Protocol 1 Trunking NOTE The term “trunking” in an Ethernet netwo rk refers to the use of mult iple network links (por ts) in parallel to incre ase the link speed beyond the limits of any one single link or port, and to increase the redundancy f or hig[...]

  • Pagina 27

    Dell Converged Enhanced Ethernet Administrator ’s Guide 9 53-1002116-01 FCoE Initialization Protocol 1 The Dell FCoE har dware FIP discov er y phase operates as f ollows: • The Dell FCoE ha rdware uses the FCoE Initial ization Protocol (FIP). Enodes discover FCFs and initialize the FCoE connection through the FIP . • Solicited adver tisements[...]

  • Pagina 28

    10 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 FCoE Initialization Protocol 1 FIP logout FIP logout operat es as follo ws: • ENodes can log out fr om the Dell FCoE hardw are using FIP . The Dell FCoE har dware in the fabric upd ates the MA C address, WWN, and PI D mappings upon logout. T he Dell FCoE hardware also hand[...]

  • Pagina 29

    Dell Converged Enhanced Ethernet Administrator ’s Guide 11 53-1002116-01 FCoE Initialization Protocol 1 Logincfg The Dell FCoE hardware logincfg mechanism operates as f ollows: • The logincfg is the mec hanism for controlling ENode logins per Dell FCoE hardware. Each unit of Dell FCoE hardware maintains its own logincfg. • Login configuration[...]

  • Pagina 30

    12 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 FCoE qu euing 1 • ENodes can access all FC devices with no zo ning—ENodes can access all FC devices in the fabric when cfgdisable is issued and Default Zone is se t to All Access Mode. • Field replacement—When a Dell FC oE hardw are is replaced in the field, you can [...]

  • Pagina 31

    Dell Converged Enhanced Ethernet Administrator ’s Guide 13 53-1002116-01 Chapter 2 Using the CEE CLI In this chapter • Management T ools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 • CEE Command Line Inte r face . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 • In[...]

  • Pagina 32

    14 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 CEE Command Line Interface 2 NOTE The CEE configuratio n is not affected b y configUpload and configDo wnload commands entered in the Fabric OS shell. Saving your configuration changes Any configuration changes made to the switch are written into the ru nning-config file. Th[...]

  • Pagina 33

    Dell Converged Enhanced Ethernet Administrator ’s Guide 15 53-1002116-01 CEE Command Li ne Interface 2 Accessing the CEE CLI throug h the console or Telnet NOTE While this example uses the UserID role t o log in to the switch, any ro le li sted in the “CEE CLI RBA C permissions” section can be used. The proc edure to access the CEE CLI is the[...]

  • Pagina 34

    16 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 CEE Command Line Interface 2 NOTE At syst em star tup, if you try to enter Privileged EXEC mode bef ore the system has fully boot ed, the follo wing message is displayed: %Info: Please wait. System configuration is being loaded. After the system has fully boot ed, a RASLOG m[...]

  • Pagina 35

    Dell Converged Enhanced Ethernet Administrator ’s Guide 17 53-1002116-01 CEE Command Li ne Interface 2 NOTE Pressing Ctrl+Z or ent ering the end command in an y mode returns you t o Privileged EXEC mode. Entering exit in any mode returns y ou to the previous mo de. CEE CLI keyboard shortcuts Ta b l e 4 lists CEE CLI keyboard shor tcuts. NOTE In E[...]

  • Pagina 36

    18 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 CEE Command Line Interface 2 Using the do command as a shortcut Y ou can use the do command to sa ve time when you are working in an y conf iguration mode and you w ant to run a command in the EXEC or Privileged EXEC mode. For e xample, if you are configur ing an LL DP and y[...]

  • Pagina 37

    Dell Converged Enhanced Ethernet Administrator ’s Guide 19 53-1002116-01 CEE Command Li ne Interface 2 The CEE CLI accepts abbreviations for commands. This example is the abbre viation for the show qos interface all comman d. switch# sh q i a If the switch does not rec ognize a command af ter Ent er is pressed, an error message displays. switch# [...]

  • Pagina 38

    20 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Internal and external 10 Gbps Ethernet interfaces syntax 2 Internal and external 10 Gbps Ethernet interfaces syntax Fabric OS v6.3. 1_cee uses two separate int er face operands to ref er to internal and e xternal 1 0Gbps Ethernet por ts; intengig abitethernet and extengigabi[...]

  • Pagina 39

    Dell Converged Enhanced Ethernet Administrator ’s Guide 21 53-1002116-01 Chapter 3 Initial FCoE and CEE Configuration In this chapter • Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1 • Configuring the FCoE int er faces . . . . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Pagina 40

    22 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Configuring the FCoE interfaces 3 Only a single FCoE map is allowed, which is crea ted automatically with the name “def ault.” Y ou are no t be a b le to d el e te or r e n am e t hi s m ap . By default, if there are no other conflicting configurations, the FCoE VLAN ass[...]

  • Pagina 41

    Dell Converged Enhanced Ethernet Administrator ’s Guide 23 53-1002116-01 Configuring the CEE interfaces 3 Assigning FCoE map on to an interface The FCoE map cannot be edited, if it is associated t o any int er faces. The FCoE map can be applied, irrespective of whethe r the interface is in ‘switchpor t’ or not. But the FCoE map cannot be appl[...]

  • Pagina 42

    24 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Configuring DCBX 3 T o configure the CEE interfaces, per form the f ollowing steps in global configuration mode. 1. Assign VLANs to the uplink Ethernet port. NOTE Y ou must repeat this step for all uplink int er faces. For details, see “Configuring an int er face por t as [...]

  • Pagina 43

    Dell Converged Enhanced Ethernet Administrator ’s Guide 25 53-1002116-01 Configuring S panning Tree Protocol 3 2. Activat e the protocol. switch(conf-lldp)# no disable 3. A ctivat e the TL V format s using the advertise command in Prot ocol LLDP Conf iguration Mode. switch(conf-lldp)# advertise dcbx-fcoe-app-tlv switch(conf-lldp)# advertise dcbx-[...]

  • Pagina 44

    26 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Configuring protect mo de 3 T o configure V LAN membership, per form the f ollowing steps in global configuration m ode. 1. Creat e the VLAN interfaces on the Dell FCoE har dware using the CEE CLI. For details, see “Creating a VLAN interface” on page 35. The f ollowing e[...]

  • Pagina 45

    Dell Converged Enhanced Ethernet Administrator ’s Guide 27 53-1002116-01 Chapter 4 Configuring IP static routes In this chapter • IP static r outes ov er view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 7 • Configuring IP static rout es . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Pagina 46

    28 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Configuring IP static routes 4 Configuring IP static routes In directly attached static r outes, o nly the output inter face is spec ified. The destination is assumed to be direct ly attached to this interface, so the packet destination is used as the next-hop ad dress. Dire[...]

  • Pagina 47

    Dell Converged Enhanced Ethernet Administrator ’s Guide 29 53-1002116-01 Configuring IP static routes 4 Recursive IP static routes In a recursive IP static r oute, only the ne xt hop is specified. The output interface is derived fr om the next hop. A recursive IP static rout e is valid (that is, it is a candidate for inser tion in the routing tab[...]

  • Pagina 48

    30 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Configuring IP static routes 4 2. Displa y the detailed inf ormation about all the IP st atic rout es. switch> show ip route all Codes: C - connected, S - static, R - RIP, M - mobile, B - BGP D - EIGRP, EX - EIGRP external, O - OSPF, IA - OSPF inter area N1 - OSPF NSSA ex[...]

  • Pagina 49

    Dell Converged Enhanced Ethernet Administrator ’s Guide 31 53-1002116-01 Chapter 5 Configuring VLANs Using the CEE CLI In this chapter • VLAN ov er view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1 • Ingress VLAN filtering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [...]

  • Pagina 50

    32 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Ingress VLAN filtering 5 • Admit VLAN tagged and untag ged frames—All tagged and untagged frames wo uld be processed as f ollows: - All untagged frames are clas sified into nativ e VLANs. - All frames egressing are untagged f o r the nativ e VLANs. - Any tagged frames co[...]

  • Pagina 51

    Dell Converged Enhanced Ethernet Administrator ’s Guide 33 53-1002116-01 VLAN configuration guidelines a nd restrictions 5 Additionally , there are impor tant facts you should kno w about the VLAN FDB: • The VLAN FDB co ntains inf ormation that helps det ermine the forwarding of an arriving frame based on MA C address and VLAN ID data. The FD B[...]

  • Pagina 52

    34 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 VLAN configuration and management 5 VLAN configuration and management NOTE T o see the minimum configuration requ ired to en able FCoE o n Dell FCoE hardware, ref er to Chapt er 3, “Initial FCoE and CEE Configuration” . NOTE Y ou need to ent er either the copy running-co[...]

  • Pagina 53

    Dell Converged Enhanced Ethernet Administrator ’s Guide 35 53-1002116-01 VLAN configuration and management 5 Creating a VLAN interface On Dell FCoE hardw are, VLANs are treat ed as in terfaces from a configuration point of vie w. By default all the CEE ports are assigned to VLAN 1 (VLAN ID equals 1). The VLAN ID value can be 1 through 358 3. VLAN[...]

  • Pagina 54

    36 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 VLAN configuration and management 5 Configuring a VLAN interfac e to forward FCoE traffic An FCoE Forwarder (FCF) is an FCoE device that supports FCoE VF _por ts. It is the equivalent of an FC switch. A VLAN can be made FCF-capabl e. On ly FCF-capable VLANs can carr y FCoE t[...]

  • Pagina 55

    Dell Converged Enhanced Ethernet Administrator ’s Guide 37 53-1002116-01 VLAN configuration and management 5 Configuring an interface port as a trunk interface Each CEE inter face por t suppor ts admission polici es based on whether the frames are untagged or tagged. T runk mode admits only VLAN-tagged frames. T o configure the interface as a tru[...]

  • Pagina 56

    38 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Configuring protocol-based VLAN classifi er rules 5 T o configure the interface as conv erged inter face, per fo rm the following st eps from Privileged EXEC mode. 1. Ente r t h e configure term inal command to access globa l configuration mode. 2. Ent er t he inter face com[...]

  • Pagina 57

    Dell Converged Enhanced Ethernet Administrator ’s Guide 39 53-1002116-01 Configuring protocol-based VLAN classifier rules 5 • FCoE Initializat ion Protocol (FIP) • IP version 6 (IPv6) NOTE For complet e information on all available VLAN classifier rule optio ns, see the Con verged Enhanced Ethernet Command R eference . Configuring a VLAN clas[...]

  • Pagina 58

    40 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Configuring the MAC address table 5 Activating a VLAN classifier group with an interface port T o associate a VLAN classif ier group with an inter face por t, per form the following st eps from Privileged EXEC mode. 1. Ente r t h e configure term inal command to access globa[...]

  • Pagina 59

    Dell Converged Enhanced Ethernet Administrator ’s Guide 41 53-1002116-01 Configuring the MAC address table 5 Specifying or disabling the aging time for MAC addresses Y ou can set the length of tim e that a dynamic entry remains in the MA C address table af ter the entr y is used or updated. Static address entries are nev er aged or remov ed from [...]

  • Pagina 60

    42 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Configuring the MAC address table 5[...]

  • Pagina 61

    Dell Converged Enhanced Ethernet Administrator ’s Guide 43 53-1002116-01 Chapter 6 Configuring STP, RSTP, and MSTP using the CEE CLI In this chapter • STP o verview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 • RSTP o verview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Pagina 62

    44 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 STP overview 6 • Disabled—The interface is not par ticipating in spanning tree because of a shutdown por t, no link on the por t, or no spanning tree inst ance running on th e por t. A por t par ticipating in span ning tree mov es through these states: • F rom initiali[...]

  • Pagina 63

    Dell Converged Enhanced Ethernet Administrator ’s Guide 45 53-1002116-01 RSTP overview 6 6. Enable the guard r oot feature with the spanning-tree guard r oot command. The guar d root fe ature provides a w ay t o enforce the root bridge placeme nt in the network. For de tailed information, ref er to “Enabling the gu ard root” on page 59. No te[...]

  • Pagina 64

    46 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 RSTP overview 6 With RSTP , the por t roles f or the new interface st at es are also dif ferent. RS TP dif ferentiat es explicitly between the state of the por t and the role it plays in the topology . RSTP uses the root por t and designat ed por t roles defined b y STP , bu[...]

  • Pagina 65

    Dell Converged Enhanced Ethernet Administrator ’s Guide 47 53-1002116-01 MSTP overview 6 1 0. Configure the bridge hello time value. F or details, see “Specifying the bridge hello time (S TP and RSTP)” on page 54. switch(conf-stp)# hello-time 5 11 . Flush the MAC ad dresses from the VLAN FDB. F or details, see “Flushing MA C addresses (R ST[...]

  • Pagina 66

    48 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 MSTP overview 6 spanning tree instances. With MSTP y ou can have multiple f or warding paths f or data traf fic. A failure in one instance does no t af fect other instan c es . W ith MSTP , yo u a re ab le to m or e ef fect ive ly utilize the ph ysical resources present in t[...]

  • Pagina 67

    Dell Converged Enhanced Ethernet Administrator ’s Guide 49 53-1002116-01 STP, RSTP, and MSTP configurat ion guidelines and restrictio ns 6 5. Map a VLAN t o an MSTP instance using the in stance command. For more details see “Mapping a VLAN to an MS TP in stance” on page 55. switch(conf-mstp)# instance 1 vlan 2, 3 switch(conf-mstp)# instance 2[...]

  • Pagina 68

    50 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Default STP, RSTP, and MSTP configuration 6 Default STP, RSTP, and MSTP configuration Ta b l e 9 lists the default S TP , RS TP , and MS TP configuration. Ta b l e 10 lists the switch defaults that apply onl y to MSTP configurations. Ta b l e 1 1 lists the switch def aults f[...]

  • Pagina 69

    Dell Converged Enhanced Ethernet Administrator ’s Guide 51 53-1002116-01 STP, RSTP, and MSTP configuration and management 6 STP, RSTP, and MSTP conf iguration and management NOTE T o see the minimum configuration req uired to enab le FCoE on the Dell M8428-k switch, ref er to Chapter 3, “Initial FCoE and CEE Configuration ” . NOTE Y ou need t[...]

  • Pagina 70

    52 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 STP, RSTP, and MS TP conf iguration and man agement 6 Specifying the bridge priority In any mode (STP , RSTP , o r MSTP), use this comm and to specify the priorit y of the switch . Af ter you decide on the r oot switch, set the appropriat e values to designat e the s witch a[...]

  • Pagina 71

    Dell Converged Enhanced Ethernet Administrator ’s Guide 53 53-1002116-01 STP, RSTP, and MSTP configuration and management 6 Specifying the bridge maximum aging time In any mode (STP , RSTP , or MSTP), use this comm and t o control the maximum length of time that passes before an inter face sa ves its Bridge Protoc ol Data Unit (BPDU) conf igurati[...]

  • Pagina 72

    54 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 STP, RSTP, and MS TP conf iguration and man agement 6 Specifying the port-channel path cost In any mode (STP , RSTP , or MSTP), use this comm and to specify the por t-ch annel path cost. The default por t cost is standard . The path cost options are: • custom —Spec ifies[...]

  • Pagina 73

    Dell Converged Enhanced Ethernet Administrator ’s Guide 55 53-1002116-01 STP, RSTP, and MSTP configuration and management 6 Enabling Cisco interoperability (MSTP) In MSTP mod e, use this command to enable or di sable the ability of the Dell FCoE hardware to inter operate with certain legacy Cisco switches. If C i sco interoperability is required [...]

  • Pagina 74

    56 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 STP, RSTP, and MS TP conf iguration and man agement 6 Specifying the maximum number of hops for a BPDU (MSTP) In MS TP mode, use this comm and to configure the maximum number of hops f or a BPDU in an MSTP reg ion. Specifying the maximum hops f o r a BPDU prev ents the messa[...]

  • Pagina 75

    Dell Converged Enhanced Ethernet Administrator ’s Guide 57 53-1002116-01 STP, RSTP, and MSTP configuration and management 6 Flushing MAC addresses (RSTP and MSTP) For RS TP and MSTP , use this command t o flush the MAC addre sses from the VLAN filtering database (FDB). The VLAN FDB determines the f o rwarding of an incoming frame. The VLAN FDB co[...]

  • Pagina 76

    58 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Configuring STP, RSTP, or MS TP on CEE interface ports 6 T o restar t the protocol migration pr ocess, per f orm th e follo wing tasks from Privileged EXEC mode. 1. Ent er the appropriat e form of the clear command based on what you wan t to cle ar : • T o clear all spanni[...]

  • Pagina 77

    Dell Converged Enhanced Ethernet Administrator ’s Guide 59 53-1002116-01 Configuring STP, RSTP, or MS TP on CEE interface ports 6 T o configure the path cost f or spanning tree ca lculations on the CEE interface, per form the follo wing steps from Privileged EXEC mode. 1. Ente r t h e configure term inal command to access globa l configuration mo[...]

  • Pagina 78

    60 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Configuring STP, RSTP, or MS TP on CEE interface ports 6 Guard r oot pro tects the roo t bridge from mali cious attacks and unint entional misconf igurations where a bridge de vice that is not intended t o be the root bridge beco mes the root bridge. This causes sev ere bott[...]

  • Pagina 79

    Dell Converged Enhanced Ethernet Administrator ’s Guide 61 53-1002116-01 Configuring STP, RSTP, or MS TP on CEE interface ports 6 4. Ent er t he spanning-tree command to specify the restrictions f or an MSTP instance on a CEE interface. switch(conf-if-te-0/1)# spanning-tree instance 5 cost 3550 restricted-tcn Specifying a link type F rom the CEE [...]

  • Pagina 80

    62 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Configuring STP, RSTP, or MS TP on CEE interface ports 6 T o specify the port priority on the CEE interface, pe r fo rm the follo wing steps from Privileged EXEC mode. 1. Ente r t h e configure term inal command to access globa l configuration mode. 2. Ent er t he inter face[...]

  • Pagina 81

    Dell Converged Enhanced Ethernet Administrator ’s Guide 63 53-1002116-01 Configuring STP, RSTP, or MS TP on CEE interface ports 6 T o enable spanning tree on the CEE int er face, perform the f ollowing st eps from Privileged EXEC mode. 1. Ente r t h e configure term inal command to access globa l configuration mode. 2. Ent er t he inter face comm[...]

  • Pagina 82

    64 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Configuring STP, RSTP, or MS TP on CEE interface ports 6[...]

  • Pagina 83

    Dell Converged Enhanced Ethernet Administrator ’s Guide 65 53-1002116-01 Chapter 7 Configuring Link Aggregation using the CEE CLI In this chapter • Link aggregation o ver view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 • LACP configuration guidelines and restrictions . . . . . . . . . . . . . . . . . . . [...]

  • Pagina 84

    66 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Link aggregation overview 7 On each por t, link aggregation control: • Maintains configuration information to control port aggregation. • Exchanges configuration information with other devices to f orm LAGs. • Attaches ports to and detaches ports from the aggregat or w[...]

  • Pagina 85

    Dell Converged Enhanced Ethernet Administrator ’s Guide 67 53-1002116-01 Link aggregatio n overview 7 The Dell M8428-k switch interoperat es with all of the major Layer 2/La yer 3 aggregation rout ers including Foundr y Networks, Cisco Systems, Brocade Communications Systems and Forc e10 Networks. FIGURE 4 Configuring LAGs for a top-of-the-rack C[...]

  • Pagina 86

    68 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Link aggregation overview 7 Link Aggregation Control Protocol Link Aggregation Contr ol Prot ocol (LA CP) is an IE EE 802.3ad standards-based pr otocol that allows two par tner systems to dynamically negotiat e attrib utes of physical links between them t o form logical trun[...]

  • Pagina 87

    Dell Converged Enhanced Ethernet Administrator ’s Guide 69 53-1002116-01 LACP configuration guidelines a nd restrictions 7 LACP configuration guidelines and restrictions This section applies to standards-based and Dell -pr oprietar y LAG configurations ex cept where specifically not ed otherw ise. Follo w thes e LACP configuration guidelines and [...]

  • Pagina 88

    70 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 LACP configuration and manageme nt 7 3. Ent er t he no shutdown command to enable the CEE int er face. 4. Ent er t he channel-group command t o configure the LA CP for th e CEE inter face. switch(conf-if)# channel-group 4 mode active type Dell Configuring the LACP system pri[...]

  • Pagina 89

    Dell Converged Enhanced Ethernet Administrator ’s Guide 71 53-1002116-01 LACP configuration and management 7 2. Ent er the por t-channel su b-mode. switch(conf-if-te-0/1)# interface port-channel 63 3. Configure the minimum links. switch(conf-if-po-63)# minimum-links 3 Configuring interface tracking The track interface command lets you track one o[...]

  • Pagina 90

    72 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 LACP troubleshooting tips 7 Clearing LACP counter stat istics on all LAG groups T o clear LA CP counter statistics, ent er the clear command to clear the LA CP counter statistics f or all LAG gr oups . Example switch# clear lacp counters Displaying LACP information Use the s[...]

  • Pagina 91

    Dell Converged Enhanced Ethernet Administrator ’s Guide 73 53-1002116-01 LACP troubleshooting tips 7 • Make sure that LA CPDUs are being received an d transmitted on bo th ends of the link and there are no err or PDUs. This can be v erified by ent ering the show lacp por t-channel-num counte rs command and looking at the r x and tx statis tics.[...]

  • Pagina 92

    74 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 LACP troubleshooting tips 7[...]

  • Pagina 93

    Dell Converged Enhanced Ethernet Administrator ’s Guide 75 53-1002116-01 Chapter 8 Configuring LLDP using the CEE CLI In this chapter • LLDP ov er view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 • Lay er 2 topology mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Pagina 94

    76 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Layer 2 topology mapping 8 Layer 2 topology mapping The LLDP pr otocol le ts network manageme nt sy stems accurat ely discover and mode l Lay er 2 network t opologies. As LLDP devices transmit and receive advertisements, the devices store information the y discover a bout th[...]

  • Pagina 95

    Dell Converged Enhanced Ethernet Administrator ’s Guide 77 53-1002116-01 Layer 2 topology mapping 8 - Por t VLANID TL V—Indica tes the por t VLA N ID (PVID) that is associated with an unt agged or priority tagged data frame received on the VLAN por t. - PPVLAN ID TL V—Indicat es the por t- and prot ocol-- based VLAN ID (PPVID) that is associa[...]

  • Pagina 96

    78 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 DCBX overview 8 DCBX overview Storage traf fic requires a lossless communicatio n which is pro vided by CEE. The Data Center Bridging (DCB) Capability Ex change Prot ocol (DCB X) is used to e xchange CEE-related paramet ers with neighbors to achie ve more ef fi cient sche du[...]

  • Pagina 97

    Dell Converged Enhanced Ethernet Administrator ’s Guide 79 53-1002116-01 DCBX interaction with other vendor devices 8 Priority Flow Control (PFC) With PFC, it is impor tant to pr ovide lossless frame delivery for certain traf fic classes while maintaining existing LAN behavior f or other traf fic classes on the converged link. This differs from t[...]

  • Pagina 98

    80 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Default LLDP configuration 8 Default LLDP configuration Ta b l e 14 lists the default LLDP c onfiguration. LLDP configuration and management NOTE Y ou need to ent er either the copy running-config startup-config command or the write memory command to sa ve yo ur configuratio[...]

  • Pagina 99

    Dell Converged Enhanced Ethernet Administrator ’s Guide 81 53-1002116-01 LLDP configuration and management 8 Configuring LLDP global command options Af te r en te r i ng t h e prot ocol lldp command from global co nfiguration mode, you are in LL DP configuration mo de which is designated with the switch(conf-lldp)# prompt. Using the ke ywords in [...]

  • Pagina 100

    82 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 LLDP configuration and management 8 Enabling and disabling the receivin g and transmitting of LLDP frames By default both transmit an d receiv e f or LLDP frames is enabled. T o enable or disable the receiving (rx) and transmitting (tx) of LLDP frames, pe r f orm the fo llow[...]

  • Pagina 101

    Dell Converged Enhanced Ethernet Administrator ’s Guide 83 53-1002116-01 LLDP configuration and management 8 3. Adver tise the optional LLDP TL Vs. switch(conf-lldp)# advertise optional-tlv [port-description |system-name | system-capabilities | system-description | management-address] Configuring the advertisement of LLDP DCBX -related TLVs NOTE [...]

  • Pagina 102

    84 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 LLDP configuration and management 8 T o configure LLDP profiles, p er f orm the fo llo wing steps from Privile ged EXEC mode. 1. Ente r t h e configure term inal command to access globa l configuration mode. 2. Ent er LLDP conf iguration mode. switch(config)# protocol lldp 3[...]

  • Pagina 103

    Dell Converged Enhanced Ethernet Administrator ’s Guide 85 53-1002116-01 LLDP configuration and management 8 2. Apply an LLDP profile to the int er face. The f ollowing example applies the LLDP pr ofile “network_standar d” to the current interface. switch(conf-if-te-0/10)# lldp profile network_standard 3. Configure the FCoE priority bits for [...]

  • Pagina 104

    86 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 LLDP configuration and management 8[...]

  • Pagina 105

    Dell Converged Enhanced Ethernet Administrator ’s Guide 87 53-1002116-01 Chapter 9 Configuring ACLs using the CEE CLI In this chapter • A CL overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 7 • Default A CL configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Pagina 106

    88 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Default ACL configurati on 9 MA C ACLs are supported on the f ollowing interface types: • Physical int er faces • Logical inter faces (LAGs) • VLANs Default ACL configuration Ta b l e 1 5 lists the def ault ACL configuration. ACL configuration guidelines and restrictio[...]

  • Pagina 107

    Dell Converged Enhanced Ethernet Administrator ’s Guide 89 53-1002116-01 ACL configuration and management 9 In this ex ample, the name of the standard MA C AC L is “test_0 1.” switch(config)# mac access-list standard test_01 switch(conf-macl-std)# 3. Ent er t he deny command t o create a rule in the MA C AC L t o drop traffic with the source [...]

  • Pagina 108

    90 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 ACL configuration and management 9 If you need t o add more rules between existing ru les than the current sequence numbering allo ws, you can us e t he resequence command to reassign sequence nu mbers. For detailed inf ormation, see “R eordering the sequence numbers in a [...]

  • Pagina 109

    Dell Converged Enhanced Ethernet Administrator ’s Guide 91 53-1002116-01 ACL configuration and management 9 T o reorder the rules in a MAC A CL, per form the f ollowing task fr om Privileged EXEC mode. 1. Ente r t h e resequence command to assign seq uence numb ers to the rules contained in the MAC A C L. switch# resequence access-list mac test_0[...]

  • Pagina 110

    92 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 ACL configuration and management 9[...]

  • Pagina 111

    Dell Converged Enhanced Ethernet Administrator ’s Guide 93 53-1002116-01 Chapter 10 Configuring QoS using the CEE CLI In this chapter • QoS ov er view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 • Re writing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Pagina 112

    94 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Rewriting 10 • Scheduling—When multiple queues are activ e and cont ending for output on a common physical port the scheduling al gorithm selects the ord er the queues are serviced. Scheduling algorithms include Strict Prio rity (SP) and Deficit W eighted R ound Robin (D[...]

  • Pagina 113

    Dell Converged Enhanced Ethernet Administrator ’s Guide 95 53-1002116-01 Queueing 10 Ta b l e 16 presents the La yer 2 QoS untrust e d user priority generation table. NOTE Non-tagged Ethernet frames are int erpreted as incoming CoS value of 0 (zer o). Y ou can ov erride the default user -priority mapping by applying e xplicit user-priority mappin[...]

  • Pagina 114

    96 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Queueing 10 T o configure the QoS trust mode, perform the f ollowing steps fr om Privileged EXEC mode. 1. Ent er globa l configuration mode. switch# configure terminal 2. Specify the 1 0 -gigabit Ethernet interface. switch(config)# interface intengigabitethernet 0/2 3. Set t[...]

  • Pagina 115

    Dell Converged Enhanced Ethernet Administrator ’s Guide 97 53-1002116-01 Queueing 10 Applying a CoS-to-CoS mutation QoS map T o apply a CoS-to-CoS mutation QoS map, per for m the f ollowing steps from Privileged EXEC mode. 1. Ent er globa l configuration mode. switch# configure terminal 2. Specify the 1 0 -gigabit Ethernet interface. switch(confi[...]

  • Pagina 116

    98 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Queueing 10 Y ou are allowed to override these default traf fic class mappings per por t. Once the traf fic class mapping has been resolved it is applied consistently across an y queueing incu rred on the ingress and the egress ports. Multicast traffic Fa b r i c O S v 6 . 3[...]

  • Pagina 117

    Dell Converged Enhanced Ethernet Administrator ’s Guide 99 53-1002116-01 Queueing 10 The f ollowing example cr eates CoS-to- T raf fic-Class QoS map to map CoS 0 (best ef for t) to T raf fic Class 1 and CoS 1 t o below best effor t T raf fic Class 0, all other CoS go through unchanged. This mapping matches the default behavior recommended in IEEE[...]

  • Pagina 118

    100 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Congestion control 10 Congestion control Queues can begin filling up due t o a number of re asons, such as over subscription of a link or backpressure fr om a downstream de vice. Sustai ned, large q ueue buildups generally indicate congestion i n the network and can af fect[...]

  • Pagina 119

    Dell Converged Enhanced Ethernet Administrator ’s Guide 101 53-1002116-01 Congestion control 10 Changing the Tail Drop threshold T o change the T ail Drop threshold, perform the f ollowing steps from Privileged EXEC mode. 1. Ent er globa l configuration mode. switch# configure terminal 2. Change the T ail Drop threshold f or each multic ast traf [...]

  • Pagina 120

    102 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Congestion control 10 Enabling Ethernet Pause T o enable Ethernet Pause, per form the f ollowing steps fr om Privileged EXEC mode. 1. Ent er globa l configuration mode. switch# configure terminal 2. Specify the 1 0 -gigabit Ethernet interface. switch(config)# interface inte[...]

  • Pagina 121

    Dell Converged Enhanced Ethernet Administrator ’s Guide 103 53-1002116-01 Multicast ra te limiting 10 2. Specify the 1 0-gigabit Ethernet inter face. switch(config)# interface intengigabitethernet 0/2 3. Enable an Ethernet PFC on the interface. switch(conf-if-te-0/2)# qos flowcontrol pfc 3 tx on rx on The f ollowing example enables an int er fac [...]

  • Pagina 122

    104 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Scheduling 10 Enter configuration commands, one per line. End with CNTL/Z. switch(config)# qos rcv-queue multicast rate-limit 10000 switch(config)#end 3. En te r t he co py c om ma n d to save t h e ru n ni ng -c on f ig f il e to th e s ta r tu p- co n fi g f i le . switch[...]

  • Pagina 123

    Dell Converged Enhanced Ethernet Administrator ’s Guide 105 53-1002116-01 Scheduling 10 Figure 8 describes the frame scheduling order f or a WRR scheduler servicin g two WRR queues. The higher numbered queue is considered higher priori ty (WRR2) and the weights indicate the network bandwidth should be allocated in a 2:1 ratio between the tw o que[...]

  • Pagina 124

    106 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Scheduling 10 Figure 9 shows that ext ending the frame scheduler to a h ybrid SP+WRR system is f airly straightf or ward. All SP queues are considered strict ly higher priority than WRR so they are ser viced first. Once all SP q ueues are drained, then the normal WRR schedu[...]

  • Pagina 125

    Dell Converged Enhanced Ethernet Administrator ’s Guide 107 53-1002116-01 Converged Enhanced Ethern et map config uration 10 Once the multicast traffic class equivalence mappi ng has been applied, then scheduling and any scheduler configuration are inherited fr om the equiv alent unicast traf fic class. See Ta b l e 2 0 on page 1 05 for details o[...]

  • Pagina 126

    108 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Converged Enhanced Ethernet map configuration 10 NOTE Only a single CoS can be mapped to a PFC-enab led priority queue. The Co S number must be identical to th e priority queue numb er . If your configuration violates this restrictio n an error message displays and the Prio[...]

  • Pagina 127

    Dell Converged Enhanced Ethernet Administrator ’s Guide 109 53-1002116-01 Converged Enhanced Ethern et map config uration 10 Creating a CEE map Only a single CEE map is allowed, which is creat ed aut omatically with the name “default.” Y ou are no t be a b le to d el e te or r e n am e t hi s m ap . T o create a CEE map, per form the f ollowi[...]

  • Pagina 128

    110 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Converged Enhanced Ethernet map configuration 10 Defining a priority-table map T o define a priority-table map, per form the follo wing steps fr om Privileged EXEC mode. 1. Ent er globa l configuration mode. switch# configure terminal 2. Spe cify the name of the CEE map to [...]

  • Pagina 129

    Dell Converged Enhanced Ethernet Administrator ’s Guide 111 53-1002116-01 Chapter 11 Configuring 802.1x Por t Authentication In this chapter • 802. 1x protocol o verview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 • 802. 1x configuration guidelines and restrictions . . . . . . . . . . . . . . . . . . . . [...]

  • Pagina 130

    112 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 802.1x authentication configuration tasks 11 802.1x authentication configuration tasks The tasks in this section describe the common 802. 1x operations that you will need to perform. For a complete description of all the available 802. 1x CLI commands for the Dell FCoE hard[...]

  • Pagina 131

    Dell Converged Enhanced Ethernet Administrator ’s Guide 113 53-1002116-01 Interface-specific administrative tasks for 802.1x 11 Configuring 802.1x on specific interface ports T o configure 802. 1x por t authentication on a spec ific interface por t, per form the f ollowing steps from Privileged EXEC mode. Repeat this task f or each int er face po[...]

  • Pagina 132

    114 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Interface-specific admini strative tasks for 802.1x 11 switch(conf-if-te-0/16)# dot1x timeout re-authperiod 4000 Disabling 802.1x on specific interface ports T o disable 802. 1x authentication on a specific int er face por t, per form the f o llowing st eps from Privileged [...]

  • Pagina 133

    Dell Converged Enhanced Ethernet Administrator ’s Guide 115 53-1002116-01 Chapter 12 Configuring sFlow using the CEE CLI In this chapter • sFlow pr otocol o ver view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 15 • Configuring the sFlow pr otocol globally . . . . . . . . . . . . . . . . . . . . . . . . . [...]

  • Pagina 134

    116 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Configuring the sFlow protocol globally 12 Configuring the sFlow protocol globally Dell recommends that you g lobally configure sF low on the switch first, then make custom alterations t o specific interface por ts. For details, see “Interface-specific administrativ e tas[...]

  • Pagina 135

    Dell Converged Enhanced Ethernet Administrator ’s Guide 117 53-1002116-01 Interface-specific admini strative tasks for sFlow 12 T o disable sFlow on a specific in terface, per form the f ollowing st eps in global configuration mode. 1. Enter interface mode for the por t switch(config)#interface intengigabitethernet 0/12 2. Disable sFlow on the in[...]

  • Pagina 136

    118 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Interface-specific admini strative tasks for sFlow 12[...]

  • Pagina 137

    Dell Converged Enhanced Ethernet Administrator ’s Guide 119 53-1002116-01 Chapter 13 Configuring Port Mirroring using the CEE CLI In this chapter • Port Mirroring pr otocol ov erview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 9 • Configuring ingress P or t Mirroring . . . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Pagina 138

    120 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Configuring ingress Port Mirroring 13 Configuring ingress Port Mirroring T o configure Por t Mirroring for incoming packets only , per form the follo wing s teps in global configuration mode. 1. Open a monit or sess ion and assign a session number switch(config)# monitor se[...]

  • Pagina 139

    Dell Converged Enhanced Ethernet Administrator ’s Guide 121 53-1002116-01 Deleting a Port Mirroring connection from a session 13 2. Configure the source por t and the destination port, with the both paramet er for all pack ets. The destination por t is always an e xternal por t. switch(config-mon-sess-1)# source intengigabitethernet 0/1 destinati[...]

  • Pagina 140

    122 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Deleting a Port Mirroring session 13[...]

  • Pagina 141

    Dell Converged Enhanced Ethernet Administrator ’s Guide 123 53-1002116-01 Chapter 14 Configuring RMON using the CEE CLI In this chapter • RMON ov er view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 • RMON configuration and management . . . . . . . . . . . . . . . . . . . . . . . . . . . . [...]

  • Pagina 142

    124 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 RMON configuration and management 14 2. Configure the RMON alarms. The follo wing example creat es an alarm that tests e ver y sample for a rising threshold switch(config)# rmon alarm 5 1.3.6. 1.2. 1. 16. 1. 1. 1.5.65535 interval 30 absolute rising-threshold 95 event 27 own[...]

  • Pagina 143

    Dell Converged Enhanced Ethernet Administrator ’s Guide 125 53-1002116-01 RMON configuration and management 14 switch(config)# interface intengigabitethernet 0/1 3. Enable the CEE int er face. switch(conf-if-te-0/1)# no shutdown 4. Configure RMON gr oup stat istics on the int er face. switch(conf-if-te-0/1)# rmon collection stats 200 owner john_s[...]

  • Pagina 144

    126 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 RMON configuration and management 14[...]

  • Pagina 145

    Dell Converged Enhanced Ethernet Administrator ’s Guide 127 53-1002116-01 Chapter 15 Configuring IGMP In this chapter • About IGMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 7 • Configuring IGMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Pagina 146

    128 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Configuring IGMP 15 Multicast routing Multicast rout ers use IGMP to learn which gro ups ha ve members on each of their attached ph ysical networks. A multicast router k eeps a list of multic ast group memberships f or each attached networ k, and a timer for each membersh i[...]

  • Pagina 147

    Dell Converged Enhanced Ethernet Administrator ’s Guide 129 53-1002116-01 Monitoring IGMP 15 IGMP sno oping querier send s out IGMP queries to trigger IGMP responses from switches that wish to receiv e IP multicast traf fic. IGMP snooping listens for these responses to map the appropriate forwarding addresses. Refe r to th e CEE Comm and Ref eren[...]

  • Pagina 148

    130 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Monitoring IGMP 15 4. Use the s h ow i p i gm p m rou ter to displa y multicast router (mr outer) port related information f or all VLANs, or a specific VLAN. switch# show ip igmp snooping mrouter - or - switch# show ip igmp snooping mrouter interface vlan 1 5. When y ou ha[...]

  • Pagina 149

    Dell Converged Enhanced Ethernet Administrator ’s Guide 131 53-1002116-01 Chapter 16 FCoE configuration using the Fabric OS CLI In this chapter • FCoE configuration guidelines and restrictions . . . . . . . . . . . . . . . . . . . . . . 1 3 1 • Managing and displaying the FCoE configuratio n . . . . . . . . . . . . . . . . . . . . 132 • Man[...]

  • Pagina 150

    132 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Managing and displaying the FCoE configuration 16 Managing and displaying the FCoE configuration FCoE tec hnology bridges the boundar y between th e SAN and LAN sections of y our network. FCoE configuration tasks require mostly configu rat ion of the inte r face ports on th[...]

  • Pagina 151

    Dell Converged Enhanced Ethernet Administrator ’s Guide 133 53-1002116-01 Managing and displaying the FCoE login configuration 16 T o configure FIP m ulticast adver tisement inter vals, per form the f ollowing task . Clearing logins T o clear logins, per form the f ollowing task. Displaying FCoE configuration-related information T o display FCoE-[...]

  • Pagina 152

    134 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Managing and displaying the FCoE login configuration 16 Perform one of the following tasks to t oggle the availability of FCoE login configuratio n management. Displaying or aborting the current configuration transaction NOTE The configuration change s created using the fco[...]

  • Pagina 153

    Dell Converged Enhanced Ethernet Administrator ’s Guide 135 53-1002116-01 Creating and managing the FCoE login group configuration 16 Displaying the FCoE login configuration T o display the F CoE login configuration, per form the f ollowing tasks. Saving the current FCoE configuration T o sav e the current FCoE configuration, per form the f ollow[...]

  • Pagina 154

    136 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Creating and managing the FCoE login group configuration 16 T o create an FCoE login group, perform the f ollowing task. Modifying the FCoE login group device list T o add or remov e VN_por t devices from the F CoE login group, perform the f ollowing tasks. Deleting an FCoE[...]

  • Pagina 155

    Dell Converged Enhanced Ethernet Administrator ’s Guide 137 53-1002116-01 Creating and managing the FCoE login group configuration 16 Renaming an FCoE login group T o rename an FCoE login group, per form the f ollowing task. Task Command Rena me an FCoE login group. Syntax is as fo llows: • lgname —Specify the name of the login group from whi[...]

  • Pagina 156

    138 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Creating and managing the FCoE login group configuration 16[...]

  • Pagina 157

    Dell Converged Enhanced Ethernet Administrator ’s Guide 139 53-1002116-01 Chapter 17 CEE configuration management In this chapter • CEE configuration management guidelines and restrictions . . . . . . . . . . . 139 • CEE configuration management tasks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139 • Flash file ma nagement comm[...]

  • Pagina 158

    140 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 CEE configuration managem ent tasks 17 Display the running configuration file T o display the running configuration, per form the f ollowing st eps from Privileged EXEC mo de. 1. Ente r t h e configure term inal command to access globa l configuration mode. 2. Ent er t he s[...]

  • Pagina 159

    Dell Converged Enhanced Ethernet Administrator ’s Guide 141 53-1002116-01 CEE configuration managem ent tasks 17 Archiving the running configuration file This tasks allows you t o archive the running configuration to an archive f older on an FTP site, so that it can be stored without ch anging the star tup configuration. T o archiv e the running [...]

  • Pagina 160

    142 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Flash file manage ment commands 17 Restore a startup configuration file from Flash This task also works f or running configuration files. T o restore the star tup configuration, per form the following st eps from Privileged EXEC mode. 1. Ente r t h e configure term inal com[...]

  • Pagina 161

    Dell Converged Enhanced Ethernet Administrator ’s Guide 143 53-1002116-01 Debugging and logging commands 17 NOTE Use of the flash:// prefix is optional. Debugging and logging commands Ta b l e 2 6 describes the tasks related to debuggi ng and logging commands on the switch. The Con verged Enhanced Ethernet Command R eference contains complete inf[...]

  • Pagina 162

    144 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 Debugging and logging commands 17[...]

  • Pagina 163

    Dell Converged Enhanced Ethernet Administrator ’s Guide 145 53-1002116-01 Index Symbols Numerics 8000 CEE switch congestion control and queuing , 6 flow control , 8 Layer 2 Ethernet , 3 Layer 2 forwarding , 3 loop-free , 5 tagging , 4 trunking , 8 802.1x LAG , 27 , 111 overview , 27 , 111 timeouts , 113 A Access Control Lists See ACL access inter[...]

  • Pagina 164

    146 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 classifier groups, VLAN , 39 classifier rules, VLAN , 38 CLI, CEE accessing , 15 command compl etion , 19 command modes , 15 console and VTY (line) configuration , 17 EXEC , 16 feature configuration , 17 global configuration , 16 interface configuration , 16 Privileged EXEC[...]

  • Pagina 165

    Dell Converged Enhanced Ethernet Administrator ’s Guide 147 53-1002116-01 FIP FC zoning , 11 FCoE login , 10 FCoE logout , 10 FIP discovery , 8 login , 9 logincfg , 11 logout , 10 name server , 11 registered state change notification (RSCN) , 12 FLOGI , 1 flow control , 8 flushing MAC addresses , 57 frame classification, incoming , 5 G guard root[...]

  • Pagina 166

    148 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 LLDP configuration guidel ines and restrictions , 79 configuration procedur es clearing LLDP-related information , 85 disabling LLDP globally , 80 displaying LLDP-related information , 85 enabling LLDP globally , 80 global command options , 81 important notes , 80 interface[...]

  • Pagina 167

    Dell Converged Enhanced Ethernet Administrator ’s Guide 149 53-1002116-01 querier interval , 128 MRT , 128 VLAN , 128 queuing congestion c ontrol , 6 FCoE , 12 QoS , 94 R RADIUS , 27 , 111 Rapid Spanning Tree Protocol See RSTP RBAC permissions region name, specifying for MSTP , 56 registered state notifi cation protocol (RSCN) , 12 revision numbe[...]

  • Pagina 168

    150 Dell Converged Enhanced Ethernet Administrator ’s Guide 53-1002116-01 VLAN applying a MAC ACL , 91 configuration guidel ines and restrictions , 33 configuration procedur es clearing VLAN counters , 40 configuring a CEE interface as a Layer 2 sw itch port , 36 configuring a CEE interface as an access or trunk interface , 36 configuring the MTU[...]