Warning: mysql_fetch_array() expects parameter 1 to be resource, boolean given in /home/newdedyk/domains/bkmanuals.com/public_html/includes/pages/manual_inc.php on line 26
Compaq 113803-001 manuale d’uso - BKManuals

Compaq 113803-001 manuale d’uso

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162

Vai alla pagina of

Un buon manuale d’uso

Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Compaq 113803-001. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Compaq 113803-001 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.

Che cosa è il manuale d’uso?

La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Compaq 113803-001 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.

Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.

Quindi cosa dovrebbe contenere il manuale perfetto?

Innanzitutto, il manuale d’uso Compaq 113803-001 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Compaq 113803-001
- nome del fabbricante e anno di fabbricazione Compaq 113803-001
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Compaq 113803-001
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti

Perché non leggiamo i manuali d’uso?

Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Compaq 113803-001 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Compaq 113803-001 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Compaq in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Compaq 113803-001, come nel caso della versione cartacea.

Perché leggere il manuale d’uso?

Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Compaq 113803-001, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.

Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Compaq 113803-001. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.

Sommario del manuale d’uso

  • Pagina 1

    ProLiant 3000 Servers For Use With Intel 350 MHz or Greater Processor-Based Servers Only Maintenance and Service Guide First Edition (February 1999 ) Part Number 113803-001 Spare Part Number 114651-001 Compaq Computer Corporation[...]

  • Pagina 2

    Notice The information in this publication is subject to change without notice. COMPAQ COMPUTER CORPORATION SHALL NOT BE LIABLE FOR TECHNICAL OR EDITORIAL ERRORS OR OMISSIONS CONTAINED HEREIN, NOR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE FURNISHING, PERFORMANCE, OR USE OF THIS MATERIAL. THIS INFORMATION IS PROVIDED “AS IS” AND[...]

  • Pagina 3

    iii Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Contents About This Guide Symbols in Text......................................................................................................................... vii Compaq Technician Notes............................[...]

  • Pagina 4

    iv Chapter 3 Diagnostic Tools Default Configuration .......................................................................................................... ..... 3-2 Default Configuration Messages ....................................................................................... 3-2 Utilities Access .........................................[...]

  • Pagina 5

    v Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Chapter 4 Connectors, Switches, Jumpers, and LEDs Connectors ................................................................................................................................4-1 Rear Panel Connectors .....[...]

  • Pagina 6

    vii Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide About This Guide This Maintenance and Service Guide is a troubleshooting guide that can be used for reference when servicing Compaq ProLiant 3000 Servers. WARNING: To reduce the risk of personal injury from electrical [...]

  • Pagina 7

    viii About This Guide WARNING: To reduce the risk of personal injury from electrical shock and hazardous energy levels, do not exceed the level of repair specified in these procedures. Because of the complexity of the individual boards and subassemblies, do not attempt to make repairs at the component level or to make modifications to any printed w[...]

  • Pagina 8

    ix Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Telephone Numbers For the name of your nearest Compaq Authorized Reseller: In the United States, call 1-800-345-1518 In Canada, call 1-800-263-5868 For Compaq technical support: In the United States and Canada, call 1-8[...]

  • Pagina 9

    1-1 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Chapter 1 Illustrated Parts Catalog This chapter provides the illustrated parts breakdown and a spare parts list for Compaq ProLiant 3000 Servers. See Table 1-1 for the names of referenced spare parts. External Compone[...]

  • Pagina 10

    1-2 Illustrated Parts Catalog System Components Exploded View 12 10 26 13 1 21 9 15 19 14 43 35 23 17 16 20 22 44 40 Figure 1-2. Exploded view of Compaq ProLiant 3000 Server system components[...]

  • Pagina 11

    1-3 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Spare Parts List Table 1-1 Spare Parts List - Compaq ProLiant 3000 Servers Ref Description Spare Part # CHASSIS 1 Chassis 306574-001 2 Side Access Panel 298364-001 3 Access Panel Kit a) U-Channel Access Panel b) Top Ac[...]

  • Pagina 12

    1-4 Illustrated Parts Catalog Spare Parts List Continued Ref Description Spare Part # MASS STORAGE DEVICES 22 32x IDE CD-ROM Drive with Tray 328707-001 23 1.44-MB Diskette Drive 160788-201 MEMORY 24 32-MB SDRAM Dual Inline Memory Module (DIMM) (100 Mhz) 317747-001 * 25 64-MB SDRAM Dual Inline Memory Module (DIMM) (100 Mhz) 317745-001* 26 128-MB SDR[...]

  • Pagina 13

    1-5 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Spare Parts List Continued Ref Description Spare Part # OPTIONS 40 Smart Array 3200 Controller 340855-001 41 Processor, 450/100 MHz 179780-001 * 42 SCSI Duplex Hot-Plug Drive Cage 306572-001 * 43 Ultra2 Drive Cage 3670[...]

  • Pagina 14

    2-1 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Chapter 2 Removal and Replacement Procedures This chapter provides subassembly/module-level removal and replacement procedures for ProLiant 3000 Servers. After completing all necessary removal and replacement procedure[...]

  • Pagina 15

    2-2 Removal and Replacement Procedures Symbols in Equipment WARNING: Any surface or area of the equipment marked with these symbols indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists. To reduce risk of injury from a hot component, allow the surface to cool before touching. WARNING[...]

  • Pagina 16

    2-3 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Rack Warnings WARNING: Always load the heaviest item first and load the rack from the bottom up. This makes the rack “bottom-heavy” and helps prevent the rack from becoming unstable. WARNING: To reduce the risk of [...]

  • Pagina 17

    2-4 Removal and Replacement Procedures Server Warnings and Precautions WARNING: To reduce the risk of personal injury or damage to the server, you must support the server when loading or unloading it from the rack. The server is not attached to the support rails of the rack and may fall if not supported when extended from the rack. WARNING: To redu[...]

  • Pagina 18

    2-5 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Locking Casters To remove the locking casters: 1. Perform the preparation procedures. See “Preparation Procedures” earlier in this chapter. 2. Place the server on its side. 3. Remove the three T-25 screws securing [...]

  • Pagina 19

    2-6 Removal and Replacement Procedures Caster Mounting Support To remove the caster mounting support: 1. Perform the preparation procedures. See “Preparation Procedures” earlier in this chapter. 2. Remove the casters. See “Locking Casters” earlier in this chapter. 3. Remove the four T-15 screws securing the caster mounting support to the se[...]

  • Pagina 20

    2-7 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Front Bezel Door To remove the front bezel door (tower model only): 1. Swing the front bezel door open approximately 45 degrees. 2. Lift the front bezel door up, then pull it away from the chassis. COMPACT Figure 2-3. [...]

  • Pagina 21

    2-8 Removal and Replacement Procedures Front Fixed Bezel The front fixed bezel must be removed to replace the power switch. To remove the front fixed bezel (tower model only): 1. Perform the preparation procedures. See “Preparation Procedures” earlier in this chapter. 2. Open the front bezel door. 3. Remove the seven T-15 screws securing the fr[...]

  • Pagina 22

    2-9 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Rack-Mount Bezel The rack-mount bezel (rack model only) must be removed to replace the power switch. To remove the rack-mount bezel: 1. Perform the preparation procedures. See “Preparation Procedures” earlier in th[...]

  • Pagina 23

    2-10 Removal and Replacement Procedures Top Access Panel WARNING: To reduce the risk of personal injury from hot surfaces, allow the internal system components to cool before touching them. To remove the top access panel (tower model only): 1. Perform the preparation procedures. See “Preparation Procedures” earlier in this chapter. 2. Open the [...]

  • Pagina 24

    2-11 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide U-Channel Access Panel The U-channel access panel is removed for replacement only. To remove the U-channel access panel: 1. Perform the preparation procedures. See “Preparation Procedures” earlier in this chapter.[...]

  • Pagina 25

    2-12 Removal and Replacement Procedures Side Access Panel WARNING: To reduce the risk of personal injury from hot surfaces, allow the internal system components to cool before touching them. To remove the side access panel: 1. Perform the preparation procedures. See “Preparation Procedures” earlier in this chapter. 2. Loosen the two screws at t[...]

  • Pagina 26

    2-13 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Integrated Management Display (IMD) The IMD is removed for replacement only. NOTE : The IMD is shipped standard in the rack-mount model and as an option in the tower model. The tower model is shown. To remove the IMD:[...]

  • Pagina 27

    2-14 Removal and Replacement Procedures 7. Press the four latches on the rear of the IMD 3 . 8. Pull the IMD from the front of the server 4 . COMPACT 3 4 3 3 3 Figure 2-10. Removing the Integrated Management Display NOTE : Drive cage may may not be as illustrated. Reverse steps 1 through 8 to replace the IMD. CAUTION: Make sure all power and signal[...]

  • Pagina 28

    2-15 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Fans Compaq ProLiant 3000 Servers ship standard with two 120-mm front fans (in positions 1 and 3) and one 92-mm rear fan (in position 5). The figure below shows the location of the front and rear fans in the ProLiant [...]

  • Pagina 29

    2-16 Removal and Replacement Procedures Front Fan(s) The front fans are removed for replacement or to replace the Integrated Management Display, the fan baffle, or the drive cage. To remove a front fan(s): 1. Perform the preparation procedures. See “Preparation Procedures” earlier in this chapter. 2. Remove the side access panel. See “Side Ac[...]

  • Pagina 30

    2-17 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Fan Baffle The fan baffle should only be removed if damaged. To remove the fan baffle: 1. Perform the preparation procedures. See “Preparation Procedures” earlier in this chapter. 2. Remove the side access panel. [...]

  • Pagina 31

    2-18 Removal and Replacement Procedures Rear Fan Remove the rear fan for replacement or for upgrading to another model fan. To remove the rear fan: 1. Perform the preparation procedures. See “Preparation Procedures” earlier in this chapter. 2. Remove the side access panel. See “Side Access Panel” earlier in this chapter. 3. Disconnect the r[...]

  • Pagina 32

    2-19 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Removable Media and Mass Storage Devices Compaq ProLiant 3000 Servers can house up to 12 mass storage devices, including: ■ Preinstalled 3.5-inch 1.44-MB diskette drive and an IDE CD-ROM drive ■ Two half-height dr[...]

  • Pagina 33

    2-20 Removal and Replacement Procedures Drive Cage Assemblies ProLiant 3000 Servers ship with either Wide-Ultra or Ultra2 drive cage assemblies. The Wide- Ultra and the Ultra2 drive cage assemblies include the drive cage and backplane board. Wide-Ultra Hot-Plug Drive Cage To remove the Wide-Ultra drive cage assembly: 1. Perform the preparation proc[...]

  • Pagina 34

    2-21 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Simplex Enabler Board The Simplex Enabler board is removed when changing the Wide-Ultra drive cage assembly to Duplex mode. To remove the Simplex Enabler board: 1. Perform the preparation procedures. See “Preparatio[...]

  • Pagina 35

    2-22 Removal and Replacement Procedures Ultra2 Hot-Plug Drive Cage To remove the Ultra2 hot-plug drive cage assembly: 1. Perform the preparation procedures. See “Preparation Procedures” earlier in this chapter. 2. Remove the front bezel door (tower model only). See “Front Bezel Door” earlier in this chapter. 3. Remove the side access panel.[...]

  • Pagina 36

    2-23 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Hard Drives Wide-Ultra Hot-Plug Hard Drives Wide-Ultra hot-plug hard drives are removed for replacement or for upgrade to a larger drive . To remove a Wide-Ultra hot-plug hard drive: 1. Open the front bezel door (towe[...]

  • Pagina 37

    2-24 Removal and Replacement Procedures Ultra2 Hot-Plug Hard Drives Compaq ProLiant 3000 Servers may ship with Ultra2 hot-plug hard drives. Ultra2 hot-plug hard drives are removed for replacement or for upgrade to a larger drive . CAUTION: Do not remove a hot-plug drive if any of the online LEDs are green. To remove an Ultra2 hot-plug hard drive: 1[...]

  • Pagina 38

    2-25 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Removable Media Devices The removable media area contains the standard CD-ROM drive and two available half-height drive bays. Removable Media Panel The removable media panel must be removed to access the removable med[...]

  • Pagina 39

    2-26 Removal and Replacement Procedures Removable Media Drives The removable media drives are removed for replacement or when installing another media device. To remove a drive from the removable media area, including the CD-ROM drive and tape drive: 1. Perform the preparation procedures. See “Preparation Procedures” earlier in this chapter. 2.[...]

  • Pagina 40

    2-27 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Diskette Drive The diskette drive is removed for replacement or when installing another media device. To remove the diskette drive: 1. Perform the preparation procedures. See “Preparation Procedures” earlier in th[...]

  • Pagina 41

    2-28 Removal and Replacement Procedures Cable Folding and Routing Diagrams Figure 2-24. CD-ROM drive cable folding and routing diagram Figure 2-25. Diskette drive cable folding and routing diagram[...]

  • Pagina 42

    2-29 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Figure 2-26. Array Controller removable media cable folding and routing diagram[...]

  • Pagina 43

    2-30 Removal and Replacement Procedures Memory Compaq ProLiant 3000 Servers ship standard with either 128 MB or 256 MB Synchronous DRAM (SDRAM) Dual Inline Memory Modules (DIMMs)installed in the DIMM 5 socket location. Memory can be expanded to a maximum of 4 GB. Install SDRAM DIMM modules one at a time in the proper socket. See Figure 2-27 and Tab[...]

  • Pagina 44

    2-31 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Any combination of SDRAM DIMMs can be used as long as the guidelines explained earlier are followed. Examples of possible SDRAM DIMM upgrade combinations are shown below. Table 2-2 Examples of SDRAM DIMM Upgrade Combi[...]

  • Pagina 45

    2-32 Removal and Replacement Procedures To remove an SDRAM DIMM: 1. Perform the preparation procedures. See “Preparation Procedures” earlier in this chapter. 2. Remove the top access panel. See “Top Access Panel” earlier in this chapter. 3. Remove any expansion boards above the SDRAM DIMM socket. 4. Press both SDRAM DIMM socket latches outw[...]

  • Pagina 46

    2-33 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Smart Array 3200 Controller The Smart Array 3200 Controller is removed for replacement or when replacing the I/O board or the drive cage assembly. To remove the Smart Array 3200 Controller: 1. Perform the preparation [...]

  • Pagina 47

    2-34 Removal and Replacement Procedures Netelligent 10/100 TX UTP PCI Controller The Compaq Netelligent 10/100 TX UTP network controller is removed for replacement or to access the system IO board. To remove a Netelligent 10/100 TX UTP PCI controller: 1. Perform the preparation procedures. See “Preparation Procedures” earlier in this chapter. [...]

  • Pagina 48

    2-35 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Processor Compaq ProLiant 3000 Servers support up to two 500 MHz or greater Intel Pentium III Xeon processors with corresponding processor power modules and memory banks. To remove a processor: 1. Perform the preparat[...]

  • Pagina 49

    2-36 Removal and Replacement Procedures Processor Power Module To remove a processor power module: 1. Perform the preparation procedures. See “Preparation Procedures” earlier in this chapter. 2. Remove the side access panel. See “Side Access Panel” earlier in this chapter. 3. Remove the top access panel. See “Top Access Panel” earlier i[...]

  • Pagina 50

    2-37 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Hot-Plug Power Supply Compaq ProLiant 3000 Servers ship with one 500/750-watt hot-plug power supply 1 . A second, redundant, hot-plug 750-watt power supply is supported as an option and fits into the covered area 2 . [...]

  • Pagina 51

    2-38 Removal and Replacement Procedures NOTE : You do not need to remove power from the unit for a hot-plug power supply replacement in a redundant power supply configuration. WARNING: To reduce the risk of electric shock or damage to the equipment in a single power supply configuration: ■ Unplug the power cord before removing the power supply fr[...]

  • Pagina 52

    2-39 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Power Supply Blank Panel The power supply blank panel is removed to install a redundant power supply. To remove the power supply blank panel: 1. Perform the preparation procedures. See “Preparation Procedures” ear[...]

  • Pagina 53

    2-40 Removal and Replacement Procedures Power Backplane Board The power backplane board is removed for replacement. To remove the power backplane board: 1. Perform the preparation procedures. See “Preparation Procedures” earlier in this chapter. 2. Remove the power supply(s). See “Hot-Plug Power Supply” earlier in this chapter. 3. Disconnec[...]

  • Pagina 54

    2-41 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide System I/O Board with Subpan The system I/O board with subpan is removed for replacement or to upgrade to a different Compaq model server. To remove the system I/O board with subpan: 1. Perform the preparation procedu[...]

  • Pagina 55

    2-42 Removal and Replacement Procedures Power Switch IMPORTANT: To completely remove all power from the system, you must disconnect the power cord from the server. In systems with multiple power supplies, you must disconnect all power cords to completely remove power from the system. To remove the power switch: 1. Perform the preparation procedures[...]

  • Pagina 56

    2-43 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide External Replacement Battery The external replacement battery is installed if the permanent lithium battery fails. To install the external replacement battery: WARNING: This server contains an internal Lithium Mangane[...]

  • Pagina 57

    2-44 Removal and Replacement Procedures 3. Connect the battery cable to battery header E9 on the system board. 4. Remove the adhesive backing from the hook-and-loop fastener strip on the replacement battery, then place the battery and the hook-and-loop fastener strip as indicated in the following illustration. Figure 2-39. Installing the external r[...]

  • Pagina 58

    3-1 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Chapter 3 Diagnostic Tools This chapter describes software and firmware diagnostic tools available for all Compaq server products. The sections in this chapter are: ■ Default Configuration ■ Access to Compaq Utilit[...]

  • Pagina 59

    3-2 Diagnostic Tools Default Configuration When the system is first powered on, the system ROM detects the un-configured state of the hardware and provides default configuration settings for most devices. By providing this initialization, the system can run Diagnostics and other software applications before running the normal SmartStart and System [...]

  • Pagina 60

    3-3 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Running Compaq Utilities There are three ways to access Compaq Utilities: ■ Run the utilities on the system partition. If the system was installed using SmartStart, the Compaq utilities will automatically be availabl[...]

  • Pagina 61

    3-4 Diagnostic Tools Power-On Self-Test (POST) POST is a series of diagnostic tests that run automatically on Compaq computers when the system is turned on. POST checks the following assemblies to ensure that the computer system is functioning properly: ■ Processors ■ Keyboard ■ Power supply ■ System board ■ Memory ■ Memory expansion bo[...]

  • Pagina 62

    3-5 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem Recommended Action 162-System Options Not Set 2S Configuration incorrect. Run the System Configuration Utility and correc[...]

  • Pagina 63

    3-6 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem Recommended Action 201-Memory Error None RAM failure. Run Diagnostics. Replace failed assembly as indicated. 203-Memory Address Error None RAM failure. Run Diagnostics. Replace failed assembly as indicated. 205-Cache Memory Error No[...]

  • Pagina 64

    3-7 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem Recommended Action 301-Keyboard Error None Keyboard failure. Turn off the computer, then reconnect the keyboard. 301-Keyb[...]

  • Pagina 65

    3-8 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem Recommended Action 703-CMOS reports a coprocessor that has not been detected 2S Coprocessor or configuration error. 1. Run the System Configuration Utility and correct. 2. Replace the coprocessor. 1151-Com Port 1 Address Assignment [...]

  • Pagina 66

    3-9 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem Recommended Action 1702-SCSI cable error detected. System halted. None Incorrect cabling. 1. For integrated SCSI Controll[...]

  • Pagina 67

    3-10 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem Recommended Action 1751-Fixed Disk 1 failed Identify command None Fixed disk drive error. Run the System Configuration Utility and correct. 1760-Fixed Disk 0 does not support Block Mode None Fixed disk drive error. Run the System C[...]

  • Pagina 68

    3-11 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem Recommended Action 1768-Slot x Drive Array -Resuming logical drive expansion process. None SMART-2 Controller error No a[...]

  • Pagina 69

    3-12 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem Recommended Action 1778-Drive Array resuming Automatic Data Recovery process None This message appears whenever a controller reset or power cycle occurs while Automatic Data Recovery is in progress. No action necessary. 1779-Drive [...]

  • Pagina 70

    3-13 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem Recommended Action 1787-Drive Array Operating in Interim Recovery Mode. Physical drive replacement needed: Drive X None [...]

  • Pagina 71

    3-14 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem Recommended Action 1789-Drive Not Responding, Physical Drive Check cables or replace physical drive X . Select "F1" to continue - drive array will remain disabled. Select "F2" to fail drive(s) that are not respo[...]

  • Pagina 72

    3-15 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem Recommended Action 1793-Drive Array - Array Accelerator Battery Depleted - Data Lost (Error message 1794 also displays.)[...]

  • Pagina 73

    3-16 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem Recommended Action 1798-Drive Array - Array Accelerator Write Error Occurred. Array Accelerator is disabled. None Hard parity error while writing data to posted-writes memory. Enable Array Accelerator. 1799-Drive Array - Drive(s) D[...]

  • Pagina 74

    3-17 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Diagnostics Software Tables 3-2 through 3-20 include all test error codes generated by Compaq products. Each code has a corresponding description and recommended action(s). Your system generates only those codes that [...]

  • Pagina 75

    3-18 Diagnostic Tools 6. Disable the power-on password by using the Password Disable switch on the system board, if you do not have access to the password. 7. Install a loopback plug (Part Number 142054-001), when required by Diagnostics. 8. Run the latest version of Diagnostics. Running Diagnostics There are two ways to access the utilities: ■ F[...]

  • Pagina 76

    3-19 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Primary Processor Test Error Codes The 100 series of Diagnostic error codes identifies failures with processor and system board functions. Table 3-2 Primary Processor Test Error Codes Error Code Description Recommende[...]

  • Pagina 77

    3-20 Diagnostic Tools Memory Test Error Codes The 200 series of Diagnostic error codes identifies failures with the memory subsystem. Table 3-3 Memory Test Error Codes Error Code Description Recommended Action 200-xx Invalid memory configuration. Reinsert memory modules in correct location and retest. 201-xx 202-xx Memory machine ID test failed. Me[...]

  • Pagina 78

    3-21 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Keyboard Test Error Codes The 300 series of Diagnostic error codes identifies failures with keyboard and system board functions. Table 3-4 Keyboard Test Error Codes Error Code Description Recommended Action 301-xx 302[...]

  • Pagina 79

    3-22 Diagnostic Tools Video Display Unit Test Error Codes The 500 series of Diagnostic error codes identifies failures with video or system board functions. Table 3-6 Video Display Unit Test Error Codes Error Code Description Recommended Action 501-xx 502-xx 503-xx 504-xx 505-xx 506-xx 507-xx 508-xx 509-xx 510-xx 511-xx 512-xx 514-xx 516-xx Video c[...]

  • Pagina 80

    3-23 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Diskette Drive Test Error Codes The 600 series of Diagnostic error codes identifies failures with diskette, diskette drive, or system board functions. Table 3-7 Diskette Drive Test Error Codes Error Code Description R[...]

  • Pagina 81

    3-24 Diagnostic Tools Serial Test Error Codes The 1100 series of Diagnostic error codes identifies failures with serial/parallel interface board or system board functions. Table 3-9 Serial Test Error Codes Error Code Description Recommended Action 1101-xx 1109-xx Serial port test failed. Clock register test failed. 1. Check the switch settings on t[...]

  • Pagina 82

    3-25 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Hard Drive Test Error Codes The 1700 series of Diagnostic error codes identifies failures with hard drives, hard drive controller boards, hard drive cabling, and system board functions. If your system uses a drive arr[...]

  • Pagina 83

    3-26 Diagnostic Tools Tape Drive Test Error Codes The 1900 series of Diagnostic error codes identifies failures with tape cartridges, tape drives, tape drive cabling, adapter boards, or the system board assembly. Table 3-12 Tape Drive Test Error Codes Error Code Description Recommended Action 1900-xx 1901-xx 1902-xx 1903-xx 1904-xx 1905-xx 1906-xx [...]

  • Pagina 84

    3-27 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Advanced VGA Board Test Error Codes The 2400 series of Diagnostic error codes identifies failures with video boards, monitors, or the system board assembly. Table 3-13 Advanced VGA Board Test Error Codes Error Code De[...]

  • Pagina 85

    3-28 Diagnostic Tools Advanced VGA Board Test Error Codes Continued Error Code Description Recommended Action 2419-xx 2420-xx 2421-xx 2422-xx 2423-xx 2424-xx 2425-xx 2431-xx 2432-xx 2448-xx 2451-xx 2456-xx ECG/VGC ROM checksum test failed. ECG/VGC attribute test failed. ECG/VGC 640 x 200 graphics mode test failed. ECG/VGC 640 x 350 16-color set tes[...]

  • Pagina 86

    3-29 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide NetFlex-2 Controller Test Error Codes The 6000 series of Diagnostic error codes identifies failures with 32-bit DualSpeed NetFlex-2 and NetFlex-2 Token Ring Controllers. Table 3-14 NetFlex-2 Controller Test Error Code[...]

  • Pagina 87

    3-30 Diagnostic Tools Compaq Network Interface Boards Test Error Codes The 6000 series of Diagnostic error codes identifies failures with 32-bit DualSpeed NetFlex-2/Token Ring Controllers. Table 3-15 Compaq Network Interface Boards Test Error Codes Error Code Description Recommended Action 6000-xx 6001-xx 6002-xx 6014-xx 6016-xx 6028-xx 6029-xx 608[...]

  • Pagina 88

    3-31 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide SCSI Hard Drive Test Error Codes The 6500 series of Diagnostic error codes identifies failures with SCSI hard drives, SCSI hard drive controller boards, SCSI hard drive cabling, and system board functions. If your sys[...]

  • Pagina 89

    3-32 Diagnostic Tools SCSI Tape Drive Test Error Codes The 6700 series of Diagnostic error codes identifies failures with tape cartridges, tape drives, media changers, tape drive cabling, adapter boards, or the system board assembly. Table 3-18 SCSI Tape Drive Test Error Codes Error Code Description Recommended Action 6700-xx 6706-xx 6709-xx 6728-x[...]

  • Pagina 90

    3-33 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Server Manager/R Board Test Error Codes Continued Error Code Description Recommended Action 7000-25 7000-26 7000-27 7000-28 7000-33 7000-34 7000-35 7000-41 7000-42 7000-43 7000-44 7000-45 7000-46 Memory Increment. Mem[...]

  • Pagina 91

    3-34 Diagnostic Tools Pointing Device Interface Test Error Codes The 8600 Diagnostic error codes identifies failures with the pointing device (mouse, trackball, and so on) or the system board assembly. Table 3-20 Pointing Device Interface Test Error Codes Error Code Description Recommended Action 8601-xx Pointing Device Interface test failed. 1. Re[...]

  • Pagina 92

    3-35 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Starting DAAD To start DAAD: 1. Insert the DAAD diskette into drive A. 2. Reboot the system - OR - if you are at the DOS prompt, enter the following: A:DAAD NOTE : To generate a DAAD report without starting the intera[...]

  • Pagina 93

    3-36 Diagnostic Tools DAAD Diagnostic Messages Table 3-21 lists DAAD diagnostic messages in alphabetical order. Table 3-21 DAAD Diagnostic Messages Message Description Recommended Action Accelerator board not detected Array controller did not detect a configured array accelerator board. Install array accelerator board on array controller. If an arr[...]

  • Pagina 94

    3-37 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide DAAD Diagnostic Messages Continued Message Description Recommended Action Accelerator status: Obsolete data sensed at reset During reset initialization obsolete data was found in the cache. This was due to the drives [...]

  • Pagina 95

    3-38 Diagnostic Tools DAAD Diagnostic Messages Continued Message Description Recommended Action Accelerator status: Cache was automatically configured during last controller reset. This can occur when cacheboard is replaced with one of a different size. Cache board was probably replaced with one of a different size. Nothing needs to be done. Normal[...]

  • Pagina 96

    3-39 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide DAAD Diagnostic Messages Continued Message Description Recommended Action Configuration signature is zero DAAD detected that nonvolatile RAM contains a configuration signature that is zero. Old versions of the System [...]

  • Pagina 97

    3-40 Diagnostic Tools DAAD Diagnostic Messages Continued Message Description Recommended Action Controller needs replacing (DAAD Error 104) The Intelligent Array Expansion System firmware is less than version 1.14. Replace the controller as soon as possible. Controller reported POST error. Error Code: x The controller returned an error from its int[...]

  • Pagina 98

    3-41 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide DAAD Diagnostic Messages Continued Message Description Recommended Action Drive (bay) X firmware needs upgrading Firmware on this physical drive is below the latest recommended version. Run the Options ROMPaq Utility [...]

  • Pagina 99

    3-42 Diagnostic Tools DAAD Diagnostic Messages Continued Message Description Recommended Action Drive (bay) X was inadvertently replaced The physical drive was incorrectly replaced after another drive failed. Replace the drive that was incorrectly replaced and replace the original drive that failed. Do not run the System Configuration Utility and t[...]

  • Pagina 100

    3-43 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide DAAD Diagnostic Messages Continued Message Description Recommended Action Logical drive X failed due to cache error This logical drive failed due to a catastrophic cache error. Replace the array accelerator board and [...]

  • Pagina 101

    3-44 Diagnostic Tools DAAD Diagnostic Messages Continued Message Description Recommended Action Logical Drive X status = WRONG DRIVE REPLACED A physical drive in this logical drive has failed. The incorrect drive was replaced. Replace the drive that was incorrectly replaced. Then, replace the original drive that failed with a new drive. Do not run [...]

  • Pagina 102

    3-45 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide DAAD Diagnostic Messages Continued Message Description Recommended Action Threshold violations for drive (bay) X This is a list of the individual thresholds that have been violated for this drive. The drive may need t[...]

  • Pagina 103

    3-46 Diagnostic Tools Integrated Management Log On servers supporting the Integrated Management Display, the Compaq Integrated Management Log (IML) replaces the Critical Error Log and Correctable Memory Logs. It records system events and stores them in an easily viewable form. It marks each event with a time-stamp with one-minute granularity. Event[...]

  • Pagina 104

    3-47 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Viewing the Event List 1. From Compaq Insight Manager, select the appropriate server, then select View Device Data. The selected server displays, with buttons around its perimeter. 2. Select the Recovery button È Int[...]

  • Pagina 105

    3-48 Diagnostic Tools Event List The event list displays the affected components and the associated error messages. Though the same basic information is displayed, the format of the list may differ, depending on how you view it: on the Integrated Management Display, from within Compaq Insight Manager, the IML management utility, or the Compaq Surve[...]

  • Pagina 106

    3-49 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Event Messages Continued Event Type Event Message Processor Correctable Error Threshold exceeded Uncorrectable Error Host Bus Error Processor Correctable error Threshold passed (Slot X, Socket X) Unrecoverable Host Bu[...]

  • Pagina 107

    3-50 Diagnostic Tools Rapid Recovery Services Compaq servers provide rapid recovery services for diagnosing and recovering from errors. These tools are available for local and remote diagnosis and recovery. Rapid recovery means fast identification and resolution of complex faults. The Rapid Recovery Engine and Insight Management Agents notify the s[...]

  • Pagina 108

    3-51 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide The available recovery features are: ■ Software Error Recovery – automatically restarts the server after a software-induced server failure ■ Environmental Recovery – allows the server to restart when temperatu[...]

  • Pagina 109

    3-52 Diagnostic Tools Hardware Requirements To use this level of ASR-2 over a modem, you need the following: ■ Compaq modem or optional Hayes compatible modem ■ System Configuration Utility and Diagnostics Utility installed on the system partition of the hard drive ■ ASR-2 configured to load Compaq Utilities after restart You can also run Com[...]

  • Pagina 110

    3-53 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Compaq Integrated Remote Console The standard Compaq Integrated Remote Console performs a wide range of configuration activities. Some of the console’s features include: ■ Accessible using ANSI terminal ■ Operat[...]

  • Pagina 111

    3-54 Diagnostic Tools The following ASR-2 flow chart shows you the sequence of events after a hardware or software error occurs : Hardware/Software error occurs | Error records in the Critical Error Log, or the Integrated Management Log, depending on your server configuration. | Operating System halts normal operation | ASR Timer expires | Server i[...]

  • Pagina 112

    3-55 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Booting into Compaq Utilities When you enable ASR-2 to start into Compaq Utilities and a critical error occurs, the operating-system-specific Health Driver logs the error information in the Critical Error Log or the I[...]

  • Pagina 113

    3-56 Diagnostic Tools Table 3-23 Compaq System Configuration Utility Pager Settings for Booting into Compaq Utilities Pager Data Setting Description Pager status Enabled Indicates if the pager feature is enabled or disabled. Pager dial string ATDT 555-5555 Indicates the pager dial string and delay before the pager message. Pagers typically use one [...]

  • Pagina 114

    3-57 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Compaq System Configuration Utility Pager Settings for Booting into Compaq Utilities Continued Pager Data Setting Description Dial-out status Enabled Allows ASR-2 to dial out to a remote workstation. If you selected t[...]

  • Pagina 115

    3-58 Diagnostic Tools Compaq System Configuration Utility Pager Settings for Booting into Compaq Utilities Continued Pager Data Setting Description Network IP address N/A Enter the IP address for this server in standard dot notation. NOTE: This is not used if you select Custom for Network controller. You must enter your IP address in the NET. CFG f[...]

  • Pagina 116

    3-59 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide ■ Network controller Compaq ■ Network host name CPQHOU ■ Network card slot Slot # ■ Network frame type ETHERNET_II ■ Network IP address xxx.xxx.xxx.xxx ■ Network IP net mask xxx.xxx.xxx.xxx ■ Network IP [...]

  • Pagina 117

    3-60 Diagnostic Tools Critical Error Log The Critical Error Log records memory errors, as well as catastrophic hardware and software errors that cause the system to fail. This information helps you quickly identify and correct the problem, thus minimizing downtime. You can view the Critical Error Log through the Compaq Insight Manager. The Diagnost[...]

  • Pagina 118

    3-61 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Critical Error Log Messages Continued Message Description NMI - PCI Bus Parity Error A parity error was detected on the PCI bus. NMI - Expansion Board Error A board on the expansion bus indicated an error condition, r[...]

  • Pagina 119

    3-62 Diagnostic Tools Revision History Table Some errors can be resolved by reviewing changes to the server configuration. The server has an Automatic Revision Tracking (ART) feature that helps you review recent changes to the server configuration. One ART feature is the Revision History Table, which contains the hardware version number of the syst[...]

  • Pagina 120

    3-63 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Storage Fault Recovery Tracking This feature tracks over 12 failure-indication parameters, such as time-outs, spin-up, and self-test errors of SCSI drives. You can use these parameters to pinpoint failed storage subsy[...]

  • Pagina 121

    3-64 Diagnostic Tools Remote Service Features Compaq servers have the following management features that you can access via modem or network: Table 3-26 Compaq Servers Remote Management Features Feature Description Service Session Provides remote access to all the utilities on the system partition, including Diagnostics utilities, Inspect, ROMPaq, [...]

  • Pagina 122

    3-65 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide ROMPaq Using flash ROM in Compaq servers allows the firmware (BIOS) to be upgraded with system or option ROMPaq utilities. To upgrade the ROM: ■ Run the ROMPaq utility from the system partition, or ■ Insert a ROMP[...]

  • Pagina 123

    3-66 Diagnostic Tools ■ Asset Management - Exports asset information from the Compaq Insight Manager database to leading database and spreadsheet applications. ■ Remote Management - Manages in-band or out-of-band devices, online or offline, from any location. ■ Reporting - Using Automatic Data Collection, gathers historic performance informat[...]

  • Pagina 124

    4-1 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Chapter 4 Connectors, Switches, Jumpers, and LEDs This chapter provides connector, switch, jumper, and LED information for Compaq ProLiant 3000 Servers . Connectors This section contains information concerning all conn[...]

  • Pagina 125

    4-2 Connectors, Switches, Jumpers, and LEDs System I/O Board Connectors Figure 4-2 shows the system I/O board connectors for ProLiant 3000 Servers. Table 4-2 gives the corresponding connector descriptions. 1 7 9 12 13 14 15 16 17 6 5 2 3 4 18 19 20 21 22 23 11 8 10 Figure 4-2. System I/O board connectors Table 4-2 System I/O Board Connectors Refere[...]

  • Pagina 126

    4-3 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Switches This section contains information concerning all internal switches on ProLiant 3000 Servers. Configuration Switch Settings Figure 4-3 shows the system I/O board configuration switch location and default settin[...]

  • Pagina 127

    4-4 Connectors, Switches, Jumpers, and LEDs Processor Switch Settings The following figures and table show the location and default settings of the processor switch for ProLiant 3000 Servers. There is a different default setting for each processor switch including the 350 MHz, 400 MHz, 450 MHz, and 500 Mhz processors. 1 on 2 350 MHz 3456 Figure 4-4[...]

  • Pagina 128

    4-5 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide 1 on 2 450 MHz 3456 Figure 4-6. 450 MHz processor switch location and default settings 1 on 2 500 MHz 3456 Figure 4-7. 500 MHz processor switch location and default setting Table 4-4 Processor Switch Settings Processor[...]

  • Pagina 129

    4-6 Connectors, Switches, Jumpers, and LEDs Jumpers The external battery jumper for ProLiant 3000 Servers is located on the system I/O board. Figure 4-8 shows the configuration when using an internal battery 1 or an external battery 2 . 1 INT . JUMPER 2 EXT . JUMPER Figure 4-8. Battery jumper location and default settings[...]

  • Pagina 130

    4-7 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide LEDs This section contains information concerning all service LEDs located on ProLiant 3000 Servers. Hot-Plug Power Supply LEDs Each power supply has a status LED and an AC power LED. Figure 4-9 shows the power supply [...]

  • Pagina 131

    4-8 Connectors, Switches, Jumpers, and LEDs Power Switch LED The power switch LED is located on the front of the server beneath the power switch and illuminates when the power is on. Figure 4-10 shows the location of the power switch LED for ProLiant 3000 Servers. Figure 4-10. Power switch LED CD-ROM Drive LED The CD-ROM drive LED is located on the[...]

  • Pagina 132

    4-9 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Diskette Drive The diskette drive LED is located on the front of the diskette drive, near the bottom left of the diskette drive slot. The LED illuminates green when the diskette drive is in operation. Figure 4-12 shows[...]

  • Pagina 133

    4-10 Connectors, Switches, Jumpers, and LEDs Hot-Plug Hard Drive LEDs LEDs on each hot-plug hard drive show the operational status of the hard drive. Figure 4-13, Table 4-6, and Figure 4-14 show the hot-plug hard drive LED locations, functions, and replacement conditions for ProLiant 3000 Servers. CAUTION: Replace a hard drive only when the drive L[...]

  • Pagina 134

    4-11 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Drive Indicators Online OFF Drive Access Drive Failure OK to remove drive if not part of fault-tolerant configuration DO NOT remo ve drive DO NOT remo ve drive Figure 4-14. Hot-Plug hard drive LEDs and replacement con[...]

  • Pagina 135

    5-1 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Chapter 5 Physical and Operating Specifications This section provides operating and performance specifications for Compaq ProLiant 3000 Servers and optional hardware. ■ System Unit ■ Power Supply ■ Synchronous DR[...]

  • Pagina 136

    5-2 Physical and Operating Specifications System Unit Table 5-1 System Unit Specifications U.S. Metric Dimensions Height 20.5 in 52.1 cm Depth 24.5 in 62.2 cm Width 12.7 in 32.3 cm Weight (Model 1, U.S.) 75 lbs 34 kg Input Requirements Low range High range Rated Input Voltage 100 to 120 V 200 to 240 V Rated Input Frequency 50 to 60 Hz 50 to 60 Hz R[...]

  • Pagina 137

    5-3 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Power Supply Table 5-2 Power Supply Specifications U.S. Metric Input Specifications Nominal Line Voltage 100 to 120 VAC 200 to 240 VAC Range Input Line 90 to 132 VAC 180 to 270 VAC Frequency Range 47 to 63 Hz 47 to 63 [...]

  • Pagina 138

    5-4 Physical and Operating Specifications SDRAM Dual Inline Memory Modules CAUTION: Use only SDRAM DIMMs of the same size, speed, and manufacturer. SDRAM DIMMs from other sources may adversely affect data integrity. Power-On Self-Test (POST) will warn of non-supported SDRAM DIMMs. Table 5-3 SDRAM DIMM Specifications Size 16, 32, 64, 128, 256, or 51[...]

  • Pagina 139

    5-5 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide 1.44-MB Diskette Drive Table 5-4 1.44-MB Diskette Drive Specifications U.S. Metric Size 3.5 in LED Indicators (front panel) Green Read/Write Capacity per Diskette (high/low density) 1.44 MB/720 KB Drives Supported One [...]

  • Pagina 140

    5-6 Physical and Operating Specifications IDE CD-ROM Drive Table 5-5 IDE CD-ROM Drive Specifications U.S. Metric Dimensions Height 1.7 in 42.9 mm Weight 5.9 in 150.1 mm Depth 8.1 in 208.0 mm Weight 2.1 lb 950 g Capacity Mode 1, 12 cm 540 MB Mode 2, 12 cm 630 MB Sustained 150 KB/s Access Times Full Stroke <200 ms Random <100 ms Bus Rate 4.0 MB[...]

  • Pagina 141

    5-7 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide IDE CD-ROM Drive Specifications Continued U.S. Metric Laser Parameters Type Semiconductor laser GaAlAs Wave Length 780 +/- 25 nm Divergence Angle 53.5 +/- 1.5 degrees Output Power 0.14 mW Audio Interface Line Out Conne[...]

  • Pagina 142

    5-8 Physical and Operating Specifications Smart Array 3200 Controller Table 5-6 Smart Array 3200 Controller Specifications U.S. Metric Dimensions Height 3.9 in 9.9 cm Length 13.75 in 34.9 cm Thickness (including Array Accelerator) 0.60 in 1.5 cm Total Weight (including Array Accelerator) N/A N/A Temperature Range Operating 50 ° to 95 ° F1 0 ° to[...]

  • Pagina 143

    5-9 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Hot-Plug Wide-Ultra Hard Drives Table 5-7 Hot-Plug Wide-Ultra Hard Drive Specifications 4.3 GB 4.3 GB 9.1 GB 9.1 GB 18.2 GB Rotational Speed (rpm) 7,200 10,000 7,200 10,000 7,200 Logical Capacity (MB) 4293.6 4293.6 910[...]

  • Pagina 144

    5-10 Physical and Operating Specifications Hot-Plug Wide-Ultra2 Hard Drives Table 5-8 Hot-Plug Wide-Ultra2 Hard Drive Specifications 4.3 GB 4.3 GB 9.1 GB 9.1 GB Rotational Speed (rpm) 7,200 10,000 7,200 10,000 Logical Capacity (MB) 4293.6 4293.6 9100 9100 Height Inches 1.0 1.0 1.0 1.0 Centimeters 2.5 2.5 2.5 2.5 Size Inches 3.5 3.5 3.5 3.5 Centimet[...]

  • Pagina 145

    5-11 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Non-Hot-Plug Wide Ultra2 Hard Drives Table 5-9 Non-Hot-Plug Wide-Ultra2 Hard Drive Specifications 4.3 GB 4.3 GB 9.1 GB 9.1 GB 18.2 GB Rotational Speed (rpm) 7,200 10,000 7,200 10,000 10,000 Logical Capacity (MB) 4293.[...]

  • Pagina 146

    5-12 Physical and Operating Specifications Hot-Plug Wide-Ultra SCSI-3 Hard Drives Table 5-10 Hot-Plug Wide-Ultra SCSI-3 Hard Drive Specifications 4.3 GB 4.3 GB 9.1 GB 9.1 GB 18.2 GB 18.2 GB Rotational Speed (rpm) 7200 10,000 7,200 10,000 10,000 10,000 Logical Capacity (MB) 4293.6 4293.6 9100 9100 18209.8 18209.8 Height Inches 1.0 1.0 1.0 1.0 1.6 1.[...]

  • Pagina 147

    Index - 1 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Index A AC power cord connector location 4-1 access panels side part number 1-3 removing 2-12 removing, illustrated 2-12 replacing 2-12 top part number 1-3 removing 2-10 removing, illustrated 2-10 replacing 2-10 [...]

  • Pagina 148

    I nde x -2 cables Continued SCSI removable media, folding and routing 2-29 Wide SCSI w/Terminator, part number 1-4 card guide, part number 1-4 carton, part number 1-4 caster mounting support part number 1-3 removing 2-6 removing, illustrated 2-6 replacing 2-6 casters part number 1-3 removing 2-5 removing, illustrated 2-5 replacing 2-5 cautions airf[...]

  • Pagina 149

    Index -3 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide DAAD (Drive Array Advanced Diagnostics) Continued diagnostic messages 3-36 starting 3-35 default configuration messages 3-2 settings, description 3-2 Diagnose Drive Array utility, accessing 3-17 diagnostics access[...]

  • Pagina 150

    I nde x -4 E electrostatic discharge, preventing 2-1 Enabler board Duplex, removing 2-21 Duplex, replacing 2-21 Simplex, removing 2-21 Simplex, replacing 2-21 environmental recovery 3-51 error 101, description 3-4 101-XX, description 3-19 102, description 3-4 103-XX, description 3-19 104, description 3-4 104-XX, description 3-19 105-XX, description[...]

  • Pagina 151

    Index -5 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide error Continued 1781, description 3-12 1782, description 3-12 1784, description 3-12 1785, description 3-12 1786, description 3-12 1787, description 3-13 1788, description 3-13 1789, description 3-14 179, descript[...]

  • Pagina 152

    I nde x -6 error Continued 505-XX, description 3-22 506-XX, description 3-22 507-XX, description 3-22 508-XX, description 3-22 509-XX, description 3-22 510-XX, description 3-22 511-XX, description 3-22 512-XX, description 3-22 514-XX, description 3-22 516-XX, description 3-22 6000-XX, description 3-29, 3-30 6001-XX, description 3-29, 3-30 6002-XX, [...]

  • Pagina 153

    Index -7 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide error Continued Accelerator status Cache was automatically configured during last controller reset. This can occur when cacheboard is replaced with one of a different size., description 3-38 Data in the cache was [...]

  • Pagina 154

    I nde x -8 error Continued Drive Monitoring features are unobtainable, description 3-40 Drive Monitoring is NOT enabled for drive bay X, description 3-40 Drive time-out occurred on physical drive bay X, description 3-40 Drive X indicates position Y, description 3-41 Duplicate write memory error, description 3-42 Error Detected On Boot Up 3-60 Error[...]

  • Pagina 155

    Index -9 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide fans baffle, part number 1-4 front part number 1-3 removing 2-16 removing, illustrated 2-16 replacing 2-16 location, illustrated 2-15 rear part number 1-3 removing 2-18 removing, illustrated 2-18 replacing 2-18 re[...]

  • Pagina 156

    I nde x -10 illustrations Continued caster mounting support, removing 2-6 casters, removing 2-5 CD-ROM drive cable folding and routing 2-28 removing 2-26 chassis components, exploded view 1-1 DIMMs removing 2-32 diskette drive cable folding and routing 2-28 removing 2-27 diskette drive LED 4-9 door, front bezel, removing 2-7 drive bay locations 2-1[...]

  • Pagina 157

    Index -11 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide IP/IPX setting after enabling ASR 3-58 using network features 3-52 J jumper external battery 4-6 external battery, illustrated 4-6 K keyboard part number 1-4 test error codes 3-21 L laser parameters, CD-ROM drive[...]

  • Pagina 158

    I nde x -12 panels Continued side access part number 1-3 removing 2-12 removing, illustrated 2-12 replacing 2-12 top access part number 1-3 removing 2-10 removing, illustrated 2-10 replacing 2-10 U-channel access part number 1-3 removing 2-11 removing, illustrated 2-11 replacing 2-11 parallel printer, test error codes 3-21 part numbers access panel[...]

  • Pagina 159

    Index -13 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide power backplane board Continued removing, illustrated 2-40 replacing 2-40 power cord, connector location 4-1 power module part number 1-3 removing 2-36 removing, illustrated 2-36 replacing 2-36 power supply blank[...]

  • Pagina 160

    I nde x -14 ROMPaq Firmware Upgrade Utility, accessing 3-2, 3-3 ROM upgrade procedure 3-65 S SCSI cable folding and routing, illustrated 2-29 Duplex Hot-Plug Drive Cage, part number 1-5 Simplex Hot-Plug drive cage, part number 1-3 tape drive, test error codes 3-32 SCSI hard drive, test error codes 3-31 SDRAM See DIMMs security, ASR-2 3-59 serial, t[...]

  • Pagina 161

    Index -15 Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide systems reference library, SmartStart and Support Software CD-ROM 3-50 T tape drive, removing 2-26 tape drive, test error codes 3-26, 3-32 technical support Compaq website address ix telephone numbers ix telephon[...]

  • Pagina 162

    I nde x -16 W warnings battery handling and disposal 2-43 CD-ROM drive 2-2 component level repairs viii definition vii electrical shock vii, viii, 2-2, 2-38 equipment damage viii, 2-2, 2-3, 2-38 grounding viii, 2-4 hazardous energy levels vii, viii hot surfaces 2-2, 2-4, 2-10, 2-12 improper repairs vii installing options 2-3 laser 2-2 network inter[...]