Un buon manuale d’uso

Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Barco DOC-3200-2. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Barco DOC-3200-2 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.

Che cosa è il manuale d’uso?

La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Barco DOC-3200-2 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.

Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.

Quindi cosa dovrebbe contenere il manuale perfetto?

Innanzitutto, il manuale d’uso Barco DOC-3200-2 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Barco DOC-3200-2
- nome del fabbricante e anno di fabbricazione Barco DOC-3200-2
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Barco DOC-3200-2
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti

Perché non leggiamo i manuali d’uso?

Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Barco DOC-3200-2 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Barco DOC-3200-2 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Barco in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Barco DOC-3200-2, come nel caso della versione cartacea.

Perché leggere il manuale d’uso?

Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Barco DOC-3200-2, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.

Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Barco DOC-3200-2. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.

Sommario del manuale d’uso

  • Pagina 1

    DOC-3200-2 User's Manual[...]

  • Pagina 2

    DOC-3200-2, Current Version Title: H ERMES DXD – User’s Manual ID-no.: DOC-3200-2 Date: 2003-09 main issue update chapter 1 new chapter 2 new chapter 3 new chapter 4 new chapter 5 new chapter 6 new chapter 7 new new: The corresponding chapters are new or completely revised. corr.: Passages of the corresponding chapter were corrected; see modifi[...]

  • Pagina 3

    Trademarks Brand and product names mentioned in this manual may be trademarks, registered trademarks or copyrights of their respective holders. All brand and product names mentioned in this manual serve as comments or examples and are not to be understood as advertising for the products or their manufacturers. Copyright © 1999 - 2003 by Barco Cont[...]

  • Pagina 4

    Revision sheet To:  Barco Control Rooms GmbH An der Rossweid 5, D-76229 Karlsruhe Phone: +49-721-6201-0, Fax: +49-721-6201-298 E-mail: docu.de.bcd@barco.com Web: www.barcocontrolrooms.de  BarcoProjection Noordlaan5, B-8520 Kuurne, Belgium Phone: (32) (56) 36-8211, Fax: (32) (56) 36-8251 E-mail: sales.bcd@barco.com , Web: www.barcocontrolrooms[...]

  • Pagina 5

    Table of Contents 1 Preliminary Remarks.......................................................................................................... .......... 1-1 1.1 How this manual is organized ............................................................................................. 1- 2 1.2 Styles and Symbols ..................................[...]

  • Pagina 6

    5 Controlling Hermes DXD ....................................................................................................... ..... 5-1 5.1 Valid Commands for Hermes DXD .................................................................................... 5-2 5.2 Request commands ...................................................................[...]

  • Pagina 7

    1 Prelim i n a ry Remarks This User’s Manual describes design, function and operation of H ERMES DXD of Barco. H ERMES DXD is a multiplexer to connect each of two digital projection units alternatively to two graphical controllers. Barco's product range of digital projection units comprises projection mod- ules of the O VER V IEW D series an[...]

  • Pagina 8

    1.1 How th i s ma nual is organized This manual is divided into seven chapters: Preliminary Remarks explains the structure of the manual itself and the used typographic styles and symbols. Safety in- formation is provided concerning the operation of systems from Barco. Summary provides a summary of the system components and characteristics. First s[...]

  • Pagina 9

    1.2 Styles a n d Symbols The typographic styles and the symbols used in this document have the following meaning: Arial bold Labels, menus and buttons are printed in the Arial bold font. Condensed Links to both other chapters of this manual and to sites in the Internet are printed condensed . In the on-line version of this manual all hyperlinks app[...]

  • Pagina 10

    1.3 Safety I n for mation This section describes safety precautions which must be observed when installing a product from BARCO. H ERMES DXD is built in accordance with the requirements of the international safety standard IEC950, UL1950 and CSA C22.2 No. 950, which are the safety standards of information technol- ogy equipment including electrical[...]

  • Pagina 11

     Do not allow anything to rest on the power cord. Do not locate this product where persons will walk on the cord.  To disconnect the cord, pull it out by the plug. Never pull the cord itself.  If an extension cord is used with this product, make sure that the total of the ampere ratings on the products plugged into the extension cord does [...]

  • Pagina 12

    On Servicing Do not attempt to service this device yourself, as opening or removing covers may expose you to dangerous voltage potential and risk of electric shock! Refer all service to a qualified BARCO service center. Adjust only those controls that are covered by the operating instructions since improper adjust- ment of the other controls may re[...]

  • Pagina 13

    2 Summ a r y This chapter gives an overview of the H ERMES DXD.[...]

  • Pagina 14

    2.1 Conne c t i ng the graphical controller and the projection cubes H ERMES DXD is equipped with two digital input connectors ( Digital In 1, Digital In 2 ) and two digital output connectors ( Digital Out 1, Digital Out 2 ). The output connectors can be routed to any input connector, resulting in the following fields of applications: Hermes DXD as[...]

  • Pagina 15

    2.2 Assign i n g i nputs to outputs H ERMES DXD is operated by means of remote control, and the inputs are routed to the output via the respective command, cf. 5.3 Switching commands . The following schematics show the multiple possibilities for assigning an input to an output. For a clear arrangement, the connections which can be established in pa[...]

  • Pagina 16

    3 Gettin g s tarted This chapter describes the control elements and interfaces of H ERMES DXD as well as the cabling.[...]

  • Pagina 17

    3.1 Examin i n g Figure 3-1 Hermes DXD 3.1.1 The Fro n t Pa nel The front panel of your H ERMES DXD looks like this or similar: 1 POWER DIGITAL OUT 2 DIGITAL OUT 1 DIGITAL IN 2 DIGITAL IN 1 REMOTE OUT REMOTE IN 23 4 56 7 8 9 1 0 1 1 Figure 3-2 Front Panel of Hermes DXD 1 REMOTE IN 2 REMOTE OUT 3 LED: DIGITAL IN 1 4 DIGITAL IN 1 5 LED: DIGITAL IN 2 [...]

  • Pagina 18

    LEDs allocated to the inputs: If they are off, there is no signal present. If there is a sync signal present, the LED is on: Green stands for (signal present on) input (channel) 1 Orange stands for (signal present on) input (channel) 2 LEDs allocated to the outputs: The color of the LED indicates which input (channel) is displayed: In case it is gr[...]

  • Pagina 19

    3.1.2 The Bac k Panel The back panel of your H ERMES DXD looks like this or similar: A BC A Main Switch B AC In C AC Out Figure 3-3 The Main Switch [A] is for switching H ERMES DXD on and off. If the 0 is visible on top of the switch, the device is switched off, and it can be switched on by pressing the switch. The AC In socket [B] is for connectin[...]

  • Pagina 20

    3.2 Native d e v ice settings (default settings) Hermes DXD has auto switch capabilities: in case there is no signal present at the input routed to an output, the output may switch automatically to the other input. Per default, this auto switch functionality is enabled. If desired, it can be deactivated, cf. Enabling/Disabling auto switch Having tw[...]

  • Pagina 21

    3.4 Cabling This block diagram gives an overview about the cabling of H ERMES DXD Figure 3-4 cabling Hermes DXD The cabling must be done before switching on H ERMES DXD or any other system components! Signal cables are available in different types (fibre or copper), different interfaces (PanelLink-to-DVI, DVI-to-PanelLink, DVI-to-DVI) and different[...]

  • Pagina 22

    3.4.2 Digital I n p ut and Output H ERMES DXD has DVI interfaces. Depending on the type of graphical card and/or the type of projection module, the following kind of cables are required: DVI-to-DVI, DVI-to-PanelLink, PanelLink-to-DVI. The DVI-DVI cable is available as copper cable (length up to 10m) and fibre cable (length up to 100m). The DVI-to-P[...]

  • Pagina 23

    3.5 Operat i n g Hermes DXD After the cabling is done, you can switch on your system. In order to provide the graphic cards with the correct timing, it is mandatory that H ERMES DXD is switched on before booting the controller! The projection engines can be switched on or off: the timing information is received via the data cable as soon as the con[...]

  • Pagina 24

    4 Remo t e Control The remote control is a system for scanning and controlling single devices of Barco Display Wall. As a certain class of devices H ERMES DXD can be scanned from a central computer. By means of remote control the respective input can be switched to a desired output. This chapter describes the basics of remote control as cabling, pr[...]

  • Pagina 25

    4.1 Cabling A remote control system consists of three different components:  remote control master ( RCM )  remote control slave ( RCS )  remote control connection The RCM is the central computer which controls the slave devices RCS . All control messages are gener- ated by the RCM , addressed to a certain RCS device and sent on. Incorrect[...]

  • Pagina 26

    4.1.2 Cabling o f Hermes DXD (number of devices > 20) If there are more than 20 devices a distribution panel has to be used. Then the cabling looks like this: Figure 4-3 remote control cabling by use of a distriubtion panel Remote control cabling is available in various length and with adapters for connecting to different de- vices. See section [...]

  • Pagina 27

    4.2.3 Structu r e of Messages The messages consists out of a RCS -independent and a RCS -dependent layer. The RCS -independent parts are interpreted the same by all types of devices. The RCS -dependent parts contain specific com- mands for a certain type of RCM : the message body. A message has the following structure: <STX> <TYPE> <[...]

  • Pagina 28

    4.2.5 Types o f RCS Classes e O VER V IEW - M L r MULTI M EDIA -T ERMINAL M MT-X, M MT-NT, E OS s MULTI M EDIA -T ERMINAL M MT-S m AVC-B OX , D IGITAL S WITCHBOX , A NALOG I NPUT B OX , H ERMES D2D, H ERMES V2A, H ERMES DXD, H ERMES VXA Table 4-4 4.3 How to c a lculate the checksum The checksum is being evaluated from the recipient to make sure tha[...]

  • Pagina 29

    4.4 The sta t u s register The status register stores information about which input is provided with a signal, which input is switched to which output, and if autoswitch modus is enabled or disabled. The following lists the bits of the Status Register, the M ost S ignificant B it is the most left bit, the L east S ignificant B it is the most right [...]

  • Pagina 30

    5 Contr o l l in g Hermes DXD This chapter describes the commands to control H ERMES DXD, the commands and the an- swers/acknowledge.[...]

  • Pagina 31

    5.1 Valid C o m m ands for Hermes DXD command description t selects input from first graphical controller as signal for Digital Out 1 a selects input from second graphical controller as signal for Digital Out 1 s selects input from first graphical controller as signal for Digital Out 2 b selects input from second graphical controller as signal for [...]

  • Pagina 32

    5.2 Reques t com mands Request commands can be sent from the RCS to the RCM or vice versa. The answer of a request com- mand does not include the status information. Command "R": Calling for Address Description: Request for an address. A RCS that is not provided with an address will send requests for an address at regular intervals. This [...]

  • Pagina 33

    Command "I": Calling for Information Description: This request is about the identity number of the device and the version of the firmware. Example: The message sent from the RCM to the RCS1 about the identity number is: Message <STX> <TYPE> <ADDRH> <ADDRL> <Body> <STATH> <STATL <CHKH> <CHKL&[...]

  • Pagina 34

    Command "a": interconnection digital input 2 to digital output 1 Description: Via the command a the RCM tells the RCS of class m to switch the signal of the second input ( DIGITAL IN 2 ) to the first digital output DIGITAL OUT 1 . The RCS executes the command and sends the acknowledge which informs via the status register about the auto s[...]

  • Pagina 35

    Command "t": interconnection digital input 1 to digital output 1 Description: Via this command the RCM tells the RCS of class m to switch the signal of the first input ( DIGITAL IN 1 ) to the first digital output DIGITAL OUT 1 . The RCS executes the command and sends the acknowledge which informs via the status register about the auto swi[...]

  • Pagina 36

    Command "b": interconnection digital input 2 to digital output 2 Description: Via this command the RCM tells the RCS of class m to switch the signal of the second in- put ( DIGITAL IN 2 ) to the second digital output DIGITAL OUT 2 . The RCS executes the command and sends the acknowledge which informs via the status register about the auto[...]

  • Pagina 37

    Command "s": interconnection digital input 1 to digital output 2 Description: Via this command the RCM tells the RCS of class m to switch the signal of the first input ( DIGITAL IN 1 ) to the second digital output DIGITAL OUT 2 . The RCS executes the command and sends the acknowledge which informs via the status register about the auto sw[...]

  • Pagina 38

    5.4 Enablin g / D isa bling auto switch The auto switch functionality allows H ERMES DXD to automatically connect an output to the other input if there is no longer a sync signal on the input previous connected to this output. This functionality pro- vides redundancy (inspite of a crash, there will be signal displayed on the projection modules), bu[...]

  • Pagina 39

    Command “k”: Disabling auto switch Description: Via this command the RCM tells the RCS of class m to disable auto switch The RCS executes the command and sends the acknowledge which informs via the status register about the auto switch status. Example: The command k is sent to the second RCS : Message <STX> <TYPE> <ADDRH> <[...]

  • Pagina 40

    5.4.1 Comma n d s referring to settings The connections of H ERMES DXD (which input is connected to which output) as well as the status of the auto switch functionality make up the settings of H ERMES DXD and can be saved and restored on the device. The native configuration (factory configuration) of H ERMES DXD is saved in the default settings . I[...]

  • Pagina 41

    Command “i”: save user settings Description: Via this command the RCM tells the RCS of class m to save the current configuration as user settings. These are the features to be saved: connection of DIGITAL OUTPUT 1 connection of DIGITAL OUTPUT 2 status of auto switch The RCS executes the command and sends the acknowledge which informs via the st[...]

  • Pagina 42

    Let's assume that the following routing is saved as user settings: DIGITAL OUTPUT 1 is connected to DIGITAL INPUT 2 DIGITAL OUTPUT 2 is connected to DIGITAL INPUT 1 Autoswitch enabled Let's further assume that there is a sync signal on DIGITAL INPUT 1 , and no sync signal on DIGITAL INPUT 2 . Therefore the actual configuration differs fro[...]

  • Pagina 43

    5.5 Readin g t he status register Although the information about the status register is sent back by the RCS as part of the acknowledge, it might be useful to ask it directly. Command “o”: read status register Description: Via this command the RCM tells the RCS of class m to read the status register. The RCS executes the command and sends the a[...]

  • Pagina 44

    5.6 Readin g t he product identification The entire product information "finger print" is saved in an EEPROM and can be read and evaluated. This information is a very useful diagnostic help for the Barco support technician. Command “v”: read product information Description: After having received this command, the RCS will send the des[...]

  • Pagina 45

    5.7 Error m e s s ages Three different kind of errors might occur:  The body is an invalid command  The checksum is not correct  The device cannot be addressed (it might be switched off…) The information sent back to the RCM about these errors does not include the status register Error Protocol "EP" Description: Via this answer[...]

  • Pagina 46

    Original message is sent back to the RCM Description: Via this answer the RCM recognizes that the desired RCS cannot be addressed (might be it has been switched off…) Example: The RCM has sent the following command: Message <STX> <TYPE> <ADDRH> <ADDRL> <Body> <STATH> <STATL <CHKH> <CHKL> <ETX&[...]

  • Pagina 47

    6 Broad c a s t addressing mode This chapter describes how all Remote Control Slaves of a class are addressed simultaneously.[...]

  • Pagina 48

    6.1 Structu r e of message The messages consists out of a RCS -independent and a RCS -dependent layer. The RCS -independent parts are interpreted the same by all types of devices. The RCS -dependent parts contain specific com- mands for a certain type of RCM : the message body. A message has the following structure: <STX> <TYPE> <ADD[...]

  • Pagina 49

    6.3 Comm a n ds for broadcast addressing In principle, all commands can be sent in broadcast addressing mode, however, some of the valid com- mands are not very useful to be sent to all of the RCS simultaneously. The following table lists the commands for reasonable broadcasting addressing. For H ERMES DXD it's the switching commands which are[...]

  • Pagina 50

    7 Techn i c a l Data[...]

  • Pagina 51

    7.1 Genera l D ata 7.1.1 Dimens i o ns characteristic specification weight 2980g W×H×D 378mm × 61mm × 304mm Table 7-1 7.1.2 Power S u p pl y characteristic specification AC power supply 100-240V mains frequency 50/60Hz power consumption max. 10W inrush current 110V 230V < 18A < 36A outlet Same as input Table 7-2[...]

  • Pagina 52

    7.1.3 Operati n g Conditions characteristic specification operating temperature 0 .. 50 degrees Celsius (32 .. 122 °F) humidity 8 .. 80% non condensing Table 7-3[...]

  • Pagina 53

    7.2 Interfac e s 7.2.1 Remote I n 1 6 9 5 1 - 6 - 2 TXD 7 - 3 RXD 8 - 4 - 9 - 5 GND Table 7-4 7.2.2 Remote O ut 1 6 9 5 1 - 6 - 2 TXD 7 - 3 RXD 8 - 4 - 9 - 5 GND Table 7-5[...]

  • Pagina 54

    7.2.3 Digital I n Pin Signal Assignment Pin Signal Assignment 1 TMDS Data 2- 13 - 2 TMDS Data 2+ 14 - 3 TMDS Data 2 Shield 15 Ground (+5, Analog /V Sync) 4 - 16 - 5 - 17 TMDS Data 0- 6 DDC Clock 18 TMDS Data 0+ 7 DDC Data 19 TMDS Data 0 Shield 8 - 20 - 9 TMDS Data 1- 21 - 10 TMDS Data 1+ 22 TMDS Clock Shield 11 TMDS Data 1 Shield 23 TMDS Clock + 12[...]

  • Pagina 55

    7.3 Parts L i s t 7.3.1 Hermes D XD order no. designation RSAVC31870 H ERMES DXD RSCBL32060 DVI-DVI cable, copper, 2m RSCBL32062 DVI-DVI cable, copper, 5m RSCBL32063 DVI-DVI cable, copper, 10m RSCBL32040 DVI-DVI cable, fibre, 10m RSCBL32041 DVI-DVI cable, fibre, 20m RSCBL32042 DVI-DVI cable, fibre, 50m RSCBL32043 DVI-DVI cable, fibre, 100m RSCBL320[...]

  • Pagina 56

    7.4 Addres s 4 Barco Control Rooms GmbH An der Rossweid 5 • D-76229 Karlsruhe • Germany Phone (49) (721) 6201-0 • Fax (49) (721) 6201-298 E-mail info.de.bcd@barco.com Web www.barcocontrolrooms.de 4 BarcoProjection Noordlaan 5 • B-8520 Kuurne • Belgium Phone (32) (56) 36-8211 • Fax (32) (56) 36-8251 E-mail sales.bcd@barco.com • Web www[...]