Xantrex Technology SW Plus 4048 manuel d'utilisation

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344

Aller à la page of

Un bon manuel d’utilisation

Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Xantrex Technology SW Plus 4048. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Xantrex Technology SW Plus 4048 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.

Qu'est ce que le manuel d’utilisation?

Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Xantrex Technology SW Plus 4048 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.

Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.

Donc, ce qui devrait contenir le manuel parfait?

Tout d'abord, le manuel d’utilisation Xantrex Technology SW Plus 4048 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Xantrex Technology SW Plus 4048
- nom du fabricant et année de fabrication Xantrex Technology SW Plus 4048
- instructions d'utilisation, de réglage et d’entretien de l'équipement Xantrex Technology SW Plus 4048
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes

Pourquoi nous ne lisons pas les manuels d’utilisation?

Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Xantrex Technology SW Plus 4048 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Xantrex Technology SW Plus 4048 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Xantrex Technology en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Xantrex Technology SW Plus 4048, comme c’est le cas pour la version papier.

Pourquoi lire le manuel d’utilisation?

Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Xantrex Technology SW Plus 4048, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.

Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Xantrex Technology SW Plus 4048. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.

Table des matières du manuel d’utilisation

  • Page 1

    Sine W ave Plus Inverter/Charg er Owner’ s Manual SW Plus 2524 SW Plus 2548 SW Plus 4024 SW Plus 4[...]

  • Page 2

    [...]

  • Page 3

    Sine Wave Pl us Inverter/Charger Owner’s Manual[...]

  • Page 4

    Xantre x T echnology Inc. i s a worl d-leading suppl ier of a dvanced power ele ctronics and co ntro[...]

  • Page 5

    976-0043-01-02 iii About This Manu al Pu rpose The purpose of this Owner’ s Manual is to p r ovide[...]

  • Page 6

    About this Guide 976-0043-01-02 iv Organiza ti on This gu ide is orga nized int o nine c hapters a n[...]

  • Page 7

    Ab ou t t h is Gu id e v 976-0043-01-02 Appendi x E, “Ove r-Char ge Pr otection” s upplies infor[...]

  • Page 8

    About this Guide 976-0043-01-02 vi R elated Info rmat ion Y ou can fi nd more inform a tion a bout X[...]

  • Page 9

    976-0043-01-02 vii Important Safety Instructions 1. Before using the inverte r , read all i nstructi[...]

  • Page 10

    Import ant S afety Inst ructi ons viii 976-0043-01-02 9. Do not expose this unit to r a in, snow , o[...]

  • Page 11

    976-0043-01-02 ix Im portan t Sa fety Ins tru ctions Exp losi ve g a s prec au tion s - - - - - - - [...]

  • Page 12

    Contents x 976-0043-01-02 Generator start types - - - - - - - - - - - - - - - - - - - - - - - - - - [...]

  • Page 13

    Con tent s 976-0043-01-02 xi Hardw a re / M at erials R equ ired - - - - - - - - - - - - - - - - - -[...]

  • Page 14

    Contents xi i 976-0043-01-02 5 Naviga t ion Navigati ng the Sine Wave Plus - - - - - - - - - - - - -[...]

  • Page 15

    Con tent s 976-0043-01-02 xi ii 12E Max Charge Amps AC - - - - - - - - - - - - - - - - - - - - - - -[...]

  • Page 16

    Contents xi v 976-0043-01-02 23G RY11 Mode - - - - - - - - - - - - - - - - - - - - - - - - - - - - -[...]

  • Page 17

    Con tent s 976-0043-01-02 xv Ch arge St a tus ( Yel low an d G r een) - - - - - - - - - - - - - - - [...]

  • Page 18

    Contents xvi 9 76-0043-01-02 05B Transformer Overte m p - - - - - - - - - - - - - - - - - - - - - - [...]

  • Page 19

    Con tent s 976-0043-01-02 xvii B Configur at ion Se ttings User Me n u Se tti ngs - - - - - - - - - [...]

  • Page 20

    Contents xvi ii 9 76- 0043-01-02 F Mult i-wi re Bran ch Circ uit Wi ring Multi-wir e Branch Ci r cui[...]

  • Page 21

    976-0043-01-02 xi x Figure 1-1 The Sine Wave Plus - - - - - - - - - - - - - - - - - - - - - - - - - [...]

  • Page 22

    Fi g u r e s xx 976-0043-01-02 Figu re 3-3 Dime n sion al D raw in g - - - - - - - - - - - - - - - -[...]

  • Page 23

    Fi g u r e s 976-0043-01-02 xxi Figure 5-13 Advanc ed Setu p Menu Map Part 1 - - - - - - - - - - - -[...]

  • Page 24

    Fi g u r e s xxi i 976-0043-01-02 Figu re A-1 2 Time ver s us Curr ent for the S ine Wa ve P lus 404[...]

  • Page 25

    976-0043-01-02 xxiii Table 2 -1 Recommended M inimu m Safety Ground Wir e a nd DC Discon ne ct Size [...]

  • Page 26

    Ta b l e s xxi v 976-0043-01-02 Table B-3 B a sic S etup Defaul t and Use r Settings for t he Sine W[...]

  • Page 27

    1 Intr oduction Chapter 1, “Introduction” lists and describes the bas ic features and parts of t[...]

  • Page 28

    Introduction 1–2 976-0043-01-02 Ba si c Fea tu res Congrat ulations on your purchase of a Sine W a[...]

  • Page 29

    Ba si c Featu r es 976-0043-01-02 1–3 Fron t P a nel The front of the Sine W ave Pl us has the fol[...]

  • Page 30

    Introduction 1–4 976-0043-01-02 AC S i d e The AC side of the Sine W ave Plus has the followi ng f[...]

  • Page 31

    Ba si c Featu r es 976-0043-01-02 1–5 Emerg ency P ower Off (EPO) Option The Sine W ave Plus of f [...]

  • Page 32

    Introduction 1–6 976-0043-01-02 DC S i de The DC side of the Sine W ave Plus has the followi ng fe[...]

  • Page 33

    Ba si c Featu r es 976-0043-01-02 1–7 Battery T emperatur e Sensor (BTS) A BTS i s provi ded with [...]

  • Page 34

    Introduction 1–8 976-0043-01-02 To p The top of the unit has the following fea tures: • Circui t[...]

  • Page 35

    2 System Configuration Chapter 2, “ System Configuration” con t ai n s i nfo rm ati on to help y[...]

  • Page 36

    System Configuration 2–2 976-0043-01-02 Pr e-Configur a tion Planning Import a nce Pre-c onfigurat[...]

  • Page 37

    Pre-Configurati on Planning 976-0043-01-02 2–3 ❐ Ren ewab le en ergy system s (e .g. , PV a rra [...]

  • Page 38

    System Configuration 2–4 976-0043-01-02 Gener at o r W il l a gen era tor b e use d: ❐ V oltag e[...]

  • Page 39

    Pre-Configurati on Planning 976-0043-01-02 2–5 Loca tion Conside rations Dry Inver ters conta in s[...]

  • Page 40

    System Configuration 2–6 976-0043-01-02 Fire Sa fety All Sine W ave Pl us i nver te r/ch argers m [...]

  • Page 41

    Pre-Configurati on Planning 976-0043-01-02 2–7 Gr ounding Con sidera tions T ypes Whether you are [...]

  • Page 42

    System Configuration 2–8 976-0043-01-02 Inverter Ground ing Requir e ment The inverter/cha rger sh[...]

  • Page 43

    Pre-Configurati on Planning 976-0043-01-02 2–9 Equipment or Chassis Grounding Equipment or chassis[...]

  • Page 44

    System Configuration 2–10 976-0043-01-02 wire m a y be a be tter groundi ng elec trode th a n the [...]

  • Page 45

    Pre-Configurati on Planning 976-0043-01-02 2–11 Gener a tor If th e genera tor is t he main source[...]

  • Page 46

    System Configuration 2–12 976-0043-01-02 More infor m ation Consult your batter y vendor for addit[...]

  • Page 47

    Pre-Configurati on Planning 976-0043-01-02 2–13 Imp orta nt recommenda tion Follow the batte r y c[...]

  • Page 48

    System Configuration 2–14 976-0043-01-02 and inver ter amperage per NEC/CEC guideli ne s. It is re[...]

  • Page 49

    Pre-Configurati on Planning 976-0043-01-02 2–15 inverte rs to meet NEC/CEC c ompliance. T wo amper[...]

  • Page 50

    System Configuration 2–16 976-0043-01-02 Seri es stacked When inv er te rs are “s ta cked ” t [...]

  • Page 51

    Pre-Configurati on Planning 976-0043-01-02 2–17 disco nne ct switches. A sample of thi s warning l[...]

  • Page 52

    System Configuration 2–18 976-0043-01-02 See “Inst al ling the Battery T e mperatur e Sensor (BT[...]

  • Page 53

    Pre-Configurati on Planning 976-0043-01-02 2–19 W ire s iz e for AC connec tions A minimum of #6 A[...]

  • Page 54

    System Configuration 2–20 976-0043-01-02 S table V olt a ge The ge nera tor should provide a stabl[...]

  • Page 55

    Pre-Configurati on Planning 976-0043-01-02 2–21 Manual-st art a nd electr ic-start generators typi[...]

  • Page 56

    System Configuration 2–22 976-0043-01-02 See “Gener ato r St arting Scenarios” on page 7–23 [...]

  • Page 57

    Additional/Optional Equipment Considerations 976-0043-01-02 2–23 DC Condu it Box (DCCB) The DC Con[...]

  • Page 58

    System Configuration 2–24 976-0043-01-02 Fuse Block The Xantrex f use block (TFBxxx) protects the [...]

  • Page 59

    Additional/Optional Equipment Considerations 976-0043-01-02 2–25 Bat te r y St at us Mete r ( TM5 [...]

  • Page 60

    System Configuration 2–26 976-0043-01-02 Remote Mon it ors Three opt ions a re availa ble for remo[...]

  • Page 61

    Additional/Optional Equipment Considerations 976-0043-01-02 2–27 Inverter Cont ro l Module (ICM) T[...]

  • Page 62

    System Configuration 2–28 976-0043-01-02 Ge nera to r St ar t Mo du le (G SM) The G S M is an acc [...]

  • Page 63

    Additional/Optional Equipment Considerations 976-0043-01-02 2–29 240 V ac Applica tion Requ iremen[...]

  • Page 64

    System Configuration 2–30 976-0043-01-02 Re newable E nerg y DC Input Sourc es Renewable energ y ([...]

  • Page 65

    Additional/Optional Equipment Considerations 976-0043-01-02 2–31 PVGFP The PV Ground Fault Protect[...]

  • Page 66

    System Configuration 2–32 976-0043-01-02 Off- Gr id A ppl ica ti on s The Sine W ave Plus c an be [...]

  • Page 67

    Off -Grid Ap plicat ions 976-0043-01-02 2–33 Figur e 2-17 Off-Grid Applic ation – Renew able Ene[...]

  • Page 68

    System Configuration 2–34 976-0043-01-02 Dual-Inver t er Configurat ions (240 V ac) If 240 V ac po[...]

  • Page 69

    Off -Grid Ap plicat ions 976-0043-01-02 2–35 Figur e 2-18 Off-Grid Applic at ion – R enewable En[...]

  • Page 70

    System Configuration 2–36 976-0043-01-02 Gen erato r -O nl y Sy s tems In these ap p lic at ions ,[...]

  • Page 71

    Off -Grid Ap plicat ions 976-0043-01-02 2–37 Figur e 2-19 Off Grid Application - Gener ator -only [...]

  • Page 72

    System Configuration 2–38 976-0043-01-02 Dual-Inver t er Configurat ions If 240 V ac power is requ[...]

  • Page 73

    Off -Grid Ap plicat ions 976-0043-01-02 2–39 Figur e 2-20 Off Grid Application – Gener ato r -on[...]

  • Page 74

    System Configuration 2–40 976-0043-01-02 O n-Gri d App licat ions The Sine W ave Plus c a n be com[...]

  • Page 75

    On-Grid Applications 976-0043-01-02 2–41 Figur e 2-21 On-Grid Application – Backup System using [...]

  • Page 76

    System Configuration 2–42 976-0043-01-02 Dual-Inver t er Configurat ions (240 V ac) If 240 V ac po[...]

  • Page 77

    On-Grid Applications 976-0043-01-02 2–43 Figur e 2-22 On-Grid A pplica tion – Backup System u si[...]

  • Page 78

    System Configuration 2–44 976-0043-01-02 Ener gy Ma nageme nt The Sine W ave Plus c an be programm[...]

  • Page 79

    On-Grid Applications 976-0043-01-02 2–45 Time-of-U se (T OU) M etering Utilit ies use T OU meter i[...]

  • Page 80

    System Configuration 2–46 976-0043-01-02 When using the syste m for TOU mete ring, the system shou[...]

  • Page 81

    On-Grid Applications 976-0043-01-02 2–47 See “21 Grid (AC1) Usage Menu” on page 7–16 for ins[...]

  • Page 82

    2–48[...]

  • Page 83

    3 Installation Chapte r 3, “Installati on” des cribes how to m ount and install the Sine W ave P[...]

  • Page 84

    Insta llation 3–2 976-0043-01-02 Pr e- Instal lat ion Before installi ng the S ine W ave Plu s , r[...]

  • Page 85

    Pre-Inst allation 976-0043-01-02 3–3 Hardw are / Mat er ial s R equ ire d The following materia ls[...]

  • Page 86

    Insta llation 3–4 976-0043-01-02 Remo t e mo ni tor s: ❐ ICM/25 (Inv e rter Control Module wit h[...]

  • Page 87

    Pre-Inst allation 976-0043-01-02 3–5 3. D eterm i ne t he corr ect si ze of bat tery ca bles to us[...]

  • Page 88

    Insta llation 3–6 976-0043-01-02 ❐ Save the ori ginal shipping cart on a nd packing mate r ial s[...]

  • Page 89

    Pre-Inst allation 976-0043-01-02 3–7 Figur e 3-2 Serial Numb er Stick er and Knock out Locations a[...]

  • Page 90

    Insta llation 3–8 976-0043-01-02 Mo unting The Sine W ave Plus c a n be either she lf-mounted or w[...]

  • Page 91

    Pre-Inst allation 976-0043-01-02 3–9 Figur e 3-3 Dimension al Drawing 1" ½" 1½" 1[...]

  • Page 92

    Insta llation 3–10 976-0043-01-02 W all-Mounting W a llboar d is not strong e nough to support t h[...]

  • Page 93

    Pre-Inst allation 976-0043-01-02 3–11 Figur e 3-4 W all-Mount ing Method us ing 2 x 4 ’ s W a l [...]

  • Page 94

    Insta llation 3–12 976-0043-01-02 W a ll Mounti ng using Ply w ood Alterna tively , a half sheet ([...]

  • Page 95

    Pre-Inst allation 976-0043-01-02 3–13 Figur e 3-5 W all Mount ing using Plywood Wal l st u d s 16 [...]

  • Page 96

    Insta llation 3–14 976-0043-01-02 DC Wiring DC wirin g incl udes the following ( describe d in th [...]

  • Page 97

    DC Wiring 976-0043-01-02 3–15 Gr ounding t he DC Sy stem The inverter’ s chassi s grou nd lug (s[...]

  • Page 98

    Insta llation 3–16 976-0043-01-02 Singl e Inverter T o gr ound a si ngle in ve rter: 1. Connect th[...]

  • Page 99

    DC Wiring 976-0043-01-02 3–17 Dual Inv e rters T o groun d a du a l-in v ert er co nf igu ra ti on[...]

  • Page 100

    Insta llation 3–18 976-0043-01-02 Con necting D C Input S ources – Renew able En ergy Con figura[...]

  • Page 101

    DC Wiring 976-0043-01-02 3–19 Figur e 3-9 BTS (R J11) P ort Loc ation and Ins tallation BTS (RJ11)[...]

  • Page 102

    Insta llation 3–20 976-0043-01-02 Con necti ng the B atteries to the In vert er DC terminal connec[...]

  • Page 103

    DC Wiring 976-0043-01-02 3–21 Figure 3-1 1 shows the proper method to att a ch the cable s to the [...]

  • Page 104

    Insta llation 3–22 976-0043-01-02 Procedur e for Single Inverter Systems Before starti ng this pro[...]

  • Page 105

    DC Wiring 976-0043-01-02 3–23 Figur e 3-13 DC Connection s to a Single Inver ter[...]

  • Page 106

    Insta llation 3–24 976-0043-01-02 Procedur e for Dual-Inverter System s Before starti ng this proc[...]

  • Page 107

    DC Wiring 976-0043-01-02 3–25 Figur e 3-14 D C C o nne ct i o ns to Du al I nv e rte rs[...]

  • Page 108

    Insta llation 3–26 976-0043-01-02 AC Wi r i n g This s ection de scribes: • “Accessi ng the AC[...]

  • Page 109

    AC W ir in g 976-0043-01-02 3–27 T able 3-1 AC Disconnect and Wire Sizing Full Pa s s- T h r o u g[...]

  • Page 110

    Insta llation 3–28 976-0043-01-02 Acc essing th e A C T erm inal B lock and G round B ar All AC wi[...]

  • Page 111

    AC W ir in g 976-0043-01-02 3–29 Figur e 3-16 AC Input/Outp ut Wirin g T ermin als AC Terminal Blo[...]

  • Page 112

    Insta llation 3–30 976-0043-01-02 A C W iring fo r Single Inv erter Sy stems There ar e t hre e m [...]

  • Page 113

    AC W ir in g 976-0043-01-02 3–31 W ARNING : Shock H a zar d Auto-s tart genera to rs can star t au[...]

  • Page 114

    Insta llation 3–32 976-0043-01-02 Figur e 3-18 AC Input and O utput Wiring to a Single Inverter wi[...]

  • Page 115

    AC W ir in g 976-0043-01-02 3–33 Install AC Output Wir ing to the Inverter A C Distr ibut ion P an[...]

  • Page 116

    Insta llation 3–34 976-0043-01-02 Make co n ne ctio ns f rom the inv e rter to the inv e rte r pa [...]

  • Page 117

    AC W ir in g 976-0043-01-02 3–35 Install Gener ator Wiring to t he Inverter Generator Discon nect [...]

  • Page 118

    Insta llation 3–36 976-0043-01-02 W ith S tep-down Autotr ansformer and using a 120/ 240 V ac Gene[...]

  • Page 119

    AC W ir in g 976-0043-01-02 3–37 b) from the neut r al in the gener a tor disconnect to the invert[...]

  • Page 120

    Insta llation 3–38 976-0043-01-02 Install Utility W iring to the Inverter Input (O n-Grid Applicat[...]

  • Page 121

    Optional Equipment 976-0043-01-02 3–39 Figur e 3-21 Utility Wiring to the Inverter Input Op tio na[...]

  • Page 122

    Insta llation 3–40 976-0043-01-02 Installi ng t he ISC-S Cable T o in sta ll t he ISC -S c a ble o[...]

  • Page 123

    Optional Equipment 976-0043-01-02 3–41 Remo te Moni t ori ng Optio ns The Sine W ave Plus c an be [...]

  • Page 124

    Insta llation 3–42 976-0043-01-02 Aux iliary L oad Module (ALM) The ALM can be used to s ignal loa[...]

  • Page 125

    Optional Equipment 976-0043-01-02 3–43 Emer gency Po wer Off (EPO ) The Sine W ave Plus ha s an EP[...]

  • Page 126

    3–44[...]

  • Page 127

    4 Fu nct ion al T est Chapter 4, “ Functional T est ” explains how to conduct a functional test [...]

  • Page 128

    Functional T e st 4–2 976-0043-01-02 Basic Functional T est The foll owing st eps will co mplete a[...]

  • Page 129

    Basic Functional T e st 976-0043-01-02 4–3 T urn in g ON the I n ver te r T o t urn o n th e inver[...]

  • Page 130

    Functional T e st 4–4 976-0043-01-02 A C V oltage Check T o perform an AC voltag e check: 1. W ith[...]

  • Page 131

    Basic Functional T e st 976-0043-01-02 4–5 Confirm ing Inver ter Oper at ion T o c onfirm th at th[...]

  • Page 132

    4–6[...]

  • Page 133

    5 Naviga tion Chapte r 5, “Navigation” explains how to navigate through the Sine W ave Plus Inve[...]

  • Page 134

    Navigation 5–2 976-0043-01-02 Navig ati n g the Sine W ave Plus The Sine W ave Plus is pr ogrammed[...]

  • Page 135

    Inverter Control Module F eatures 976-0043-01-02 5–3 The In v erte r Contro l Mo dule (I CM) The I[...]

  • Page 136

    Navigation 5–4 976-0043-01-02 Displa y contra st T o change the displ a y contra st, use a sm all [...]

  • Page 137

    Inverter Control Module F eatures 976-0043-01-02 5–5 Menu Heading Buttons The Menu Heading push-bu[...]

  • Page 138

    Navigation 5–6 976-0043-01-02 Set P oint Buttons The SET P OINT buttons chang e the value of a par[...]

  • Page 139

    Men u Map 976-0043-01-02 5–7 Menu Map Introduc tion The menu system conta ins three main menu maps[...]

  • Page 140

    Navigation 5–8 976-0043-01-02 User Menu (01-07) The USER MENU allows access to the daily operat io[...]

  • Page 141

    Men u Map 976-0043-01-02 5–9 Figur e 5-10 Use r Me nu Map - P ar t 2[...]

  • Page 142

    Navigation 5–10 976-0043-01-02 Basic Setup Menu (10-14) The BASIC SETUP MENU follows the User Menu[...]

  • Page 143

    Men u Map 976-0043-01-02 5–11 Figur e 5-12 Basic Setup M enu M ap P art 2[...]

  • Page 144

    Navigation 5–12 976-0043-01-02 Advance d Setup Menu (20-27) The ADV ANCED SETUP MENU contains spec[...]

  • Page 145

    Men u Map 976-0043-01-02 5–13 Figur e 5-14 Advan c ed Setu p M enu M ap P art 2[...]

  • Page 146

    Navigation 5–14 976-0043-01-02 Figur e 5-15 Com plet e Us er Me nu Ma p[...]

  • Page 147

    Men u Map 976-0043-01-02 5–15 Figur e 5-16 Com plet e Ba sic Setup Men u Ma p[...]

  • Page 148

    Navigation 5–16 976-0043-01-02 Figur e 5-17 Comple te Adva nced Setup Menu M ap[...]

  • Page 149

    6 Basic Setup Pr ogr amming Chapter 6, “ Basic Setup Program ming” explains how to program the S[...]

  • Page 150

    Basic Setup Pr o gramming 6–2 976-0043-01-02 B asic Se tup Summ ary Check Default s The following [...]

  • Page 151

    Basic S e tup Summary 976-0043-01-02 6–3 1 1C Low Batt ery Cut Out Vdc 11. 0 to 33.9 22.0 32.0 to [...]

  • Page 152

    Basic Setup Pr o gramming 6–4 976-0043-01-02 14C Push GEN for factory defa ults Push GEN for facto[...]

  • Page 153

    Basic S e tup Summary 976-0043-01-02 6–5 12E Max Char ge Amps AC 01 to 30 30 01 to 30 30 pa ge 6?[...]

  • Page 154

    Basic Setup Pr o gramming 6–6 976-0043-01-02 T able 6-3 Basic Set up Menu Defau lt Settings for th[...]

  • Page 155

    Basic S e tup Summary 976-0043-01-02 6–7 13 AC Inputs Menu See “13 AC Inputs Menu ” on page 6?[...]

  • Page 156

    Basic Setup Pr o gramming 6–8 976-0043-01-02 Before Y ou Beg in P rogramming Some items must be pr[...]

  • Page 157

    Before Y ou Begin Programming 976-0043-01-02 6–9 Ba sic Setup Proces s The Basic Setup procedure i[...]

  • Page 158

    Basic Setup Pr o gramming 6–10 976-0043-01-02 Ac cess ing th e Bas ic Se tu p Men u T o acces s th[...]

  • Page 159

    Menu Item D escri pt ions 976-0043-01-02 6–11 Menu It em Descr ipt io ns 10 Time of D ay Setup Men[...]

  • Page 160

    Basic Setup Pr o gramming 6–12 976-0043-01-02 10C Se t Seconds T o se t t he seco n d di spl ay: 1[...]

  • Page 161

    Menu Item D escri pt ions 976-0043-01-02 6–13 This volta ge level is use d to indicat e that the b[...]

  • Page 162

    Basic Setup Pr o gramming 6–14 976-0043-01-02 11E Search W atts This m enu item s ets t he inve rt[...]

  • Page 163

    Menu Item D escri pt ions 976-0043-01-02 6–15 The sensiti vity control shoul d be adjuste d so tha[...]

  • Page 164

    Basic Setup Pr o gramming 6–16 976-0043-01-02 Multi-St age Charging Pr ocess The c h arging c ycle[...]

  • Page 165

    Menu Item D escri pt ions 976-0043-01-02 6–17 Absorpt ion Stage Absorption ch a r ge is the secon [...]

  • Page 166

    Basic Setup Pr o gramming 6–18 976-0043-01-02 Equalize Charg ing the Batteries Many ba ttery man u[...]

  • Page 167

    Menu Item D escri pt ions 976-0043-01-02 6–19 12 Battery Charg ing Menu Batte ry C har ging parame[...]

  • Page 168

    Basic Setup Pr o gramming 6–20 976-0043-01-02 12B Bulk V olts DC This i s the voltage level at whi[...]

  • Page 169

    Menu Item D escri pt ions 976-0043-01-02 6–21 The following sett ings ( Ta b l e 6 - 5 ) are guid [...]

  • Page 170

    Basic Setup Pr o gramming 6–22 976-0043-01-02 12E Max Char ge Amps AC This is the maximum AC amper[...]

  • Page 171

    Menu Item D escri pt ions 976-0043-01-02 6–23 12F Bulk Done Amps AC This is the A C cu rr ent th r[...]

  • Page 172

    Basic Setup Pr o gramming 6–24 976-0043-01-02 12G EQ VDC Done Timer Th is is th e ma x i m u m ti [...]

  • Page 173

    Menu Item D escri pt ions 976-0043-01-02 6–25 12H Max Bulk/EQ Timer h :m This is the maximum time [...]

  • Page 174

    Basic Setup Pr o gramming 6–26 976-0043-01-02 T emp e rat u re com p en sat ion cal cu lat i on s [...]

  • Page 175

    Menu Item D escri pt ions 976-0043-01-02 6–27 13A Grid (A C1) A mps AC This i s the maximum amount[...]

  • Page 176

    Basic Setup Pr o gramming 6–28 976-0043-01-02 13C In put Upper Limit V AC This menu it em se ts th[...]

  • Page 177

    Menu Item D escri pt ions 976-0043-01-02 6–29 14 Sav e/R es tore Se tti n gs Menu This m enu provi[...]

  • Page 178

    Basic Setup Pr o gramming 6–30 976-0043-01-02 14C Push GEN f or F actory Defaults This m enu item [...]

  • Page 179

    7 Advanced Setup Chapter 7, “ Advanced Setup” explains how to progra m the Sine W ave Plus Inver[...]

  • Page 180

    Advanced Setup 7–2 976-0043-01-02 Adv anced Setu p Summ ary Check Default s The following model-s [...]

  • Page 181

    Advanced Setup Su mmar y 976-0043-01-02 7–3 21C Grid Usa ge End h:m 00:00 to 23: 50 21:00 00:00 to[...]

  • Page 182

    Advanced Setup 7–4 976-0043-01-02 25A R Y7 Mode GS RN 1 RN2 GS GS RN1 RN2 GS page 7–30 25B Ge n [...]

  • Page 183

    Advanced Setup Su mmar y 976-0043-01-02 7–5 T able 7-2 Adv anced Setup Defau lt Settings f or the [...]

  • Page 184

    Advanced Setup 7–6 976-0043-01-02 24B Gen Run T ime St op h:m 00 :00 to 23: 50 08:00 00:00 to 23:5[...]

  • Page 185

    Advanced Setup Su mmar y 976-0043-01-02 7–7 27A Pus h INV no w to save Se ttings Push INV now to S[...]

  • Page 186

    Advanced Setup 7–8 976-0043-01-02 23 AL M Rela ys Menu See “23 ALM Relays Menu” on page 7–19[...]

  • Page 187

    Advanced Setup Su mmar y 976-0043-01-02 7–9 26A Load S ta rt Amps AC 00 to 63 45 pa ge 7–38 26B [...]

  • Page 188

    Advanced Setup 7–10 976-0043-01-02 Before Y ou Be g in A d vanced Pr ogramming The Sine W ave Plus[...]

  • Page 189

    Acce ssi ng the Advanced Se tup Men u 976-0043-01-02 7–11 Acce ss ing th e Adv an ced Se tu p Me n[...]

  • Page 190

    Advanced Setup 7–12 976-0043-01-02 5. From here you can, eith er: a) Press the butt on to move for[...]

  • Page 191

    Menu Item D escri pt ions 976-0043-01-02 7–13 Menu It em Descr ipt io ns 20 Sile nt Set up Menu Th[...]

  • Page 192

    Advanced Setup 7–14 976-0043-01-02 Silent Mode will be gin after the char ge routine has finis he [...]

  • Page 193

    Menu Item D escri pt ions 976-0043-01-02 7–15 Silent Mode te r minate s ba sed on time 20D M ust F[...]

  • Page 194

    Advanced Setup 7–16 976-0043-01-02 20D Must Float Time Min This m enu item s ets t he mi nim um am[...]

  • Page 195

    Menu Item D escri pt ions 976-0043-01-02 7–17 21A Grid Usag e This menu i tem allo ws you to sele [...]

  • Page 196

    Advanced Setup 7–18 976-0043-01-02 The clock is in a 24-hour f or mat (00: 00 to 23:59 hours) . Gu[...]

  • Page 197

    Menu Item D escri pt ions 976-0043-01-02 7–19 22A High X f er (HBX ) V DC This m enu is us ed to s[...]

  • Page 198

    Advanced Setup 7–20 976-0043-01-02 RY 11 R Y1 1 , when ERRO R is se le ct ed , i s use d as an inv[...]

  • Page 199

    Menu Item D escri pt ions 976-0043-01-02 7–21 23E R Y10 Vdc DeEnergized This m enu item se ts the [...]

  • Page 200

    Advanced Setup 7–22 976-0043-01-02 Figur e 7-3 Relay 11 Wiring Example t o Dual Inverters w ith Co[...]

  • Page 201

    Menu Item D escri pt ions 976-0043-01-02 7–23 Gen era tor St ar ti n g Sc e nar i o s The Sine W a[...]

  • Page 202

    Advanced Setup 7–24 976-0043-01-02 The g enerator will conti nue to r un unless one of the followi[...]

  • Page 203

    Menu Item D escri pt ions 976-0043-01-02 7–25 If se t poin t RN1 is selected in 25A R Y7 Mode , th[...]

  • Page 204

    Advanced Setup 7–26 976-0043-01-02 24 Gene rat or T ime rs Men u This m enu heading sets parameter[...]

  • Page 205

    Menu Item D escri pt ions 976-0043-01-02 7–27 24A Gen Run Time Star t h:m This m enu item s ets t [...]

  • Page 206

    Advanced Setup 7–28 976-0043-01-02 24D Quiet Time End h:m This menu item ends the quie t time, aft[...]

  • Page 207

    Menu Item D escri pt ions 976-0043-01-02 7–29 24H RN2/Max Gen Run h:m This menu item set s the lim[...]

  • Page 208

    Advanced Setup 7–30 976-0043-01-02 Gu id e li n e s f o r se tt i n g th is m e n u it e m : • W[...]

  • Page 209

    Menu Item D escri pt ions 976-0043-01-02 7–31 RN1 This selec tion pr ovides a run signal by holdin[...]

  • Page 210

    Advanced Setup 7–32 976-0043-01-02 R Y8 Relay (GS and RN1 only) The R Y8 is energi zed (COM a nd N[...]

  • Page 211

    Menu Item D escri pt ions 976-0043-01-02 7–33 Figur e 7-7 Wirin g examples of H onda™ and Onan?[...]

  • Page 212

    Advanced Setup 7–34 976-0043-01-02 Figur e 7-8 RY 7 a n d RY 8 T i m i n g D i a g r a m The gener[...]

  • Page 213

    Menu Item D escri pt ions 976-0043-01-02 7–35 Figur e 7-9 R Y 7/R Y8 Seq uence of Events for RN1 o[...]

  • Page 214

    Advanced Setup 7–36 976-0043-01-02 Figur e 7-10 R Y7/R Y8 Sequence of Events for GS Se lec tion[...]

  • Page 215

    Menu Item D escri pt ions 976-0043-01-02 7–37 25B Gen W arm-up Seconds/minutes This menu item set [...]

  • Page 216

    Advanced Setup 7–38 976-0043-01-02 26 Ge n Auto Ru n Setup M enu Menu Heading 26 Ge n Auto R un Se[...]

  • Page 217

    Menu Item D escri pt ions 976-0043-01-02 7–39 26F 15 Min Start V olts DC This m enu item s ets t h[...]

  • Page 218

    Advanced Setup 7–40 976-0043-01-02 27B Push GEN t o Restor e Sett ings This m enu item pr ovides t[...]

  • Page 219

    8 Op erat io n Chapte r 8, “Ope ration” explains how to operate t he Sine W ave Plus Invert er/C[...]

  • Page 220

    Operat i on 8–2 976-0043-01-02 Op erat ing th e Sine W ave Plus User Me n u Th e Sine W ave Plus u[...]

  • Page 221

    Operational Status Indicators 976-0043-01-02 8–3 Op erat iona l St atus Indi c at ors The Sine W a[...]

  • Page 222

    Operat i on 8–4 976-0043-01-02 Inverter Operat ion Status (Y ellow) There ar e two yellow LEDs to [...]

  • Page 223

    Operational Status Indicators 976-0043-01-02 8–5 A C Input Status (Green) S tatus LEDs There are t[...]

  • Page 224

    Operat i on 8–6 976-0043-01-02 Charg e Status (Y ellow and G reen) Char ging indicat or s There ar[...]

  • Page 225

    Operational Status Indicators 976-0043-01-02 8–7 Operatio nal Stat us Ind ic ation (Red and Y ello[...]

  • Page 226

    Operat i on 8–8 976-0043-01-02 Erro r LE D Re s e t Reset T o reset the inver ter after resol ving[...]

  • Page 227

    Operational Status Indicators 976-0043-01-02 8–9 LED Summ ary Ta b l e 8 - 1 s um m arize s the LE[...]

  • Page 228

    Operat i on 8–10 976-0043-01-02 E R RO R LE D (red) No error has been de te ct ed . A n Invert er [...]

  • Page 229

    T he User Men u Sum mary 976-0043-01-02 8–11 The Us er Me nu S umma ry The User Menu provide s all[...]

  • Page 230

    Operat i on 8–12 976-0043-01-02 Xant re x T ech I nc 5916 195t h St NE Info. Di s pla y ed Read O [...]

  • Page 231

    T he User Men u Sum mary 976-0043-01-02 8–13 05F Exter nal er r (sta cked) NO Y E S Rea d On ly NO[...]

  • Page 232

    Operat i on 8–14 976-0043-01-02 Ac cess ing th e Us er Me nu T o dire c tly access t he 01A Invert[...]

  • Page 233

    User Menu D escri pt ion 976-0043-01-02 8–15 User Menu Desc r iption 01 Inv erter ON /OFF Menu The[...]

  • Page 234

    Operat i on 8–16 976-0043-01-02 01B EQ Charg e OFF ON OFF When OFF is selected in the menu, the in[...]

  • Page 235

    User Menu D escri pt ion 976-0043-01-02 8–17 01D Bypass M ode The Bypass Modeclose s the inte rnal[...]

  • Page 236

    Operat i on 8–18 976-0043-01-02 02A Generat or The 02A Gene r ator menu i tem provide s three s et[...]

  • Page 237

    User Menu D escri pt ion 976-0043-01-02 8–19 Menu items 02B through 02F wil l indic at e “NO” [...]

  • Page 238

    Operat i on 8–20 976-0043-01-02 03 Time Of D ay Menu Menu Heading 03 T im e O f D a y displa ys in[...]

  • Page 239

    User Menu D escri pt ion 976-0043-01-02 8–21 Press R e s et f or Factor y De fa ul t s In addition[...]

  • Page 240

    Operat i on 8–22 976-0043-01-02 04 Mete rs Men u The Meters Menu provide s information about syst [...]

  • Page 241

    User Menu D escri pt ion 976-0043-01-02 8–23 04B Batt er y Comp Vdc This m enu item di splay shows[...]

  • Page 242

    Operat i on 8–24 976-0043-01-02 04G Grid (A C1) V olt s A C This m enu item di splays the AC i npu[...]

  • Page 243

    User Menu D escri pt ion 976-0043-01-02 8–25 05 Erro r Caus es Me nu Detect e d inv erter e rrors [...]

  • Page 244

    Operat i on 8–26 976-0043-01-02 05C Heatsink O ver temp If “ yes” is vis ible in t his displ a[...]

  • Page 245

    User Menu D escri pt ion 976-0043-01-02 8–27 05E High Bat t ery V oltag e If “Y es” is displ a[...]

  • Page 246

    Operat i on 8–28 976-0043-01-02 05H Gen F ailed to Start If “Y es” is displ ayed, the automati[...]

  • Page 247

    User Menu D escri pt ion 976-0043-01-02 8–29 06A Bypass M ode Selected If “Y es” is displ ayed[...]

  • Page 248

    Operat i on 8–30 976-0043-01-02 06E EQ Charg e Selected If “Y es” is displ ayed, the char ge r[...]

  • Page 249

    User Menu D escri pt ion 976-0043-01-02 8–31 07B R Y8 (GSM) Ener gized If “Y e s” is displaye [...]

  • Page 250

    8–32[...]

  • Page 251

    9 T r oubl esho oti ng Chapter 9, “ T roubleshooting” contains information and procedures for s [...]

  • Page 252

    T roubleshooting 9–2 976-0043-01-02 Invert er T rouble sho otin g If the red ERROR LED illum inate[...]

  • Page 253

    Inverter T roubleshooting 976-0043-01-02 9–3 Low AC power output or Low surge powe r INVER T LED i[...]

  • Page 254

    T roubleshooting 9–4 976-0043-01-02 Batt er y Charger T roubles ho oti ng If the red ERROR LED ill[...]

  • Page 255

    Battery Charger T r oubleshooting 976-0043-01-02 9–5 Charg er drops off befo re full cha r g ing h[...]

  • Page 256

    T roubleshooting 9–6 976-0043-01-02 Batte ries be ing c harge d abov e the Bulk/ Float sett ing. I[...]

  • Page 257

    Er ror Ca use s 976-0043-01-02 9–7 Er ror Ca us es This ta b le refers to 05 Er r or Cau ses Me nu[...]

  • Page 258

    T roubleshooting 9–8 976-0043-01-02 05G In pu t Re lay Fai lur e The AC tr a nsfe r rela y is bad [...]

  • Page 259

    A Inverter Spec ificati o ns Appendix A, “ Inverter Specifi cations” pr ovides the elec trical a[...]

  • Page 260

    Inve rter Sp ecific atio ns A–2 976-0043-01-02 Elec t ric al Sp ecifi c at ions AC Input V olta ge[...]

  • Page 261

    Elec trical Spe cifications 976-0043-01-02 A– 3 AC Input V ol tage (no m inal) 120 V ac 12 0 V ac [...]

  • Page 262

    Inve rter Sp ecific atio ns A–4 976-0043-01-02 Me chani ca l Speci fic atio ns Oper ati ng T emper[...]

  • Page 263

    Mecha nic al Spe cificatio ns 976-0043-01-02 A– 5 Operati ng T emperature R ange SPECIFIED (w il l[...]

  • Page 264

    Inve rter Sp ecific atio ns A–6 976-0043-01-02 Theor y of Op erat ion The Sine W ave Plu s employs[...]

  • Page 265

    Th eo r y o f O p e ra t io n 976-0043-01-02 A– 7 The inver te r runs in two basi c formats: as a [...]

  • Page 266

    Inve rter Sp ecific atio ns A–8 976-0043-01-02 P ower V ersu s E fficiency There are two pr imary [...]

  • Page 267

    P ower V ersus E ffici ency 976-0043-01-02 A– 9 Figure A-4 Sine W ave Plus E fficiency Cu rve for [...]

  • Page 268

    Inve rter Sp ecific atio ns A–10 976-0043-01-02 Figure A-5 Sine W ave Plus E fficiency Curve fo r [...]

  • Page 269

    P ower V ersus E ffici ency 976-0043-01-02 A– 11 Figure A-7 Sine W ave Plus E fficiency Curve fo r[...]

  • Page 270

    Inve rter Sp ecific atio ns A–12 976-0043-01-02 In vert er Cap ac i ty v ersu s T empe rature The [...]

  • Page 271

    T ime ve rsus Cu rrent 976-0043-01-02 A– 13 Tim e versus Current Load s pr esen ted to the i nv er[...]

  • Page 272

    Inve rter Sp ecific atio ns A–14 976-0043-01-02 Figur e A-10 T i m e v er su s C u rre n t f or t [...]

  • Page 273

    T ime ve rsus Cu rrent 976-0043-01-02 A– 15 Figur e A-12 T i m e v er su s C u rre n t f or t h e [...]

  • Page 274

    A–16[...]

  • Page 275

    B Con figuration Settings Appendix B, “C onf iguration Settings” provides workshee ts for progra[...]

  • Page 276

    Configuration Settings B–2 976- 0043-01-02 Us er Me nu Se ttin gs Ta b l e B - 1 provide s a list [...]

  • Page 277

    Us er Me nu Se tt ing s 976-0043-01-02 B–3 Ph 1-80 0-446-6 180 www .xant rex. co m Press reset for[...]

  • Page 278

    Configuration Settings B–4 976- 0043-01-02 06 St atu s Menu See “06 Sta tus Menu ” on page 8?[...]

  • Page 279

    Basi c Setup Menu 976-0043-01-02 B–5 Ba si c S et u p M e n u Ta b l e B - 2 provide s a list of B[...]

  • Page 280

    Configuration Settings B–6 976- 0043-01-02 12I T e mp Comp Lea dA cid Ni Ca d Le adAc id Le adAc i[...]

  • Page 281

    Basi c Setup Menu 976-0043-01-02 B–7 12 Batte ry Char ging Menu See “12 Batte ry Char ging Menu [...]

  • Page 282

    Configuration Settings B–8 976- 0043-01-02 T able B-4 Basic Setup Defau lt and User Settings fo r [...]

  • Page 283

    Basi c Setup Menu 976-0043-01-02 B–9 14A Pus h INV no w to save se ttings Push INV now to Save Set[...]

  • Page 284

    Configuration Settings B–10 976- 0043-01-02 Adv anc ed Se tup Me nu Ta b l e B - 5 provide s a lis[...]

  • Page 285

    Advanced Setup Menu 976-0043-01-02 B–11 24 Generator T imers Menu See “24 Generat or Timers Menu[...]

  • Page 286

    Configuration Settings B–12 976- 0043-01-02 26 G Read LBCO 30 se c Sta rt L BCO sett ing (1 1C) 22[...]

  • Page 287

    Advanced Setup Menu 976-0043-01-02 B–13 23A R Y9 Vdc Ene rgized 22.1 t o 35.5 26.0 44. 2 t o 71.0 [...]

  • Page 288

    Configuration Settings B–14 976- 0043-01-02 26D 24- hr S tart V olts DC 10.0 to 3 5.5 24.6 20.0 t [...]

  • Page 289

    Advanced Setup Menu 976-0043-01-02 B–15 22B L o w X f e r ( LB X ) V dc 3 2 . 2 to 67 . 8 46 . 0 2[...]

  • Page 290

    Configuration Settings B–16 976- 0043-01-02 26B L o a d St ar t De l a y M in 0 0 . 0 to 25 . 5 05[...]

  • Page 291

    C Battery Information Appendix C, “Battery Inf ormation” supplies general informa tion a bo ut b[...]

  • Page 292

    Bat tery In formation C–2 976-0043-01-02 Introducti on Batte r ies Batteri es are ava ilable i n d[...]

  • Page 293

    Batt ery T ype s 976-0043-01-02 C– 3 Seal ed Ba tteries (G el and A GM) Descri ption Gel Cell and [...]

  • Page 294

    Bat tery In formation C–4 976-0043-01-02 Other options Another option for 2 4 volt (only) a lkalin[...]

  • Page 295

    Bat tery Ban k Sizi ng 976-0043-01-02 C– 5 Depth of disc ha r ge In gen e ral, the bat tery bank s[...]

  • Page 296

    Bat tery In formation C–6 976-0043-01-02 T ime an d power The le ngth of ti me a load is ope rated[...]

  • Page 297

    Bat tery Ban k Sizi ng 976-0043-01-02 C– 7 Amp Hour Example W orksheet Complet e the following ste[...]

  • Page 298

    Bat tery In formation C–8 976-0043-01-02 Battery bank size wor ks heet Calcul ation T o cal cul a [...]

  • Page 299

    Battery C onfigurations 976-0043-01-02 C– 9 Ba tt er y Co nf igur at ions The batte r y bank must [...]

  • Page 300

    Bat tery In formation C–1 0 976-0043-01-02 W iring Batt eries in P arallel Ef fect W ir ing the ba[...]

  • Page 301

    Battery C onfigurations 976-0043-01-02 C– 11 W iring Batt eries in Series- P a rallel Ef fect W ir[...]

  • Page 302

    Bat tery In formation C–1 2 976-0043-01-02 Connect to in ve rter T o con nec t to th e in vert er:[...]

  • Page 303

    Battery Maintenance 976-0043-01-02 C– 13 Batt er y Main te nan ce Mainte na nce strate gy T o get [...]

  • Page 304

    Bat tery In formation C–1 4 976-0043-01-02 T emperatur e compensati on is ba sed on b attery type?[...]

  • Page 305

    Battery Maintenance 976-0043-01-02 C– 15 Equ a li za ti o n C ha rgi ng Purpose An e qua liz e cha[...]

  • Page 306

    Bat tery In formation C–1 6 976-0043-01-02 Gene ral M aintenance W a ter Levels Floode d le ad ac [...]

  • Page 307

    Battery Maintenance 976-0043-01-02 C– 17 S tate of C harge The ba ttery’ s state - of-char ge s [...]

  • Page 308

    C–1 8[...]

  • Page 309

    D Gene rators Appendix D, “ Generators” s upplies information about generator starting. This inf[...]

  • Page 310

    Ge ne ra t ors D–2 976-0043-01-02 T w o-Wire Star t Ci rcui ts T wo-wire s tarting generator s are[...]

  • Page 311

    T hree -Wire St art Ci rcuit s 976-0043-01-02 D– 3 Ona n™ 3- W i re T y pe G ene rat ors Most On[...]

  • Page 312

    D–4[...]

  • Page 313

    E Over -Char ge Pr otec tion Appendix E, “Over-Charge Protection” supplies information about opt[...]

  • Page 314

    Over -Charge Protection E–2 976-0043-01-02 O verv o lt ag e Pro tect ion u sing a Ch arg e Cont ro[...]

  • Page 315

    Diversion Load Control 976-0043-01-02 E–3 Div ersi on L oad C on trol DC generato r devices , such[...]

  • Page 316

    E–4[...]

  • Page 317

    F Mu lt i - wire Bra n c h Cir cuit W iring Appendix F , “Multi-wire B ranch Circuit Wiring” s u[...]

  • Page 318

    Mult i-wire Branch C ircuit Wi ring F–2 976-0043-01-02 Mult i- wi re Bran ch Ci rcui ts Proble m A[...]

  • Page 319

    Multi- wire B ran ch Circ uits 976-0043-01-02 F– 3 Figure F-2 Multi -wire B ranch Circ uit Wiri ng[...]

  • Page 320

    Mult i-wire Branch C ircuit Wi ring F–4 976-0043-01-02 Iden t ify ing Mu lt i- wi re Branch Ci rcu[...]

  • Page 321

    Corr ectin g Multi- wire B ranch Ci rcui t Wirin g 976-0043-01-02 F– 5 Co rrect in g Mu lt i- wi r[...]

  • Page 322

    Mult i-wire Branch C ircuit Wi ring F–6 976-0043-01-02 Figure F-5 Using a St ep-down Aut otransfor[...]

  • Page 323

    G Em e r genc y P owe r Off Swi t c hes Appendix G , “ Emergency Pow er O ff S w i t c h e s ” s[...]

  • Page 324

    Emerg ency P owe r Off Swi tches G–2 976-0043-01-02 Th e Purpo se of an EP O swit ch In t he e ve [...]

  • Page 325

    The Purpose o f an EPO sw itch 976-0043-01-02 G– 3 The intent of this featur e is to provid e thre[...]

  • Page 326

    Emerg ency P owe r Off Swi tches G–4 976-0043-01-02 the buil ding a t a readily a c cessibl e loca[...]

  • Page 327

    976-0043-01-02 H– 1 Glossary “Gloss ary” conta ins a glossar y of technic al terms used in thi[...]

  • Page 328

    H–2 976-0043-01-02 A conduct ive medium in whic h the flow of elect ricit y takes plac e; this is [...]

  • Page 329

    976-0043-01-02 H– 3 A voltag e drop c aus ed by resista nce in wire during tr a nsmiss ion of elec[...]

  • Page 330

    H–4 976-0043-01-02 A group of electr ical de vic es, such as bat teries or PV modul es, wi re d to[...]

  • Page 331

    976-0043-01-02 H– 5 Abbrevi ations and A crony ms AC Alte rnatin g Curren t ACCB AC Condui t Box A[...]

  • Page 332

    H–6 976-0043-01-02 LCD Liq uid Crys tal Disp lay LED Light Em it ting Diode NEC Nati ona l Electri[...]

  • Page 333

    976-0043-01-02 I–1 W arr anty and Pr odu ct Information Wa r r a n t y Wha t does t his warr a nty[...]

  • Page 334

    I–2 976-0043-01-02 Direc t returns may be perfor m ed accor ding to the Xantre x Return Materia l [...]

  • Page 335

    Retur n Materi al Aut horiza tion P ol icy 976-0043-01-02 I–3 MERCHANT ABILITY OR F ITNESS FO R A [...]

  • Page 336

    I–4 976-0043-01-02 Return Proced ure 1. Package the unit safel y , preferabl y using the origina l[...]

  • Page 337

    Information About Y our S y stem 976-0043-01-02 I–5 Inf ormat ion Ab out Y o ur Sys tem As soon as[...]

  • Page 338

    I–6[...]

  • Page 339

    Index 976-0043-01-02 IX –1 3- to-2 W ire Convert er s D–3 AC 3–26 AC output requi rements, det[...]

  • Page 340

    Index IX–2 976-0043- 01-02 Generato r E xer ci sin g 7–25 Genera tor S ta rt Module s ee GSM gen[...]

  • Page 341

    Index 976-0043-01-02 IX –3 saf e ty in s t r uc t io n s i i – v ii– ? ? se ria l number I–5[...]

  • Page 342

    Index IX–4 976-0043- 01-02[...]

  • Page 343

    [...]

  • Page 344

    Xant rex Tec hno logy Inc . 8999 Nelson Wa y Bur nab y, Br itish Co lum bia Can ada V5 A 4B5 800 670[...]